background image

Page 7 of 11 

Edition 07/21/2008 

INNOTECH  

INNOTECH LOCK

 

INNO

TECH

   

LOCK-11

 

 
 

FASTENING ON THE STEEL GIRDER

 

 
 
 
 
 
 

 

Minimum steel cross section 5 mm 

 

 

Tighten counter nuts.  

 

 

Check for firm seat. 

 
 
 
 
 
 
 
 
 
 
 
 

You must contact the manufacturer if there are deviating conditions. 

 
 
 

Summary of Contents for LOCK-13

Page 1: ...van de veiligheidsinrichting is pas toegestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztons gi bere...

Page 2: ...NOTECH LOCK 11 13 INSTRUCTIONS FOR INSTALLATION AND USE TABLE OF CONTENTS 1 SAFETY INSTRUCTIONS PAGES 3 4 2 GENERAL INFORMATION PAGE 5 3 INSTALLATION LOCK 11 receptacle sleeve PAGES 6 7 4 APPLICATION...

Page 3: ...ting the work you must ensure that no objects can fall to the ground from the work site The area below the work site sidewalk etc must be kept clear The fitters must ensure that the ground is suited f...

Page 4: ...n etc If in doubt relative to safe function of the anchorage point it must be taken out of service and sent to the manufacturer for inspection At least once a year an expert must check the complete sa...

Page 5: ...oncrete and steel SIGNS AND MARKINGS Type designation INNOTECH LOCK Number s of the applicable standard s EN 795A Name or logo of the manufacturer reseller INNOTECH Manufacturer s serial number and ye...

Page 6: ...in INNOTECH LOCK 11 in accordance with the instructions for installation and use provided by the adhesive manufacturer Check for firm seat If in doubt about the substrate or the fastening strictly ens...

Page 7: ...7 21 2008 INNOTECH INNOTECH LOCK INNOTECH LOCK 11 FASTENING ON THE STEEL GIRDER Minimum steel cross section 5 mm Tighten counter nuts Check for firm seat You must contact the manufacturer if there are...

Page 8: ...keep it depressed Slide the LOCK 13 into the receptacle sleeve until it hits the spring and then release the unlock unlock tab Now press the anchorage point deeper into the receptacle sleeve until an...

Page 9: ...ety system confirms that the installation work has been executed properly in accordance with the state of the art and in accordance with the manufacturer s instructions for installation and use The sa...

Page 10: ...e instructions for installation and use inspection logs etc is Overview diagram showing the position of the anchorage devices Draw in the areas where there is a break through hazard The maximum limit...

Page 11: ...inst falling Inspection in accordance with manufacturer s specifications Expiration date Annual inspection performed Not checked no authorization ANCHORAGE POINT INNOTECH LOCK 13 No deformation The at...

Reviews: