InnoSenT SMT mountable Series User Manual Download Page 8

  

Experience and Reliability in Radar Technology 

 

 

 

CONFIDENTIAL AND PROPRIETARY

 

The information contained in this document shall remain the sole and exclusive property of InnoSenT GmbH and shall not be 

disclosed by the recipient to third parties without prior consent of InnoSenT in writing.

 

 

 

ORDER INFORMATION

 

 

 

SMR

 

www.InnoSenT.de

 

antenna

 

 

sy

ste

m

 p

atte

rn

  

121°

 x

 111°

 

(1

 x 1
 Pa

tch

)

 

 

sy

ste

m

 p

atte

rn

     

43°
 x

 116°

 

(1

 x 4
 Pa

tch

)

 

SMR-314

 

 

 

SMR-334

 

 

 

 
 

 

 

 

 

 

APPROVAL

 

This Data Sheet contains the technical specifications of the described product. Changes of the specification must 
be in written form. All previous versions of this Data Sheet are no longer valid.

 

 

 

VERSION

 

DATE

 

COMMENT

 

1.0

 

13.04.2016

 

initial release

 

1.1

 

26.07.2016

 

data matrix code in outline dimensions removed

 

1.2

 

06.03.2017

 

changing recommended footprint; addition information in interface

 

1.3

 

10.03.2017

 

changing addition information in interface

 

1.4

 

30.05.2017

 

adding label

 

1.5

 

08.06.2017

 

added IC notice

 

1.6

 

21.12.2017

 

changing recommended footprint

 

1.7

 

25.01.2018

 

remove SMR-324

 

1.8

 

12.02.2018

 

changing handling information

 

1.9

 

20.04.2018

 

adding in mechanical

 

2.0

 

11.06.2018

 

changing order information (system pattern)

 

2.1

 

26.11.2019

 

formal correction to user manual

 

2.2 

03.08.2020 

new layout  

 

InnoSenT GmbH

 

Am Rödertor 30

 

97499 Donnersdorf 
GERMANY

 

Tel.: 

+49 (0)9528 - 9518 - 0

 

E-Mail: info@innosent.de 
URL: 

www.innosent.de

 

P

age 

 

U

se

r M

an

ual

 S

M

R

-314

 / 3

34

 

V

er

si

on 2

.2

 

Summary of Contents for SMT mountable Series

Page 1: ...function of the product CERTIFICATES InnoSenT GmbH has established and applies a quality system for development production and sales of radar sensors for industrial and automotive sensors https www i...

Page 2: ...lance p 25 25 overall gain conversion gain antenna gain SMR 314 GOA SMR 314 24 dB SMR 334 GOA SMR 334 29 Power supply supply voltage VCC 3 2 3 3 3 4 V supply current ICC 47 57 mA Frequency Divider Pre...

Page 3: ...SMR 314 90 90 system pattern 10dB azimuth system_az 121 elevation system_el 111 System Pattern SMR 334 90 90 system pattern 10dB azimuth system_az 43 elevation system_el 116 CONFIDENTIAL AND PROPRIETA...

Page 4: ...ut 3 IF1 output signal I nphase 4 IF2 output signal Q adrature 5 enable input TX output power enable active high 6 GND input analog ground 7 VCC input supply voltage 8 VCC_PTAT input divider ratio set...

Page 5: ...the following For optimum results the reflow oven should have nitrogen purge we recommend 1000ppm To avoid damage during assembly solder re flow attachment follow the guidelines in IPC JEDEC J STD 020...

Page 6: ...Human Body Model HBM Component Level CDM 500V according to JEDEC JESD22 C101 Field Induced Charged Device Model CDM Test Method for Electrostatic Discharge With stand Thresholds of Microelectronic Co...

Page 7: ...uthorization to operate this equipment Manufacturers of mobile or fixed devices incorporating SMR 3X4 modules are authorized to use the FCC Grants and IC Certificates of the SMR 3X4 modules for their...

Page 8: ...Data Sheet are no longer valid VERSION DATE COMMENT 1 0 13 04 2016 initial release 1 1 26 07 2016 data matrix code in outline dimensions removed 1 2 06 03 2017 changing recommended footprint addition...

Reviews: