InnoSenT SMT mountable Series User Manual Download Page 2

  

Experience and Reliability in Radar Technology 

 

disclosed by the recipient to third parties without prior consent of InnoSenT in writing.

 

 

 

 

 

PARAMETERS

 

 
 

PARAMETER

 

CONDITIONS

 

SYMBOL

 

MIN

 

TYP

 

MAX

 

UNITS

 

 

Radar

 

VCO frequency range

 

 

f

VCO

 

24.050

 

 

24.250

 

GHz

 

Tuning voltage

 

to cover VCO frequency range

 

V

tune

 

0.7

 

 

2.5

 

V

 

VCO tuning sensitivity

 

within VCO frequency range

 

K

VCO

 

 

720

 

2000

 

MHz/V

 

output power (EIRP)

 

 

P

out

 

 

 

20

 

dBm

 

IF output DC-Offset

 

 

IF

1/2_DC-offset

 

1.4

 

1.8

 

2.2

 

V

 

IF-Bandwidth (-3dB)

 

 

B

 

0

 

 

1M

 

Hz

 

signal level

 

(RCS = 0.5m² @ 5m)

 

SMR - 314

 

IF

1/2 - SMR-314

 

60

 

 

250

 

µVrms

 

SMR - 334

 

IF

1/2 - SMR-334

 

120

 

 

360

 

µVrms

 

noise level

 

100Hz...1kHz

 

N

1/2

 

 

 

20

 

µVrms

 

quadrat. phase imbalance

 

 

ε

p

 

-25

 

 

25

 

°

 

overall gain

 

(conversion gain + antenna 

gain)

 

SMR - 314

 

G

OA - SMR-314

 

 

24

 

 

dB

 

SMR - 334

 

G

OA - SMR-334

 

 

29

 

 

 

 

Power supply

 

supply voltage

 

 

V

CC

 

3.2

 

3.3

 

3.4

 

V

 

supply current

 

 

I

CC

 

 

47

 

57

 

mA

 

 

Frequency Divider

 

Prescaler division ratio

 

V

CC_PTAT 

= 0 V,

 

D

DIV

 

16

 

 

 

V

CC_PTAT 

= 3.3 V

 

D

DIV

 

8192

 

 

 

Prescaler output voltage

 

Peak to peak voltage 

Terminated with 
50Ω D

DIV

=8192

 

 

V

DIV

 

 

60

 

 

120

 

 

260

 

 

mV

 

Prescaler supply voltage

 

 

V

CC_DIV

 

3.2

 

3.3

 

3.4

 

V

 

Prescaler supply current

 

 

I

CC_DIV

 

 

19

 

 

mA

 

 

Environment

 

operating temperature

 

 

T

OP

 

-40

 

 

+85

 

°C

 

storage temperature

 

 

T

STG

 

-40

 

 

+85

 

°C

 

 

Mechanical Outlines

 

 

outline dimensions

 

 

compare to schematic on page 4

 

height 

length 

width

 

3.1

 

21.4

 

15.0

 

 

mm

 

 
 

 
 

 

CONFIDENTIAL AND PROPRIETARY

 

The information contained in this document shall remain the sole and exclusive property of InnoSenT GmbH and shall not be

 

P

age 

 

U

se

r M

an

ual

 S

M

R

-314

 / 3

34

 

V

er

si

on 2

.2

 

Summary of Contents for SMT mountable Series

Page 1: ...function of the product CERTIFICATES InnoSenT GmbH has established and applies a quality system for development production and sales of radar sensors for industrial and automotive sensors https www i...

Page 2: ...lance p 25 25 overall gain conversion gain antenna gain SMR 314 GOA SMR 314 24 dB SMR 334 GOA SMR 334 29 Power supply supply voltage VCC 3 2 3 3 3 4 V supply current ICC 47 57 mA Frequency Divider Pre...

Page 3: ...SMR 314 90 90 system pattern 10dB azimuth system_az 121 elevation system_el 111 System Pattern SMR 334 90 90 system pattern 10dB azimuth system_az 43 elevation system_el 116 CONFIDENTIAL AND PROPRIETA...

Page 4: ...ut 3 IF1 output signal I nphase 4 IF2 output signal Q adrature 5 enable input TX output power enable active high 6 GND input analog ground 7 VCC input supply voltage 8 VCC_PTAT input divider ratio set...

Page 5: ...the following For optimum results the reflow oven should have nitrogen purge we recommend 1000ppm To avoid damage during assembly solder re flow attachment follow the guidelines in IPC JEDEC J STD 020...

Page 6: ...Human Body Model HBM Component Level CDM 500V according to JEDEC JESD22 C101 Field Induced Charged Device Model CDM Test Method for Electrostatic Discharge With stand Thresholds of Microelectronic Co...

Page 7: ...uthorization to operate this equipment Manufacturers of mobile or fixed devices incorporating SMR 3X4 modules are authorized to use the FCC Grants and IC Certificates of the SMR 3X4 modules for their...

Page 8: ...Data Sheet are no longer valid VERSION DATE COMMENT 1 0 13 04 2016 initial release 1 1 26 07 2016 data matrix code in outline dimensions removed 1 2 06 03 2017 changing recommended footprint addition...

Reviews: