background image

iSYS-4001

quick-start  guide V1.1

www.InnoSenT.de

30°

45°

60°

2.2m

Summary of Contents for iSYS-4001

Page 1: ...iSYS 4001 quick start guide V1 1 www InnoSenT de 30 45 60 2 2m...

Page 2: ...tion settings short range configuration detection fields long range configuration typicall detection patter for cars individual configuration iSYS 4001 detection fields depending on mounting height de...

Page 3: ...liability in Radar Technology www InnoSenT de iSYS 4001 quick start guide The quick start guide gives you a guidence to set up the iSYS 4001 quickly in your application A more detailed instruction is...

Page 4: ...se one of the available configuration files to set up the sensor The DEFAULT setting of the sensor when powered up for the first time is the Short Range configuration The following configuration files...

Page 5: ...active high if object exist active low if NO object exist approaching active high if object exist active low if NO object exist approaching active high if object exist active low if NO object exist ou...

Page 6: ...n the following mounting height 2 2m mounting angle 30 45 60 depending on your application In the short Range configuratoin the ambiguity range is set to 50m Typical detection fields for a person are...

Page 7: ...configuration detection fields The schematic below shows typical detection areas for the iSYS 4001 for persons The detection areas are based on real measurements but can differ for objects with diffe...

Page 8: ...gle 90 In the Long Range configuratoin the ambiguity range is set to 150m This configuration is supposed to use in applications like traffic monitoring collision avoidance systems The typical detectio...

Page 9: ...50m h 2 2m 5m 10m 15m 20m 25m 50m h 2 2m long range configuration typical detection distances for cars To get an impression about the typical detection range of the iSYS 4001 real measurements were p...

Page 10: ...S 4001 GUI and connect to sensor adjust Threshold in that way that the FFT peaks are above the threshold function only available if Live View is stoped select the Line Filter option if there are fixed...

Page 11: ...tting 1 lowest adjust filter as long as the wanted result appears signal has continous and constant amplitude YES NO open Tab Raw Signals and start Live View open window Amplification Settings open wi...

Page 12: ...ansmission or reception is possible On the right side you see some examples of different detection fields depending on the mounting height and based on the 3dB antenna parameters of the iSYS 4001 The...

Page 13: ...depending on mounting height examples The coverage area of the iSYS 4001 is depending on the distance to the object as well as to the mounting situation 0m 5m 10m 15m 0m 1 3m 1 4m 3 4m 3 2m 6 4m 6 8m...

Page 14: ...y detection fields depending on mounting angle examples The coverage area of the iSYS 4001 is also depending on the mounting angle of the sensor 0m 5m 10m 15m 0m 2 6m 2 1m 3 4m 3 2m 4 6m 8 5m 5m 10m 0...

Page 15: ...y density in the right area of the antenna beams decreases if the mounting angle of the module rises Therefore the detection field gets broader but because of the lower energy the same object has to m...

Page 16: ...adar Although RCS is technically an area and typically expressed in square meters m2 The RCS of an object is depending on its geometric cross section the geometric cross section refers to the area the...

Page 17: ...the typical detection ranges of the iSYS 4001 for different objects The maximum detection range is limited to 150m 20m 0m 40m 60m 80m 100m 120m 140m 160m 20m 0m 40m 60m 80m 100m 120m 140m 160m 20m 0m...

Page 18: ...Select the proper distance range depending on your application The ambiguity range is the distance within the object will be calculated correctly If an object is detected outside of the selected ambi...

Page 19: ...calculation distance of the object at 10m 60m ambiguity range of 50m 10m 30m 40m 50m 60m 70m 10m 0m 20m 30m 40m 50m 60m 70m 80m 80m 80m object is detected within the ambiguity range of 50m distance c...

Page 20: ...moving objects The FSK modulation is the standard mode of the iSYS 4001 Within this mode different speed and distance limits can be set IMPORTANT with the FSK modulation there is no possibility to det...

Page 21: ...nnoSenT de FSK modulation The distance to more than one object can only than be determined if the speed of the two objects is different If not a distance that is between the detected objects will give...

Page 22: ...n the left side If a bandwidth of 50MHz is used two objects can be detected as soon as they are not closer together than 3m If the objects get closer to each other they appear as one object In this ca...

Page 23: ...cal view differs from the radar view 3m 3m 1 5m 1 5m 0 6m 0 6m radar view optical view optical view Bandwidth 50MHz two objects with the same RCS are closer than 3m they appear as one target Bandwidth...

Page 24: ...and Reliability in Radar Technology more details This quick start guide gives you only a short overview over the physical characteristics of radar If you want to know more we recommend to have a look...

Page 25: ...enT de 18 19 part numbers contact information If you have any questions please contact us Corinna Mergenthal Tel 49 9528 9518 84 E Mail corinna mergenthal innosent de Martin Maidhof Tel 49 9528 9518 1...

Page 26: ...Contact Details Tel 49 9528 9518 0 E Mail info innosent de www innosent de...

Reviews: