iSYS-4001 |
quick-start guide
www.InnoSenT.de
11
Experience and Reliability in Radar-Technology -
www.InnoSenT.de
activate automatic gain
control and adjust the
control rate via offset setting
(1 = lowest)
adjust filter as long as the
wanted result appears
signal has continous
and constant amplitude
YES
NO
open Tab“Raw Signals“
and start „Live View“
open window
„Amplification Settings“
open window
„Output 1“
select „Output Type“ and „PIN
configuration“ and adjust
switch-on and switch-off
delay
open window
„Correction“
adjust „Velocity Correction“
corresponding to sensor
installation