All installation must be carried out by a competent person or qualified electrician. Before connecting the mains supply
ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
This appliance must be connected directly to the mains using an omnipolar circuit breaker with a minimum opening of 3mm
between contacts.
The installer must ensure that the correct electrical connection has been made and that it complies with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the the mains connection and power cord for damage. If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified persons in order to avoid a safety hazard.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue
= N or Neutral
Green and Yellow = E or Earth
220-240V~
N
L
L
N
N
L
L
Brow
n
Blue
(
Blue
)
(Brown)
(Green/Yellow)
This appliance requires a 40 Amp Miniature Circuit Breaker.
To avoid the risks that are always present when you use an electrical appliance it is important that this appliance is installed
correctly and that you read the safety instructions carefully to avoid misuse and hazards. Please keep this instruction booklet
for future reference and pass it on to any future owners. After unpacking the appliance please check that it is not damaged. If
in doubt, do not use the appliance but contact Customer Services shown in the Care & maintenance section below.
Electrical Installation
WARNING: This is a Class I appliance and MUST be earthed.
37