15
2002 - INLINE, INC.
MSV0804 OPERATION MANUAL - v1.0 4/26/02
Set-up Commands
These commands are for configuring the switcher, and you only need to send them once. If using a third
party control system, you should place most commands in this section in the start-up section of the
program.
COMMAND
DESCRIPTION
[ARC]
Request for model and version information.
[CPx@]
Re-sets the communications port to default of 9600, 8, N and 1.
•
Where x = 1
[CPx?]
Query communications port for current settings.
•
Where x = 1
[CPxbpsfd]
Configures the communications port for baud rate, parity, stop bits, flow control
and duplex.
•
Where
o
x = 1
o
b = 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600, 4 for 19200, 5
for 38400
o
p = 0 for no parity, 1 for odd parity, 2 for even parity
o
s = 0 for 1 stop bit, 1 for 2 stop bits
o
f = 0 to disable flow control, 1 to enable flow control
o
d = 0 for full duplex and 1 for half duplex
[DFLTx]
Performs a factory reset. The partial reset will default I/O configurations, volume
levels and serial set-up but does not reset presets. A full reset will reset all
parameters including presets.
•
Where x = 0 for partial reset, 1 for full reset
[FPx]
Enable/disable front panel control and request current status.
•
Where
o
x = 0 to disable, 1 to enable
o
x = ? to request current state
o
x = (left blank) to toggle current state
[RESx]
Enable/disable serial responses from switcher.
•
Where x = 0 to disable, 1 to enable
Level Commands
There are three predefined switching levels. Levels consist of combinations of Video (RGB), Sync (HV)
and Audio boards (A). For commands that use level designators see Switching Commands below.
Default levels include:
•
Level 1 - RGBHVA
•
Level 2 - RGBHV
•
Level 3 - Audio only