Inline IN2013 Operation Manual Download Page 13

12

IN2013 OPERATION MANUAL  -  REV 1.1  12/11/99                                            

©1995  -  INLINE, INC.

SW2 - Monitor Emulation Switches                            Factory Default Settings:  0000000000
These dip switches are normally exposed.  Setting a switch to ON (1) grounds a specific pin on
the input connector for purposes of monitor emulation.  Setting a switch to OFF (1) passes the
pin through the IN2013.  If you don’t know what to do, set all dip switches to 0.  See pages 7 & 8
for detailed instructions.

Switch Number

Function When Set to ON (1)

1

Ground Pin 9

2

Ground Pin 2

3

Ground Pin 3

4

Ground Pin 4

5

Ground Pin 5

6

Ground Pin 6

7

Ground Pin 7

8

Ground Pin 8

9

Ground Pin 1

10

N/C

SW3 - Input Computer Select                            

Factory Default Settings:  1111111000

Switches 8, 9 & 10 on SW3 determine where the interface looks for sync on the input connector
and what types of input sync it can accept.  The factory default setting works with most Sun and
SGI workstations.  These dip switches are exposed through a window in the bottom case of the
interface.  For a detailed setting chart see page 4.

Important Note:  #1 - #7 are normally covered because they must be left in the ON position.  If
any of these switches is set to OFF the interface will not pass through any sync.

Dip 8/9/10

Input Sync Format / Location

Computers

000

RGBS - Composite Sync on pin 5

Sun SPARC

(this mode also works with RGsB signals)

101

RGBHV - H. Sync on pin 6 / V. Sync on pin 2

Sun SPARC

001

RGsB only - ignores all other sync signals

NeXT / SGI

011

RGBS - Composite Sync on pin 3

SGI

100

RGBHV - H. Sync on pin 4 / V. Sync on pin 5

SGI

010

RGBHV - H. Sync on pin 5 / V. Sync on pin 9

IBM PowerPC

Summary of Contents for IN2013

Page 1: ...OPERATION MANUAL DEDICATED VIDEO INTERFACE SERIES IN2013 High Resolution Video Interface for 13W3 Workstations...

Page 2: ...7 Internal Controls For Technicians Only 8 12 Opening the IN2013 Case 8 Diagram 2 Internal View 9 Blue and Red Gain Controls 9 Diagram 3 Dip Switches 10 Internal Dip Switches 11 12 SW1 Output Sync Ho...

Page 3: ...t other workstation signals by flipping one or two dip switches Exceptional Video Performance Featuring advanced video amplification circuitry the IN2013 offers video bandwidth in excess of 230 MHz en...

Page 4: ...tation for both the workstation graphics card and the data display device to ensure compatibility Installation steps are listed below and outlined in Diagram 1 on page 5 1 Turn the computer and comput...

Page 5: ...ches see page 7 6 Connect the IN2013 output to the display device RGB input Using high quality video cables connect the output BNCs on the IN2013 to the RGB input on your large screen monitor or data...

Page 6: ...5 RGBHV Cable Power Supply 15V 900mA RGB Input DIAGRAM 1 IN2013 INSTALLATION INPUT HORIZONTAL POSITION LOCAL MONITOR OUTPUT 2013 HIGH RESOLUTION VIDEO INTERFACE FOR 13W3 WORKSTATIONS VERTICAL SYNC HO...

Page 7: ...horizontal position control until the image is centered as desired 3 If the image appears dark or the colors are not properly displayed fine tune the controls on both the display device and the IN2013...

Page 8: ...local monitor If you are not using a local monitor but need to emulate a specific mode locate your workstation type and desired mode in the chart below If you are not sure of the exact mode to select...

Page 9: ...ircuit board PCB to the lower case To assist in reassembly make note of the red ground strap terminal on the center screw 6 Lift the PCB Input Output connector assembly away from the lower case Flip t...

Page 10: ...ale reproduction and color accuracy therefore these controls should only be adjusted by qualified technicians having the necessary test equipment Since the gain pots must be adjusted with power applie...

Page 11: ...10 IN2013 OPERATION MANUAL REV 1 1 12 11 99 1995 INLINE INC...

Page 12: ...another small tool SW1 Output Sync Horizontal Position Control Factory Default Settings 0100001010 These dip switches are normally all covered except for 6 Switch Number Function When Set to ON 1 1 N...

Page 13: ...Switches 8 9 10 on SW3 determine where the interface looks for sync on the input connector and what types of input sync it can accept The factory default setting works with most Sun and SGI workstati...

Page 14: ...ndwidth 230 MHz 3dB 7 volt input signal GENERAL Controls Horizontal Position Video Gain Sharpness Input Computer Select Monitor Emulation Power Supply US IN9207 1 15VDC 900mA UK European IN9208 15VDC...

Page 15: ...d warranty or merchantibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate Howev...