Inline IN2013 Operation Manual Download Page 12

11

©1995  -  INLINE, INC.                                              

 IN2013 OPERATION MANUAL  -  REV 1.1  12/11/99

INTERNAL DIP SWITCHES

In order to simplify operation, the IN2013 was designed so that dip switches needed by most
users are exposed through windows in the case metal while reserved switches and other dip
switches for highly specialized functions are covered.  This helps prevent operational problems
which might occur if the dip switches were set to unusual settings but also provides the
flexibility so that advanced technicians may fully customize the interface settings if necessary.
The IN2013 will function properly for the vast majority of installations using the factory default
dip switch settings for all hidden dip switches.

Hidden dip switches must only be adjusted by qualified technicians as this requires the
interface to be opened and disassembled, raising the possibility of physical damage or static
discharge damage to sensitive internal components (not covered under warranty).

The IN2013 has three banks of dip switches as described below and shown in Diagram 3 on the
preceding page.  Dip switches are made of thin, soft plastic and should be gently adjusted using
the Inline alignment tool provided or using another small tool.

SW1 - Output Sync  / Horizontal Position Control       Factory Default Settings:
0100001010
These dip switches are normally all covered except for #6.

Switch Number

Function When Set to ON (1)

1

N/C

2

Green Out (set opposite of Switch #3)

3

Monochrome Out (set opposite of Switch #2)

4

Manual Output Sync - RGBS (only works when #7 is set to OFF)

5

Manual Output Sync - RGsB (only works when #7 is set to OFF)

6

Horizontal Position Control Disable

7

Automatic Output Sync (Set to OFF for Manual Output Sync Select)

8

N/C

9

Reserved

10

N/C

Select RGB Output or Composite Monochrome Output

RGB Output (factory default)    

#2 ON, #3 OFF

Composite Monochrome Outputon the Green Connector

#2 OFF, #3 ON

(RGB summed together along with Sync)

Setting Output Sync Format
The IN2013 with factory default settings automatically sets the output sync according to the
number of cables connected to the output BNCs.  A green LED located next to three of the
output BNCs indicates that sync is present and also indicates the current sync format.  If desired,
you may manually force the interface into a specific output mode.   Please note that all 3 output
LED indicators turn on when the interface is set to manual output sync mode.

Automatic Output Sync Selection (factory default)

#7 ON

Manual Output Sync Selection

#7 OFF

Select RGBHV Output Sync

#4 OFF, #5 OFF

Select RGBS Output Sync

#4 ON, #5 OFF

Select RGsB Output Sync

#4 OFF, #5 ON

Summary of Contents for IN2013

Page 1: ...OPERATION MANUAL DEDICATED VIDEO INTERFACE SERIES IN2013 High Resolution Video Interface for 13W3 Workstations...

Page 2: ...7 Internal Controls For Technicians Only 8 12 Opening the IN2013 Case 8 Diagram 2 Internal View 9 Blue and Red Gain Controls 9 Diagram 3 Dip Switches 10 Internal Dip Switches 11 12 SW1 Output Sync Ho...

Page 3: ...t other workstation signals by flipping one or two dip switches Exceptional Video Performance Featuring advanced video amplification circuitry the IN2013 offers video bandwidth in excess of 230 MHz en...

Page 4: ...tation for both the workstation graphics card and the data display device to ensure compatibility Installation steps are listed below and outlined in Diagram 1 on page 5 1 Turn the computer and comput...

Page 5: ...ches see page 7 6 Connect the IN2013 output to the display device RGB input Using high quality video cables connect the output BNCs on the IN2013 to the RGB input on your large screen monitor or data...

Page 6: ...5 RGBHV Cable Power Supply 15V 900mA RGB Input DIAGRAM 1 IN2013 INSTALLATION INPUT HORIZONTAL POSITION LOCAL MONITOR OUTPUT 2013 HIGH RESOLUTION VIDEO INTERFACE FOR 13W3 WORKSTATIONS VERTICAL SYNC HO...

Page 7: ...horizontal position control until the image is centered as desired 3 If the image appears dark or the colors are not properly displayed fine tune the controls on both the display device and the IN2013...

Page 8: ...local monitor If you are not using a local monitor but need to emulate a specific mode locate your workstation type and desired mode in the chart below If you are not sure of the exact mode to select...

Page 9: ...ircuit board PCB to the lower case To assist in reassembly make note of the red ground strap terminal on the center screw 6 Lift the PCB Input Output connector assembly away from the lower case Flip t...

Page 10: ...ale reproduction and color accuracy therefore these controls should only be adjusted by qualified technicians having the necessary test equipment Since the gain pots must be adjusted with power applie...

Page 11: ...10 IN2013 OPERATION MANUAL REV 1 1 12 11 99 1995 INLINE INC...

Page 12: ...another small tool SW1 Output Sync Horizontal Position Control Factory Default Settings 0100001010 These dip switches are normally all covered except for 6 Switch Number Function When Set to ON 1 1 N...

Page 13: ...Switches 8 9 10 on SW3 determine where the interface looks for sync on the input connector and what types of input sync it can accept The factory default setting works with most Sun and SGI workstati...

Page 14: ...ndwidth 230 MHz 3dB 7 volt input signal GENERAL Controls Horizontal Position Video Gain Sharpness Input Computer Select Monitor Emulation Power Supply US IN9207 1 15VDC 900mA UK European IN9208 15VDC...

Page 15: ...d warranty or merchantibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate Howev...

Reviews: