When measured temperature ≤ the setting value of low
temperature AL, it will alarm. The screen will rotate to
display“AL”and current temperature, buzzer will“bi-bi-Biii”,
until the temperature > AL, buzzer will be off and return to
normal display and control. Or press any button to only
turn the buzzer alarm off.
High and low temperature alarm will be pushed to mobile
APP and remind the customer that the product is in alarm
state.
6.6 Continuous Heating Time Alarm(CT)
When measured temperature ≤ the starting heating
temperature, the output control is turned on. If the
continuous heating time arrives, but the measured
temperature has not risen to the stop heating temperature,
at this time the heater is abnormal or the probe is
abnormal, and the output is forcibly turned off. PV will
show E5, the buzzer keeps ringing, and the alarm status
is pushed to the mobile APP to remind the customer that
the product is in an alarm state and need to check in time.
6.7 Temperature Calibration(CA)
When the measured temperature deviates from the
standard temperature, the temperature calibration function
can be used to calibrate the measured value consistent
with the standard value. The calibrated temperature = the
measured temperature value + the calibration value.
6.8 Fahrenheit or Celsius Setting(CF)
Support setting Fahrenheit or Celsius. The default
11