2. Installation of Flex5/R
2. Installation of Flex5/R
The Flex5/R device is DIN-Rail mount compatible.
It must be installed inside a fireproof enclosure with UL 94-5V flamability rating.
2.1 Anti-tamper
A
B
D
C
The peripherals with visible terminals and which do not have an anti-tamper device can still be equipped
with protection by intervening on the assembly procedure.
Please note that in order to comply with security standards, all the control panel peripherals must be pro-
tected against tamper.
Here we provide information on one of the possible procedures that can be adopted. This involves the
assembly of a microswitch on the device, which signals any attempted tamper, and the consequent pro-
gramming of the terminal used for this contact.
1.
Procure a microswitch with at least two normally-open contacts
[A]
(preferably with 3 contacts: COM-
NO-NC).
2.
Employ a terminal and program it as a ‘24H’ input, whose description type is ‘Tamper’, balanced with
a single 6K8Ω
[B]
resistance, unlimited alarm cycles and belonging to a partition that is viewable on
at least one keypad.
3.
Using 2 wires, connect the microswitch to the ‘24H’ input terminal.
6
Installation and programming manual- 101