Flex5/R

5 relay outputs expansion module

Installation and programming manual

 

EN 50131-1

EN 50131-3

EN 50130-4

EN 50130-5

CEB T031

Summary of Contents for Flex5/R

Page 1: ...Flex5 R 5 relay outputs expansion module Installation and programming manual EN 50131 1 EN 50131 3 EN 50130 4 EN 50130 5 CEB T031 ...

Page 2: ... Addressing of Flex5 R 11 2 4 2 Addressing from Flex5 R 11 2 4 3 Enrolling of Flex5 R 13 3 Programming of Flex5 R 15 3 1 Programming the expansion boards 15 3 1 1 Expansion parameters 15 4 General information 16 4 1 About this manual 16 4 2 Manufacturer s details 16 4 3 Simplified EU Declaration of Conformity 16 4 4 Warranty 16 4 5 Limited warranty 17 4 6 Documents for the users 17 4 7 Disposal of...

Page 3: ...ontrol panel as a relay output dry contact for DC and AC devices up to a maximum of 10A Relay output In the case of relay use outputs with DC currents it is advisable to consult the following diagrams for the cor rect sizing of the system loads based on the supplied current Electrical endurance Cycles Switching DC current A Maximum DC load breaking capacity DC voltage V Switching DC current A ...

Page 4: ...ED during the automatic enrolling phase via the control panel will blink rapidly LEDs L1 L5 during normal functioning of the device indicate the status of the outputs l LED on relay active l LED off relay inactive During the manual addressing process LEDs P and L1 L5 indicate the address of the peripheral in accordance with the table provided in the device project paragraph 4 Installation and prog...

Page 5: ... 30W 120V Electronic transformers 4A Motors cosφ min 0 6 3 5A Range of the voltage connectible to the OUTx output Alternating Current from 0 to 253V 50 60Hz continuous current from 0 to 253V 0 35A from 0 to 28V 10A Operating environmental conditions Temperature from 10 to 40 C Relative humidity 75 without condensation Security rating 2 Environmental class II DIN rail mount 5 module enclosure Dimen...

Page 6: ...ainst tamper Here we provide information on one of the possible procedures that can be adopted This involves the assembly of a microswitch on the device which signals any attempted tamper and the consequent pro gramming of the terminal used for this contact 1 Procure a microswitch with at least two normally open contacts A preferably with 3 contacts COM NO NC 2 Employ a terminal and program it as ...

Page 7: ...ns the switch lever is compressed If a tamper attempt occurs the lever will release thus generating the opening of the contact and an immediate alarm on the 24H terminal Note This wiring method can be applied in most situations however it is only a point of reference In order to ensure proper protection you must always take in to account the specific mechanical and electrical conditions of the dev...

Page 8: ...aker trip switch must be located externally to the apparatus and should be easily accessible The distance between contacts must be at least 3mm The manufacturer strongly advises the use of a magnetothermic switch with C intervention curve and maximum nominal current 16A The electrical earthing system of the site must be compliant with all safety standards and laws in force Be careful during the ma...

Page 9: ...rminals D S on the motherboard Sizing The sizing of the I BUS line i e the distribution of peripherals and the use of cables to connect them must be done on the basis of various project factors in order to ensure the diffusion of the signals of conductors D and S and the power supplied by conductors and The factors are l The current consumption of the connected devices In the case of insufficient ...

Page 10: ...one from another in order for them to be placed in the con figuration This is possible firstly by assigning an address to each peripheral The addressing procedure changes in accordance with the type of peripheral The types available are l keypads both with keys and LCD display and also with touch screens l proximity readers both stand alone and integrated into keypads l expansions both with input ...

Page 11: ... as described above it is possible to assign an address manually This method requires the use of the ENROLL button and LEDs L1 L5 and P A maximum of 100 addresses can be set in this way The procedure to be followed is as follows 1 Press and hold the ENROLL button for 3 seconds 2 After 3 seconds the device accesses address programming mode The current address is indicated on the red LEDs in binary ...

Page 12: ...75 0 0 L L 0 0 26 0 1 1 0 1 0 76 0 0 L L 0 L 27 0 1 1 0 1 1 77 0 0 L L L 0 28 0 1 1 1 0 0 78 0 0 L L L L 29 0 1 1 1 0 1 79 0 L 0 0 0 0 30 0 1 1 1 1 0 80 0 L 0 0 0 L 31 0 1 1 1 1 1 81 0 L 0 0 L 0 32 1 0 0 0 0 0 82 0 L 0 0 L L 33 1 0 0 0 0 1 83 0 L 0 L 0 0 34 1 0 0 0 1 0 84 0 L 0 L 0 L 35 1 0 0 0 1 1 85 0 L 0 L L 0 36 1 0 0 1 0 0 86 0 L 0 L L L 37 1 0 0 1 0 1 87 0 L L 0 0 0 38 1 0 0 1 1 0 88 0 L L 0...

Page 13: ...hen in the section on the right click on the Add device on BUS button A window opens where you can select the devices to be configured and add them to the configuration In the section on the left you can increase the number using the button corresponding to the selected device type To remove a device from the structure work through the Add device procedure but instead deselect the device you want ...

Page 14: ... is possible by enabling the menu options after reaching the instal ler menu section Type in Code Installer PROGRAMMING Expansions Enable Disable In this section it is possible to add remove readers from the configuration by means of keys and 14 Installation and programming manual 101 ...

Page 15: ...n the button Via keypad Type in Code Installer PROGRAMMING Expansions ChoosePeripheral This section allows the programming of the various options of the selected expansion 3 1 1 Expansion parameters Parameter Software section Installer menu sec tion Description Description string of the expansion to be customized by the installer Configured expan sions selected expansion Expansions Choo sePeripher...

Page 16: ...oduct shall be free from defects in materials and workmanship under normal use for a period of 24 months As Inim Electronics does not install this product directly and due to the possibility that it may be used with other equipment not approved by Us Inim Electronics does not warrant against loss of quality degradation of performance of this product or actual damage that results from the use of pr...

Page 17: ...the reser ved area after the login and then to the section of each product 4 7 Disposal of the product Informative notice regarding the disposal of electrical and electronic equipment applicable in countries with differentiated waste collection systems The crossed out bin symbol on the equipment or on its packaging indicates that the product must be disposed of correctly at the end of its working ...

Page 18: ...4 General information 18 Installation and programming manual 101 ...

Page 19: ...Flex5 R 2021 Inim Electronics S r l 19 4 7 Disposal of the product ...

Page 20: ...info inim biz _ www inim biz Via dei Lavoratori 10 Loc Centobuchi 63076 Monteprandone AP I Inim Electronics S r l TALY Tel 39 0735 705007 _ Fax 39 0735 704912 DCMIINE0FLEX5R 101 20210526 ...