39
Programming the SmartLink-GP
Programming manual
Note:
The code which allows the central station to identify the
system must be entered in the Codes window (refer to
paragraph 3.5.4 Setting up Caller ID codes).
Setting Contact ID at default
Select
Default Contact ID
bottom left: SmartLink-GP will apply Contact ID
default configuration to all events.
The event default codes are DCS (Digital Communication Standard)
international reporting protocol, for example:
Indicates
• 3=trouble
• A2=Low Battery
• 1=New event
Note:
You can create “model” solutions tailored to the needs of
specific central stations, for each solution you can:
1. select default Contact ID reporting protocol
2. customize the Codes to central station requirements
3. print the Contact ID table using
File, Print
.
Using the SmartLink-GP as an intrusion control panel
The event associated with status change on input 5 (arm/disarm intrusion
panel) does not have a Contact ID code.
The events associated with status change on the inputs will have Contact ID
codes which depend on the logic status of the input and its balance:
Event
Protocol
class
Event code
Qualifier
Low
battery
3
A2
1
Input logic status
Intrusion control
Protocol
class
Event
code
Qualifier
Alarm
1
3A
1
Standby
1
3A
3
Tamper
1
44
1
Short-circuit
1
44
1