background image

1

Installation and programming manual

Air2-OTT100W

Triple technology wireless detector
for outdoor use

Installation and programming manual

Summary of Contents for Air2-OTT100W

Page 1: ...1 Installation and programming manual Air2 OTT100W Triple technology wireless detector for outdoor use Installation and programming manual ...

Page 2: ...s 6 2 3 Test function 7 2 4 Inhibition function 7 3 Installation 7 3 1 Placement 7 3 2 Installation procedure 8 4 Programming 8 5 Maintenance and periodic checks 9 6 Disposal and scrapping 9 Appendix Declaration of conformity 10 Copyright The information contained in this document is the sole property of INIM Electronics s r l No part may be copied without written authorization from INIM Electroni...

Page 3: ...w consumption power supply range 3 to 9V Test function to signalling each alarm by LED blinking auto power off after 4 minutes Tamper and dislodgement system Inhibition LED and transmitting function for battery life saving always on Two PIRs and one microwave MW programmable sensors AND OR selectable function Mechanism for horizontal coverage adjustment Precision adjustment of lower beam patented ...

Page 4: ... L and U brackets fixing L External screw for L and U brackets fixing M Base enclosure screw Table 3 Electronic part description N Terminal board for wire connection O Red LED for radio transmission P Yellow LED for MW Q Left green LED for each higher PIR detection R Right green LED for each lower PIR detection S Jumper T Microwave sensitivity adjustment trimmer U Higher infrared sensor PIR 1 V Lo...

Page 5: ...arately U shaped brackets L shaped brackets 2 FUNCTIONING 2 1 Detection range ADJUSTMENT Use the trimmer MW table 3 T to adjust the microwave sensitivity the sensitivity is increased turning it clockwise By using the knob table 2 F it is possible to move the PIR2 lower in order to obtain different ranges from 3m to 12m Table 4 Technical specifications of Air2 system Operating frequency range 868 0...

Page 6: ...evant working examples Table 6 Side view PIR2 position Distance A 3 m B 4 m C 7 m D 10 m E 12 m 1 2m 3m 4m 7m 10m 12m E A Table 7 Working examples A Detector B Protected area limit C The pet is detected only by two of the three sensors lower PIR and MW No alarm D The person is detected by all three sensors upper PIR lower PIR MW Alarm E The person is detected by two sensors upper PIR and MW No ala...

Page 7: ...e LEDs deactivated the function inhibition is automatically activated in order to safe battery life This implies that if the detector has been installed in a populated area the detector will no switch the alarm relay if the detection area is free for three minutes at least This function avoid that the detector triggers the alarm relay continuously In order to verify if the detector is working prop...

Page 8: ...nto the holes 7 Screw up the case with the screws Pay attention to not damage anti tam per switch support knock out Note Use the lower hole to fix the hermetic casing on the wall 8 Enroll the detector refer to Air2 BS200 transceiver installation manual 9 Insert the o ring gasket table 2 I into its seat located on the electronic holder table 2 D Note Pay attention to not stretch out the o ring gask...

Page 9: ...ove it 2 Disconnect the detector disconnect all the terminals on the terminal block 3 Divide the parts by type and dispose of them in accordance with applicable laws ATTENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 9 Sensor programming DIP 3 OFF ON DIP 4 OFF Triple...

Page 10: ...INIM Electronics s r l dichiara che questo Air2 OTT100W è con forme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Lietuviž Šiuo INIM Electronics s r l deklaruoja kad šis Air2 OTT100W atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas English Hereby INIM Electronics s r l declares that this Air2 OTT100W is in compliance with th...

Page 11: ...11 Installation and programming manual Notes ...

Page 12: ...via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 DCMIINIEA2OTT100W 120 20171222 ...