background image

Table of contents

1.  Air2 system description

3

2.  Air2-FD100 description

4

2.1  Description of parts

5

2.2  Air2-FD100 technical specifications

5

2.3  LED signallings from Air2-FD100

6

3.  Installation of Air2-FD100

7

3.1  Enrolling a wireless device

7

3.2  Battery replacement

8

4.  Programming wireless terminal

9

4.1  Wireless terminal parameters

9

4.2  Real-time

9

5.  General information

10

5.1  About this manual

10

5.2  Manufacturer's details

10

5.3  Notes from the Manufacturer

10

5.4  Simplified EU Declaration of Conformity

10

5.5  Documents for the users

11

5.6  WEEE

11

2

Installation and programming manual- 100-DRAFT

Summary of Contents for Air2-FD100

Page 1: ... JS 8JSFMFTT TNPLF EFUFDUPS E EN 50131 1 EN 50131 5 3 EN 50130 4 EN 50130 5 INCERT CEB T031 OTUBMMBUJPO BOE QSPHSBNNJOH NBOVBM ...

Page 2: ...FD100 7 3 1 Enrolling a wireless device 7 3 2 Battery replacement 8 4 Programming wireless terminal 9 4 1 Wireless terminal parameters 9 4 2 Real time 9 5 General information 10 5 1 About this manual 10 5 2 Manufacturer s details 10 5 3 Notes from the Manufacturer 10 5 4 Simplified EU Declaration of Conformity 10 5 5 Documents for the users 11 5 6 WEEE 11 2 Installation and programming manual 100 ...

Page 3: ...white or brown Air2 FD100 smoke detector Air2 Aria W keypad with graphic display Air2 Hedera outdoor sounder in white or chrome effect Air2 Smarty W indoor sounderflasher Air2 DT200T dual technology curtain detector in white or brown Air2 XIR200W PIR detector 12 m Air2 XDT200W dual technology curtain detector Air2 UT100 universal transceiver Air2 ODI100W outdoor wireless dual infrared detector Air...

Page 4: ...ow to the sampling chamber UUFOUJPO Air2 FD100 is a smoke detector that can be used exclusively for the detection of smoke in the protected area With the use of Air2 FD100 the intrusion control system INIM cannot be considered a fire detection system The operating parameters of detectors can be changed and adapted to the environmental conditions either from the control panel orvia the programming ...

Page 5: ...arts LJ Detector LJ LED red yellow green LJ Battery LJ Tampermicroswitch LJ ENROLL microswitch LJ Base LJ Mounting screw hole 2 2 Air2 FD100 technical specifications Battery type Lithium CR17450 3V estimated life 3 years Low battery fault voltage Less than 2 4V Current draw during standby 70µA ...

Page 6: ...e included 114mm Weight base and battery included 182 g 2 3 LED signallings from Air2 FD100 The tricolourLED 360 visibility indicates the detectorstatus Green one flash every 15 seconds detector operating properly Green one flash every 40 seconds low battery Yellow On solid fault present Yellow flashing sampling chamber contaminated with dust etc Red On solid detector in alarm status 6 Installatio...

Page 7: ...tector to the base turn it still further until notch A aligns with notch C in order to allow the base to close the tamper microswitch 7 Enroll the device 3 1 Enrolling a wireless device The enrolling procedure allows you to associate a wireless device INIM with the transceiver Air2 BS200 which acts in conjunction with the intrusion control panel This procedure varies depending on the control panel...

Page 8: ...ceiver 3 Set the device as Wireless 4 Start the learning phase from the control panel 5 Press the ENROLL button on the wireless device 3 2 Battery replacement When changing the battery it is advisable to press the ENROLL button in order to be sure that the device is synchronized with the wireless transceiver 8 Installation and programming manual 100 DRAFT ...

Page 9: ...the activation command Alarm pulses This is the number of pulses each lasting as long as the programmed Alarm pulse duration necessary to generate a zone alarm event If this value is more than 1 you must also program the Multi pulse time parameter Multi pulse time This parameter applies only when the Alarm pulse num is higher than 1 This is the window during which a number of alarm pulses must be ...

Page 10: ... or replace the parts of this system have authorization to work only on devices marketed underthe brand Inim Electronics 5 3 Notes from the Manufacturer The devices Air2 are certified by IMQ Sistemi di sicurezza Italian certification body The information relating to the power supply batteries required by the devices Air2 are provided in the fol lowing Technical Specification table The manufacturer...

Page 11: ...g new equipment of the same type You are also entitled to convey for disposal small electronic waste products with dimensions of less than 25cm to the premises of electronic retail outlets with sales areas of at least 400m2 free of charge and without any obligation to buy Appropriate differentiated waste collection for the subsequent recycling of the discarded equipment its treatment and its envir...

Page 12: ...info inim biz _ www inim biz Via dei Lavoratori 10 Loc Centobuchi 63076 Monteprandone AP ITALY Tel 39 0735 705007 _ Fax 39 0735 704912 DCMIINE0A2FD1008E 100 20200525 DRAFT ...