Installing Discharge Piping

If it is necessary to install air discharge and condensate discharge piping, adhere
to the following general guidelines. Contact your dealer for more information.

l

Do not use plastic pipe, rubber hose, or lead-tin soldered joints
anywhere in the compressed air system.

l

If an aftercooler, check valve, block valve, or any other restriction is
added to the compressor discharge, install a properly-sized ASME
approved safety/relief valve between the compressor discharge and the
restriction.

l

If you will be using Ingersoll Rand synthetic compressor lubricant, all
downstream piping material and system components must be
compatible. Refer to the following material compatibility list. If there
are incompatible materials present in your system, or if there are
materials not included in the list, contact your dealer or call
1-800-AIR-SERV.

Suitable:

Viton®, Teflon®, Epoxy (Glass Filled), Oil Resistant Alkyd, Fluorosilicone,
Fluorocarbon, Polysulfide, 2-Component Urethane, Nylon, Delrin®, Celcon®,
High Nitrile Rubber (Buna N. NBR more than 36% Acrylonitrile), Polyurethane,
Polyethylene, Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked
Phenolics, Epoxy, Modified Alkyds
(® indicates trademark of DuPont Corporation)

Not Recommended:

Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish,
Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile Rubber
(Buna N. NBR less than 36% Acrylonitrile), EPDM, Ethylene Vinyl Acetate,
Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene Acrylonitrile (San), Butyl

n

General Requirements

The piping, fittings, receiver tank, etc. must be certified safe for at least the
maximum working pressure of the unit. Use hard-welded or threaded steel or
copper pipes and cast iron fittings that are certified safe for the unit’s discharge
pressure and temperature. DO NOT USE PVC PLASTIC. Use pipe thread sealant on
all threads, and make up joints tightly to prevent air leaks.

n

Condensate Discharge Piping

If installing a condensate discharge line, the piping must be at least one size
larger than the connection, as short and direct as possible, secured tightly and
routed to a suitable drain point. Condensate must be disposed of in accordance
with local, state, and federal laws and regulations.

l

All compressed air systems generate condensate which accumulates in
any drain point (e.g. tanks, filters, drip legs, aftercoolers, dryers). This
condensate contains lubricating oil and/or substances which may be
regulated and must be disposed of in accordance with local, state, and
federal laws and regulations.

n

Electrical Wiring

l

Electrical installation and service should be performed by a qualified
electrician who is familiar with all applicable local, state and federal
laws and regulations.

l

This product should be connected to a grounded, metallic, permanent
wiring system, or an equipment-grounding terminal or lead on the
product.

n

General

The motor rating, as shown on the motor nameplate, and the power supply must
have compatible voltage, phase and hertz characteristics.

n

Wire Size

The electrical wiring between the power supply and electric motor varies
according to motor horsepower. Power leads must be adequately sized to protect
against excessive voltage drop during start-up. Information for selecting the
proper wire size and securing connections should be provided with the motor. If
not, refer to the National Electric Code (NEC) or applicable local, state and federal
laws and regulations. If other electrical equipment is connected to the same
circuit, the total electrical load must be considered in selecting the proper wire
size. DO NOT USE UNDERSIZE WIRE.

n

Fuses

Refer to the National Electric Code to determine the proper fuse or circuit breaker
rating required. When selecting fuses, remember the momentary starting current
of an electric motor is greater than its full load current. Time-delay or “slow-blow”
fuses are recommended.

n

Compressor Lubrication

l

Do not operate without lubricant or with inadequate lubricant.
Ingersoll Rand is not responsible for compressor failure caused by
inadequate lubrication.

n

Synthetic Lubricant

We recommend

Ingersoll Rand

synthetic compressor lubricant from start-up.

See the WARRANTY section for extended warranty information.

6

3FW&

EN

NOTICE

Pressure switch

NOTICE

NOTICE

WARNING

AJOUTEZ D’ABORD DE L’HUILE!

• Cette pompe de compresseur est livrée sans 

huile. 

• Ne mettez pas en marche sans lubrifiant ou 

avec un lubrifiant non approprié. 

• N’utilisez pas d’huile de moteur dans la pompe 

de compresseur. 

• Ingersoll-Rand décline toute responsabilité pour 

les pannes d’équipement causées par une 
lubrification insuffisante ou incorrecte. 

• Reportez-vous au mode d’emploi du 

compresseur pour les recommandations 
concernant le lubrifiant du compresseur. 

• Installez correctement
• Vérifiez que l’alimentation électrique est 

adéquate

• Contactez un électricien certifié
• Consultez le manuel d’instructions

AVIS

NOTICE

ADD OIL FIRST!

• This compressor pump is shipped without oil. 
• Do not operate without lubricant or with 

inadequate lubricant.

• Do not use engine oil in the compressor pump.
• Ingersoll-Rand is not responsible for 

equipment failure caused by inadequate or 
incorrect lubrication.

• Refer to the compressor owner's manual for

compressor lubricant recommendations.

• Install properly
• Check for adequate electrical supply
• Contact certified electrician
• Consult instruction manual

PRIMERO, LLENAR DE ACEITE!

• Se entrega esta bomba de compresor sin aceite.
• No hacer funcionar sin aceite ni con aceite 

inadecuado. 

• No poner aceite de motor en la bomba del 

compresor.

• Ingersoll-Rand no será responsable por fallas 

en el equipo debidas a lubricación 
inadecuada o incorrecta. 

• Consultar el manual del compresor en cuanto a 

la lubricación recomendada.

• Instalar correctamente
• Verificar que la alimentación eléctrica 

sea adecuada

• Consultar un electricista certificado
• Referirse al manual de instrucciones

AVISO

56289655-01

WARNING

C

A

UT

I

O

N

Wiring schematic

RELEASED 31/Jan/2020 19:25:50 GMT

Summary of Contents for SS4L5

Page 1: ...Instructions Owner s Manual Manual del usuario ES Manuel de l utilisateur FR Owner s Manual EN Single Stage Reciprocating Air Compressor Model SS4L5 80448251 Revision BOVBSZ 20 RELEASED 31 Jan 2020 19...

Page 2: ...ANATION OF SAFETY SIGNAL WORDS Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided...

Page 3: ...ETIRADO EL PROTECTOR LA MAQUINA PUEDE EMPEZAR A FUNCIONAR AUTOMATI CAMENTE DESCONECTE LA ENERGIA ANTE DE DARLE SERVISIO A LA MAQUINA BLOQUEAR ETIQUETAR LA MAQUINA PIECES TOURNANTES PEUT CAUSER DES BLE...

Page 4: ...4 3FW EN General Arrangement INSTALLATION RELEASED 31 Jan 2020 19 25 50 GMT...

Page 5: ...0 0 0 0 8 0 1 0 0 8 0 1 0 1 0 0 0 0 0 0 91 0 8 9 0 8 9 1 1 0 9 1 0 9 2 2 f 9 9 9 9 92 9 B 9B N9 9 9 9 9 9MS9 9 93 0 1 1 0 G 9 9 9 9 9 9 9 9 9 96 9 9 92 93 9 7 N 9 9 9 9 92 9 9 9 9 9 9 Q 9 9 9 9 9 9 9...

Page 6: ...n General The motor rating as shown on the motor nameplate and the power supply must have compatible voltage phase and hertz characteristics n Wire Size The electrical wiring between the power supply...

Page 7: ...to service for the first time 1 Set the pressure switch lever A to OFF 2 Open the service valve fully to prevent air pressure from building in the tank A Open B Closed 3 Move the pressure switch lever...

Page 8: ...all a new filter element and replace the housing securing it in place with the wing nut previously removed n Oil Change 1 Remove the oil drain plug C and allow the lubricant to drain into a suitable c...

Page 9: ...To arrange a tank inspection contact the nearest Ingersoll Rand service provider If the tank has not been inspected within the first 10 years of compressor service the tank must be taken out of servi...

Page 10: ...oltage and upgrade lines as required Contact electrician 4 Inspect valves Clean or replace as required Install valve kit 5 Inspect bearings and replace crankshaft assembly if required Unit is slow to...

Page 11: ...r overload heaters Contact electrician 5 Contact power company Moisture in crankcase or milky appearance in petroleum lubricant or rusting in cylinders 1 Detergent type lubricant being used 2 Extremel...

Page 12: ...l with proper lubricant 2 Drain existing lubricant and refill with proper lubricant 3 Install ring kit 4 Adjust piston rings 5 Repair or replace as required 6 Deglaze cylinder with 180 grit flex hone...

Page 13: ...pecifically excluded from the company s warranty In the event performance warranties are expressly included the company s obligation shall be to correct in the manner and for the period of time provid...

Page 14: ...3FW 41 NOTES RELEASED 31 Jan 2020 19 25 50 GMT...

Page 15: ...42 3FW NOTES RELEASED 31 Jan 2020 19 25 50 GMT...

Page 16: ...3FW 43 NOTES RELEASED 31 Jan 2020 19 25 50 GMT...

Page 17: ...ingersollrandproducts com 20 Ingersoll Rand RELEASED 31 Jan 2020 19 25 50 GMT...

Reviews: