SYNTHETIC COMPRESSOR LUBRICANT MATERIAL COMPATIBILITY 

LIST

COMPATIBILITY LIST SUITABLE :

FKM (Fluoroclastomer), PTFE, Epoxy (Glass Filled), Oil Resistant Alkyd, 

Fluorosilicone, Fluorocarbon, Polysulfide, 2-Component Urethane, 

Nylon, POM (Polyoxymethylene/Polyacctel), High Nitrile Rubber (Buna 

N�� NBR more than 6% Acrylonitrile), Polyurethane, Polyethylene, 

Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked 

Phenolics, Epoxcy, Modified Alkyds (® indicates trademark of DuPont 

Corporation)��

 

NOT RECOMMENDED :

Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish, 

Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile 

Rubber (Buna N�� NBR less than 6% Acrylonitrile), EPDM, Ethylene Vinyl 

Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene Acrylonitrile 

(San), Butyl��

GENERAL REQUIREMENTS 

The piping, fittings, air receiver tank, etc�� must be certified safe for at least 

the maximum working pressure of the unit�� Use hard-welded or threaded 

steel or copper pipes and cast iron fittings that are certified safe for the 

unit’s discharge pressure and temperature�� DO NOT USE PVC PLASTIC�� Use 

pipe thread sealant on all threads, and make up joints tightly to prevent air 

leaks��

CONDENSATE DISCHARGE PIPING 

If installing a condensate discharge line, the piping must be at least one 

size larger than the connection, as short and direct as possible, secured 

tightly and routed to a suitable drain point �� Condensate must be disposed 

of in accordance with local, state, and federal laws and regulations��

NOTICE

All compressed air systems generate condensate which 

accumulates in any drain point (e��g�� tanks, filters, drip legs, 

aftercoolers, dryers)�� This condensate contains lubricating 

oil and/or substances which may be regulated and must be 

disposed of in accordance with local, state, and federal laws and 

regulations��

ELECTRICAL WIRING

WARNING

Electrical installation and service should be performed by a 

qualified electrician who is familiar with all applicable local, state 

and federal laws and regulations��

NOTICE

This product should be connected to a grounded, metallic, 

permanent wiring system, or an equipment-grounding termlnal 

or lead on the product��

GENERAL 

The motor rating, as shown on the motor nameplate, and the power 

supply must have compatible voltage, phase and hertz characteristics��

WIRE SIZE 

The electrical wiring between the power supply and electric motor varies 

according to motor horsepower�� Power leads must be adequately sized 

to protect against excessive voltage drop during start-up�� Information 

for selecting the proper wire size and securing connections should be 

provided with the motor�� If not, refer to the National Electric Code (NEC) or 

applicable local, state and federal laws and regulations�� If other electrical 

equipment is connected to the same circuit, the total electrical load must 

be considered in selecting the proper wire size�� DO NOT USE UNDERSIZE 

WIRE�� 

FUSES 

Refer to the National Electric Code to determine the proper fuse or circuit 

breaker rating required�� When selecting fuses, remember the momentary 

starting current of an electric motor is greater than its full load current�� 

Time-delay or “slow-blow” fuses are recommended��

Single-Phase Wiring

T = Supply Line Terminal

L = Load Terminal

Fused disconnect or circuit breaker

Pressure switch

(includes on/auto-off switch)

Single phase

motor

COMPRESSOR LUBRICATION

CAUTION

Do not operate without lubricant or with inadequate lubricant�� 

Ingersoll Rand is not responsible for compressor failure caused 

by inadequate lubrication��

SYNTHETIC  LUBRICANT 

We recommend 

Ingersoll Rand

  synthetic compressor lubricant from 

start-up�� See the WARRANTY section for extended warranty information�� 

ALTERNATE LUBRICANTS 

You may use a petroleum-based lubricant that is premium quality, does 

not contain detergents, contains only anti-rust, anti-oxidation, and anti-

foam agents as additives, has a flashpoint of 440°F (227°C) or higher, and 

has an auto-ignition point of 650°F (4°C) or higher��

See the petroleum lubricant viscosity table below�� The table is intended 

as a general guide only�� Heavy duty operating conditions require 

heavier viscosities�� Refer specific operating conditions to your dealer for 

recommendations��

Temperature 

Around Compressor

Viscosity at 100

°

F

(37��8 

°

C)

Viscosity Grade

°F

°C

SUS

Centistokes

ISO

SAE

40 & 

below

4��4 & 

below

150

2

2

10

 40-80

4��4-26��7

500

110

100

0

   80-125

26��7-51��0

750

165

150

40

If you use a petroleum-based compressor lubricant at start-up and decide 

to convert to 

Ingersoll Rand

 synthetic compressor lubricant later on, the 

compressor valves must be thoroughly decarbonized and the crankcase 

must be flushed before conversion�� 

 62215.10.56

Summary of Contents for SS3L3

Page 1: ...n B May 2015 Save These Instructions SS3L3 Owner s Manual with Parts List Owner s Manual With Parts List EN Manual del propietario con la lista de piezas ES Manuel du propri taire avec liste des pi ce...

Page 2: ...WIRE SIZE 7 FUSES 7 COMPRESSOR LUBRICATION 7 SYNTHETIC LUBRICANT 7 ALTERNATE LUBRICANTS 7 FILLING PROCEDURES 8 INITIAL START UP 8 PRESSURE SWITCH 8 OPERATION 9 GENERAL 9 NORMAL START UP 9 WHEN YOU ARE...

Page 3: ...22204929 Rev B EN EN May 2015 62215 10 56...

Page 4: ...jury Do not operate with guards removed Machine may start automatically Disconnect power before servicing Lockout tagout machine Hot surfaces Can cause serious injury Do not touch Allow to cool before...

Page 5: ...tion for the carrier s inspection Delivery receipts that have been signed without a notation of damage or missing parts are considered to be delivered clear Subsequent claims are then considered to be...

Page 6: ...NG Remove the unit from the skid before mounting The unit must be permanently mounted When mounting the unit bolt the feet to a firm level foundation such as a concrete floor Do not bolt uneven feet t...

Page 7: ...he power supply must have compatible voltage phase and hertz characteristics WIRE SIZE The electrical wiring between the power supply and electric motor varies according to motor horsepower Power lead...

Page 8: ...itch to the point of failure and or void any warranty for the Pressure Switch Follow this procedure before putting the unit into service for the first time Set the pressure switch lever to OFF Pressur...

Page 9: ...ervice valve Attach hose and accessory Move the pressure switch lever to ON AUTO The unit will start Allow tank pressure to build The motor will stop when tank pressure reaches cut out pressure Open t...

Page 10: ...e beltguards and covers are securely in place Ensure area around compressor is free from rags tools debris and flammable or explosive materials Weekly Inspect air filter element Clean or replace if ne...

Page 11: ...heave are properly aligned and the motor anchor screws are adequately retightened prior to restarting the compressor 1 2 CAUTION Improper pulley sheave alignment and belt tension can result in motor o...

Page 12: ...scored Repair or replace as required Defective safety relief valve Replace Unit does not come up to speed Loose beltwheel or motor pulley excessive end play in motor shaft or loose drive belts Check...

Page 13: ...Drain existing lubricant and refill with proper lubricant Detergent type lubricant being used Drain existing lubricant and refill with proper lubricant Piston rings damaged or worn broken rough or scr...

Page 14: ...or contact on motor terminals or starter connections Ensure good contact on motor terminals or starter connections Improper starter overload heaters Install proper starter overload heaters Contact ele...

Page 15: ...or end gaps not staggered Adjust piston rings Cylinder s or piston s scratched worn or scored Repair or replace as required Worn cylinder finish Deglaze cylinder with 180 grit flex hone Excessive cond...

Page 16: ...EN 16 22204929 Rev B EN WARRANTY 62215 10 56...

Page 17: ...22204929 Rev B EN 17 EN SS SS3 BARE PARTS LIST 62215 10 56...

Page 18: ...16 54375977 lWASHER M8 1 17 54440045 lCAPSCREW M8 X 20 LEFT HAND THREAD 1 18 49812050 ASSEMBLY OIL FILL PLUG 1 19 NSS lPLUG OIL FILL 1 20 95024394 lO RING OIL FILL PLUG 1 21 97330468 ASSEMBLY PISTON P...

Page 19: ...2 GLASS SIGHT 1 45 97330690 HEAD 1 46 70243936 ASSEMBLY VENT 1 47 70243399 FILTER INLET 1 NI 70243712 lELEMENT FILTER 1 NSS NOT SOLD SEPARATELY AVAILABLE lNDlVlDUALLY OR IN VALVE KIT 97338107 X AVAILA...

Page 20: ...EN 20 22204929 Rev B EN SS3L3 PARTS LIST 62215 10 56...

Page 21: ...CONNECTOR MALE 1 2 X 3 8 1 11 97336127 ASSY DISCHARGE TUBE 1 2 1 12 97336135 ASSY VENT TUBE 1 4 1 AIR RECEIVER TANK GROUP 13 32027120 VALVE MANUAL DRAIN 1 14 32106551 VALVE BALL 1 2 F F SERVICE VALVE...

Page 22: ...ll external crankcase heater kit is intended for aftermarket use Part No Description 97330385 Kit Crankcase Heater VIBRATION ISOLATOR PADS Vibration Isolator pads are designed to absorb 20 40 of the s...

Page 23: ...62215 10 56...

Page 24: ...ingersollrandproducts com 2015 Ingersoll Rand 62215 10 56...

Page 25: ...015 Guarde estas instrucciones SS3L3 Manual del propietario con la lista de piezas Manual del propietario con la lista de piezas ES Manuel du propri taire avec liste des pi ces FR Owner s Manual with...

Page 26: ...O DEL CABLE 7 FUSIBLES 7 LUBRICACI N DEL COMPRESOR 7 LUBRICANTE SINT TICO 7 OTROS LUBRICANTES 7 PROCEDIMIENTOS DE LLENADO 8 ARRANQUE INICIAL 8 OPERACI N 9 GENERALIDADES 9 ARRANQUE NORMAL 9 PARADA 9 MA...

Page 27: ...22204929 Rev B ES ES May 2015 62215 10 56...

Page 28: ...autom ticamente Desconecte la energ a ante de hacer mantenimiento Bloquee etiquete la m quina SUPERFICIES CALIENTES Pueden causar lesiones graves No tocar Deje enfriar antes de hacer mantenimiento No...

Page 29: ...lugar de recepci n para la inspecci n del transportista Los recibos de entrega firmados que no tienen anotaci n de da os o piezas faltantes se consideran como prueba de una entrega sin problemas Cualq...

Page 30: ...ADVERTENCIA Antes del montaje retire la unidad de los patines El compresor debe ser montado permanentemente Emperne la compresor a una base nivelada y firme como un piso de concreto No apriete excesi...

Page 31: ...espondientes AVISO Este producto se debe conectar a un sistema de cableado permanente conectado a tierra y met lico o a una terminal a tierra de un equipo o polo GENERALIDADES La capacidad nominal del...

Page 32: ...r de presi n no se debe tratar de forzar con de ninguna manera y ninguna tentativa no se debe hacer para ajustar los ajustes de la presi n pues sta podr a da ar el interruptor al punto de la falta y o...

Page 33: ...del disyuntor neumatico en ONIAUTO La unidad se arranque Perrnite que la presi n del tanque receptor aumenta El motor se para cuando la presi n del tanque receptor se Ilenara a la presion de corle Abr...

Page 34: ...n sujetos en su lugar Asegurese de que el area alrededor del compresor est6 libre de trapos herramientas escombros y materiales inflamables o explosivos Semanalmente Revise el elemento del filtro de a...

Page 35: ...Inches Min Tension Lbs Max Tension Lbs 0 17 3 0 6 0 Antes de volver a poner en marcha el compresor compruebe que lapolea y la roldana est n adecuadamente alineadas y que los tornillos de anclaje del m...

Page 36: ...dad deseada Rueda de la banda o polea del motor de partida sueltas juego excesivo en el eje del motor o bandas de la transmisidn sueltas Revise la tension y alineacion de la rueda de la banda polea de...

Page 37: ...te y vuelva a llenar con uno adecuado Se esta usando lubricante tipo detergente Drene el lubricante y vuelva a llenar con uno adecuado Anillos del piston danados o gastados rotos rugosos o rayados Esp...

Page 38: ...l motor o conexlones del arrancador Calefactores incorrectos de sobrecarga del arrancador lnstale calefactores correctos de sobrecarga del arrancador Comunlquese con un electricista Deficiente regulac...

Page 39: ...nes rayados gastados o cortados Repare o reemplace segtin sea necesario Capa superficial del cilindro desgastada Limpie el cilindro con flex hone de 180 grhnulos Condensacidn excesiva en tanque recept...

Page 40: ...ES 16 22204929 Rev B ES GARANT A 62215 10 56...

Page 41: ...22204929 Rev B ES 17 ES SS3 BARE LISTADO DE COMPONENTES 62215 10 56...

Page 42: ...CADO PARA RELLENO DE LUBRICANTE 1 19 NSS lTAPON ROSCADO PARA RELLENO DE LUBRICANTE 1 20 95024394 lJUNTA TORICA TAPON ROSCADO PARA RELLENO DE LUBRICANTE 1 21 97330468 CONJUNTO DE PISTON Y PASADOR 2 22...

Page 43: ...VENDE POR SEPARADO NON VENDU SEPAREMENT AVAILABLE lNDlVlDUALLY OR IN VALVE KIT 97338107 DlSPONlBLE INDIVIDUALMENTE O EN CONJUNTO DE VALVULA 97338107 VENDU SEPARlMENT OU DANS L ENSEMBLE DE CLAPETS 973...

Page 44: ...ES 20 22204929 Rev B ES SSL3 LISTADO DE COMPONENTES 62215 10 56...

Page 45: ...R MACHO 1 2 X 3 8 1 11 97336127 CONJUNTO TUBO DE DESCARGA 1 2 1 12 97336135 CONJUNTO TUBO DE VENTILACI N 1 GRUPO TANQUE RECEPTOR DE AIRE 13 32027120 V LVULA PURGA MANUAL 1 14 32106551 V LVULA DE BOLA...

Page 46: ...talacion esta destinado a su uso de postventa N0 DE PIEZA DESCRIPCI N 97330385 JUEGO CALEFACTOR DEL CARTER Las almohadillas aisladoras de vibraci n est n dise adas para absorber el 40 al 60 del sonido...

Page 47: ...62215 10 56...

Page 48: ...ingersollrandproducts com 2015 Ingersoll Rand 62215 10 56...

Page 49: ...Veuillez conserver ces instructions SS3L3 Manuel du propri taire avec liste des pi ces Manual del propietario con la lista de piezas ES Manuel du propri taire avec liste des pi ces FR Owner s Manual w...

Page 50: ...MPRESSEUR 7 LUBRIFIANT SYNTH TIQUE 7 LUBRIFIANTS DE RECHANGE 7 PROC DURES DE REMPLISSAGE 8 MISE EN MARCHE INITIALE 8 MANO CONTACT 8 OP RATION 9 G N RALIT S 9 D MARRAGE NORMAL 9 LORSQUE VOUS AVEZ FINI...

Page 51: ...22204929 Rev B FR FR May 2015 62215 10 56...

Page 52: ...automatiquement D brancher avant le service Verrouiller tiqueter la machine SURFACE CHAUDE Peut causer des blessures graves Ne pas toucher Attendre le refroidissement avant de r parer Ne pas toucher...

Page 53: ...pect par le transporteur Les bons de livraison qui ont t sign s sans notation de dommage ou pi ces manquantes sont consid r s comme faisant tat d une livraison parfaite Toute demande d indemnit ult ri...

Page 54: ...MANENT AVERTISSEMENT Avant du montage enlever le compresseur de la cale Le compresseur doit tre mont en permanence Lors du montage du compresseur verrouiller les pieds une base solide nivel e comme un...

Page 55: ...ar un lectricien agr qui conna t les lois et les r glements municipaux provinciaux et f d raux en vigueur AVIS Cet unit doit tre connect e une syst me de c blage permanente m tallique mise la terre ou...

Page 56: ...ures de remplissage MISE EN MARCHE INITIALE MANO CONTACT Le mano contact est pr r gl la pression exig e Les arrangements de gamme et de diff rentiel NE SONT PAS r glables Le mano contact ne devrait pa...

Page 57: ...Laisser augmenter la pression dans le r servoir Le moteur s arr tera quand la pression dans le r servoir atteint la pression de disjonction Ouvrir la soupape de service Le compresseur est pr t pour l...

Page 58: ...chiffons d outils de debris et de matihres inflammables ou explosives Une fois par semaine Inspecter les elements filtrants du fiitre d aspiration Les nettoyer au besoin Une fois par mois Verifier s...

Page 59: ...pouches Min Tension Lbs Max Tension Lbs 0 17 3 0 6 0 Avant de faire d marrer le compresseur assurer l alignement exact du centre des rainures de la poulie motrice et du volant ainsi que le serrage de...

Page 60: ...ange segments et jolnts Les segments sont hors de leur logement ou coinces dans leurs gorges ou leurs coupes ne sont pas decalees Ajuster les segments Les cylindres ou les pistons sont egratignes uses...

Page 61: ...es paliers et les remplacer au besoin Fuite de la soupape de surete ou sigge de soupape use Remplacer la soupape de s0rete Arrets et demarrages trop frequents Fuites d air dans les canalisations de re...

Page 62: ...briflant actuel et le remplacer par un lubriflant qui convient Cycles de marche extremement legers Falre fonctlonner le compresseur par cycles plus longs Le compresseur est situe dans un lieu humide D...

Page 63: ...placer par un lubrifiant qui convient Segments de pistons endommages ou uses casses rugueux ou egratignes Coupe ou degagement lateral trop grand Installer une trousse de rechange segments et joints Le...

Page 64: ...FR 16 22204929 Rev B FR GARANTIE 62215 10 56...

Page 65: ...22204929 Rev B FR 17 FR SS3 POUR LISTE DES PI CES 62215 10 56...

Page 66: ...HE 1 18 49812050 ENSEMBLE DE BOUCHON DE REMPLISSAGE D HUILE 1 19 NSS lBOUCHON DE REMPLISSAGE D HUILE 1 20 95024394 lJOINT TORIQUE DE BOUCHON DE REMPLISSAGE D HUILE 1 21 97330468 ENSEMBLE DE PISTON ET...

Page 67: ...DE POR SEPARADO NON VENDU SEPAREMENT AVAILABLE lNDlVlDUALLY OR IN VALVE KIT 97338107 DlSPONlBLE INDIVIDUALMENTE O EN CONJUNTO DE VALVULA 97338107 VENDU SEPARlMENT OU DANS L ENSEMBLE DE CLAPETS 9733810...

Page 68: ...FR 20 22204929 Rev B FR SS3L3 LISTE DES PI CES 62215 10 56...

Page 69: ...RACCORDS 10 95083192 CONNECTEUR M LE 1 2 X 3 8 1 11 97336127 CANALISATION DE REFOULEMENT 1 2 PO 1 12 97336135 VENT 1 4 1 GROUPE R SERVOIR D AIR 13 32027120 PURGEUR MANUEL 1 14 32106551 ROBINET TOURNAN...

Page 70: ...ur du carter principal est fournie pour utilisation post vente N DE PIECE DESCRIPTION 97330385 TROUSSE CHAUFFAGE DU CARTER PRINCIPAL TAMPONS AMORTISSEURS ANTIVIBRATIONS Les tampons amortisseurs antivi...

Page 71: ...62215 10 56...

Page 72: ...ingersollrandproducts com 2015 Ingersoll Rand 62215 10 56...

Reviews: