L-Series Service Manual
8
FUNCTIONS
ANSI/BHMA A156.13, 1994, Series 1000, Grade 1
Trim
Assembly
Page Number
Lock
Assembly
Page Number
Lock Case
Page Number
Keyed Locks
SCHLAGE
ANSI
LV9080EU
Electrically Unlocked (Fail Secure) with Vandlgard
®
a
Outside knob/lever is continuously unlocked. Latchbolt is retract-
ed by key outside or by knob/lever inside. Inside knob/lever is
always free for immediate exit. Auxiliary latch deadlocks latchbolt
when door is closed. Vandlgard function allows exterior lever to
rotate freely down, while remaining securely locked.
24
63
L283-175
L9080EL-RX
Request to Exit Electrically Locked (Fail Safe)
Same as L9080EL function. In addition, a microswitch
positioned inside the lock case is activated when either inside
or outside knob/lever is rotated. The switch signals the use of
that opening to security systems, allowing a non-disruptive
means of immediate exit. Specify L283-263.
(Previously XL11-807)
24
60
L283-142
per L283-263
L9080EU-RX
Request to Exit Electrically Unlocked (Fail Secure)
Same as L9080EU function. In addition, a microswitch posi-
tioned inside the lock case is activated when either inside or
outside knob/lever is rotated. The switch signals the use of that
opening to security systems, allowing a non-disruptive means
of immediate exit. Specify L283-263. (Previously XL11-807).
24
62
L283-143
per L283-263
L9082
Institution Lock*
Latchbolt is retracted by key on either side. Knob/lever on both
sides is always inoperative. Auxiliary latch deadlocks latchbolt
when door is closed.
23
64
L283-146
LV9082
Institution Lock* with Vandlgard®
Latchbolt is retracted by key on either side. Inside and outside
knob/lever are always inoperative. Auxiliary latch deadlocks
latchbolt when door is closed. Vandlgard function allows exterior
lever to rotate freely down while remaining securely locked.
23
65
L283-182
L9082EL
Electrically Locked (Fail Safe) Both Sides
a
Outside and inside knob/lever are continuously locked. Latchbolt
is retracted by key on either side. Switch or power failure allows
inside and outside knob/lever to retract latchbolt. Auxiliary latch
deadlocks latchbolt when door is closed. (Previously XL11-452).
25
66
L283-085
L9082EU
Electrically Unlocked (Fail Secure) Both Sides*
a
Outside and inside knob/lever are continuously unlocked.
Latchbolt is retracted by key on either side. Switch or power
failure prevents retraction of latchbolt by inside and outside
knob/lever. (Previously XL11-452).
25
67
L283-086
L9453
F20
Entrance Lock
a
Latchbolt is retracted by knob/lever from either side unless out-
side is locked by 20° rotation of thumbturn. Deadbolt is thrown or
retracted by 90° rotation of thumbturn. When locked, key outside
or knob/lever inside retracts deadbolt and latchbolt simultane-
ously. Outside knob/lever remains locked until thumbturn is re-
turned to vertical position. Throwing deadbolt automatically locks
outside knob/lever. Auxiliary latch deadlocks latchbolt when door
is closed. Inside knob/lever is always free for immediate exit.
22
73
L283-137
*Caution: Double cylinder locks on residences–or on any door in any structure which are used for egress–are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
Not sold separately as a part.