background image

DELAYED EGRESS
18 SERIES RIM PANIC
AND FIRE EXIT DEVICES

DX-F-18-R

Date:

D-1400-4

3-06-2008

DX-18-R

INSTALLATION INSTRUCTIONS

1

PARTS CHECK

1

1.1.

MAKE SURE THE CORRECT DEVICE AND TRIM (IF APPLICABLE) ARE BEING USED AND ARE THE
CORRECT HAND (SEE PAGE 11 FOR REVERSING INSTRUCTIONS).

1.2.

MAKE SURE ALL NEEDED PARTS ARE ON HAND.

NOTE:

LIST DOES NOT REFLECT ALL POSSIBLE APPLICATIONS.

1) DX-(F)-18-R DEVICE

NOTE:

 SEE PAGE 13 FOR HANDING.

2) STRIKE

570 STD.

PANIC

F-570 STD.

FIRE

F-490 OPT.

FIRE

565 OPT.

PANIC

579 OPT.

PANIC

490 OPT.

PANIC

3) KNOB HUB

FOR KNOB (KE)
AND LEVER (LE)
TRIMS (1 QTY.)

4) POWER SUPPLY (DEX)

WIRING

DIAGRAM

2.0 A FUSE

DELAYED EGRESS

MODULE (DXM)

5) POWER TRANSFER HINGE

8 WIRE, 1.5 A MINIMUM RATED

MUST BE U.L. APPROVED
NOTE:

SUPPLIED BY OTHERS.

6) 18-20 A.W.G. WIRE

NOTE:

SUPPLIED BY OTHERS.

7) 1-1/4” MORTISE CYLINDER

MUST HAVE STANDARD “A” CAM
(APPROX. 5/16” WIDE X 3/4”
LONG); LONGER CYLINDERS
REQUIRE BLOCKING RINGS.

NOTE:

SUPPLIED BY OTHERS.

8) INTERFACE

BOARD AND
CABLE

Copyright © 2006 Ingersoll-Rand Company Limited

9) DX DEVICE

SCREW PACK

#10-24 X 3/8”

PPHMS W/NYLOC

PATCH (2 QTY.)

1/4-20 X 3/4”

TPHMS (1 QTY.)

#10-24 X 3/4”

FPHMS (3 QTY.)

#10-24 X 1”

PPHMS (4 QTY.)

#10-24 X 1-1/2”

PPHMS (2 QTY.)

SEX BOLT, 1/4-20

THREAD (1 QTY.)

CYLINDER NUT

(1 QTY.)

CYLINDER

BRACKET

(1 QTY.)

MOUNTING

BRACKET

(1 QTY.)

CHANNEL

END CAP

(1 QTY.)

CYLINDER LOCK

WASHER (1 QTY.)

#6-32 X 1/4”

PPHMS (4 QTY.)

Summary of Contents for Monarch 18 Series

Page 1: ...IMS 1 QTY 4 POWER SUPPLY DEX WIRING DIAGRAM 2 0 A FUSE DELAYED EGRESS MODULE DXM 5 POWER TRANSFER HINGE 8 WIRE 1 5 A MINIMUM RATED MUST BE U L APPROVED NOTE SUPPLIED BY OTHERS 6 18 20A W G WIRE NOTE S...

Page 2: ...3 1 1 2 490 3 4 4023 2 570 3 1 4 4 1 4 4023 2 579 2 5 8 3 5 8 4023 2 565 3 4 4023 2 490 3 1 4 4 1 4 F4023 2 F 490 3 1 4 4 1 4 F4023 2 F 570 3 1 4 4 1 4 VERTICAL C DOUBLE DOOR INSTALLATION WITH MONARCH...

Page 3: ...0 1 2 44 1 2 DEVICE TOUCHBAR LENGTH DEVICE LENGTH LHR SHOWN SHORTTOUCHBAR W LONG CHANNEL 3 DOOR AND HARDWARE PREPARATION C DEVICE REF L CVERTICAL L 3 8 DIA HOLE 4 PLACES C DEVICE REF L C VERTICAL L 1...

Page 4: ...IN CHANNEL COVER A DRILL 11 16 HOLE AS SHOWN BELOW LEFT B REMOVE MATERIALAS SHOWN BELOW RIGHT REMOVE BURRS X CUT OFF LENGTH Y 1 RECOMMENDED 8 3 4 MINIMUM 3 9 IF DEVICE IS LONGER THAN X USE A HACKSAW...

Page 5: ...HROUGH DOOR SKIN ON DEVICE SIDE OF DOOR ONLY WARNING THERE ARE NO SERVICEABLE PARTS IN THE POWER SUPPLY DEX OR IN THE DELAY MECHANISM THE REQUEST TO EXIT SWITCH INSIDE THE DEVICE IS PRESET AT THE FACT...

Page 6: ...LL MORTISE CYLINDER UPSIDE DOWN 4 7 INSTALL INTERFACE BOARD TO CYLINDER BRACKET 6 32 X 1 4 PPHMS 4 PLACES LHR SHOWN 4 8 SLIDE CHANNEL COVER HALF WAY INTO CHANNEL 4 9 CONNECT COILCONNECTOR TO INTERFACE...

Page 7: ...NTING BRACKET INTO CHANNEL MOUNTING BRACKET SEX BOLT 1 4 20 X 3 4 TPHMS MOUNTING SCREW CAUTION BE CAREFUL NOT TO PINCH OR CUT WIRES DURING INSTALLATION INTERFACE BOARD CABLE 4 14 MOUNT POWER SUPPLY DE...

Page 8: ...MAGNET 24 VDC 4 BLACK COMMON 5 YELLOW GREEN LED 6 ORANGE RED LED AUDIBLE 7 N A DRY ALARM CONTACT COM 8 N A DRY ALARM CONTACT N O 9 N A DRY ALARM CONTACT N C 10 WHITE LEDS AUDIBLE 24 VDC 11 WIRE COLOR...

Page 9: ...ENTER PUNCH DRILL AND TAP STRIKE MOUNTING SCREW HOLES 4 21 INSTALL STRIKE LHR SHOWN L L DIM A DEVICE REF C L 10 24 X 3 4 FPHMS 3 PLACES 570 STRIKE SHOWN DIM B STRIKE DIM A DIM B 570 2 2 490 2 1 1 2 56...

Page 10: ...TIMES NUISANCE ALARM DEPRESS THE TOUCHBAR FOR LESS THAN 3 SECONDS THEN RELEASE THE LED IS SOLID GREEN AND RED AND HORN SOUNDS A MONOTONE AT THIS TIME THE DELAY EGRESS PROCESS HAS NOT STARTED AND THE D...

Page 11: ...HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CANNOT BE RE HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CANNOT BE RE HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CAN...

Page 12: ...ING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING 1 1 1 1 1 REMOVEBACKPLATESUB ASSEMBLY...

Page 13: ...CONTACTS FIRE ALARM JUMPER FUNCTION EXIT DEVICE UNLOCKS IMMEDIATELY UPON A FIRE ALARM ALARM DRYCONTACTS 1 ATTACH COMMON COM WIRE TO DELAYED EGRESS MODULE TERMINAL 8 2 ATTACH NORMALLY OPEN N O WIRE TO...

Page 14: ...E AND DEVICE LEDS HORN MAGNET POSSIBLE SWITCHED CONDITION CHANGES FIRE ALARM OFF OFF OFF ARMED CONTACT OPEN ARMED SOLID GREEN OFF ON SW1 TO BYPASS SW2 TO LOCALBYPASS TOUCHBAR SW TO NUISANCE LOCALBYPAS...

Page 15: ...1 13 16 3 7 8 7 3 4 2 13 16 3 3 16 DEVICE REF C L DX F 18 R DRILLING TEMPLATE RHR VERTICAL C L 3 1 8 1 9 16 5 8 DIA HOLE x 1 2 DEEP E 1 1 4 DIA HOLE B 5 8 DIA HOLE x 1 2 DEEP E DRILLAND TAP FOR 10 24...

Page 16: ...HOLE D 1 4 2 1 2 1 13 16 3 7 8 7 3 4 2 13 16 3 3 16 DEVICE REF C L DX F 18 R DRILLING TEMPLATE LHR VERTICAL C L 1 9 16 3 1 8 5 8 DIA HOLE x 1 2 DEEP E 5 8 DIA HOLE x 1 2 DEEP E DRILLAND TAP FOR 10 24...

Reviews: