MAINTENANCE
MAINTENANCE SCHEDULE
Hours:
Daily
150
(1st time
only)
Every 500
Every 2000
Every 4000
Every 6000
Every 8000
Every
16000
Oil filter
Change
Change †
Change
Change
Air filter **
Check
Pressure
Change
Check
Pressure
Change
Change
Premium Coolant (Ultra)*
Check
Sample
Sample
Sample
Change
Change
Extended life
Premium Coolant (Ultra EL)*
Check
Sample
Sample
Sample
Sample
Change
Power Drive Module filter *
Check
Change
Change
Change
Change
Change
Hoses ***
Check/ clean
Check/clean Check/clean Check/clean Check/clean
Pressure relief valve
Check
Check
Check
Check
Check
Cooler Core(s)
Check / clean
Check / clean Check/clean Check/clean Check/clean Check/clean
Moisture separator
Check / clean
Check / clean Check/clean Check/clean Check/clean Check/clean
Motor cowl
Check / clean
Check / clean Check/clean Check/clean Check/clean Check/clean
Vibration Analysis
Analysis
Analysis
Analysis
Analysis
Analysis
Coolant Analysis
Analysis
Analysis
Analysis
Analysis
Analysis
Blower Motor (N90 − 160K / 125 −
200H Only)
Re-grease
Regrease
Re-grease
Expansion joint bolt torque (if
supplied)
Check
Check
Check
Check
Check
Check
Condensate stainers
Clean
Clean
Clean
Clean
Clean
Clean
Check valve
Inspect
Replace
Replace
Blowdown valves
Inspect
Rebuild
Rebuild
Airend intake batts **
Check
Check
Check
Breather
Check
Check
Check
Check
Check
Food Grade Lubricant (Ultra FG)*
Check
Analysis
(Every 1000)
Change
If the compressor is run less than 4,000 hours per year,
* Maintain every 6 months
** Maintain every year
*** Maintain every 2 years
† Change filter if changing Food Grade Lubricant (
Ultra FG)
MAINTENANCE PROMPTS
The service warning and flashing LED will appear at intervals,
dependent on the service level selected. Refer to operating
instructions.
The customer can only reset the warning for 24 hours by
pressing the “set” button.
IR service engineers will master reset the warning after
completing the service work.
The service warning will return each subsequent 2000 hours.
The machine will be master reset after service work
conducted prior to the 2000 hour interval to prevent false
indication.
MAINTENANCE CHART
The MAINTENANCE CHART indicates the various components
and the intervals when maintenance has to take place. Where
a service interval is stated in both hours and months, it is the
sooner of the two intervals that must be adhered to. Coolant
capacities etc can be found in the
Product information sheet
.
Note that any Local or National codes that require specific
maintenance that exceeds the requirements of this section
must be adhered to.
RELEASED 06/Feb/2018 13:48:37 GMT