background image

650941- X- B

PUMP OPTION DESCRIPTION CHART

650941--X

PACKING MATERIAL

PLUNGER TYPE

SPRING ARRANGEMENT

PACKING MATERIAL

(PACKINGS ARE UPPER AND LOWER UNLESS NOTED)

C

UHMW--PE

P

UHMW--PE/PTFE STAG’D (UPPER)

F

UHMW--PE/LEATHER STAG’D (UPPER)

UHMW--PE (LOWER)

UHMW--PE (LOWER)

R

PTFE/UHMW--PE STAG’D (UPPER)

J

POLYURETHANE (UPPER)

PTFE (LOWER)

UHMW--PE (LOWER)

3

GLASS FILLED PTFE

SPRING ARRANGEMENT

3

NO SPRING

4

MULTIPLE WAVE SPRING

PLUNGER TYPE

4

CS HD CHROME PLATING

X 4 --B

GENERAL DESCRIPTION

WARNING

HAZARDOUS PRESSURE. Do not exceed maxi-

mum operating pressure of 2668 psi (184 bar) at 2000 psi (138

bar) inlet hydraulic pressure.

PUMP RATIO X

MAXIMUM PUMP

INLET PRESSURE TO PUMP MOTOR

=

FLUID PRESSURE

Pump ratio is an expression of the relationship between the pump motor area and the

lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied

to the motor of a 5:1 ratio pump it will develop a maximum of 750 p.s.i. (52 bar) fluid pres-

sure (at no flow) -- as the fluid control is opened, the flow rate will increase as the motor

cycle rate increases to keep up with the demand.

WARNING

Refer to general information sheet for additional

safety precautions and important information.

The Chop--Check pumps are primarily designed for the pumping of

heavy viscous material with or without fibrous content. The models

can be used with a gravity feed single post lift as a topper type as-

sembly or with a two post lift as a force feed type assembly. The low-

er pump is designed for easy priming and the double acting feature

is standard in all ARO industrial pumps. Material is delivered to the

pump discharge outlet on both the up and down stroke.

The motor is connected to the lower pump end by a spacer section.

This allows for lubrication of the upper packing gland and prevents

motor contamination because of normal wear and eventual leakage

through the material packing gland. Be sure the solvent cup is ade-

quately filled with lubricant to protect the upper packings and insure

longest service life.

TROUBLE SHOOTING

Pump problems can occur in either the Hydraulic Motor Section or the

Lower Pump End Section, use these basic guidelines to help determine

which section is affected.

If the pump will not cycle.

Be certain to first check for non--pump problems including kinked,

restrictiveorpluggedinlet/outlethoseordispensingdevice.Depres-

surize the pump system and clean out any obstructions in the inlet/

outlet material lines.

Refer to the motor manual for trouble shooting if the pump does not

cycle and/or hydraulic fluid leaks from the hydraulic motor.

If the pump cycles but does not deliver material.

Refer to the lower pump end manual for further trouble shooting.

PUMP CONNECTION -- UPPER / LOWER

NOTE: All threads are right hand.

1. Lay the pump assembly on a workbench.

2. Remove the top three screws and washers from the three spacer

rods (see figure 1).

3. Pull the hydraulic motor from the lower pump end until motor piston

rod is in the ‘‘down” position and lower pump end rod is in ‘‘up” posi-

tion.

4. Remove the three spacer rods by unscrewing the bottom three cap

screws and washers.

5. Remove the cotter pin and unscrew the lower pump end rod fromthe

adapter (see figure 2).

Pump Motor

Piston Rod

Cotter Pin

Y15--46--C

Adapter

93350--2

PUMP CONNECTOR DETAIL

FIGURE 2

REASSEMBLY

1. Align the pump motor with the lower pump end.

2. Screw the adapter onto the motor piston rod and secure with set

screw.

3. Screwthelowerpumprodintotheadapterandsecurewiththecotter

pin. NOTE: Bend the ends of the pin into the groove of adapter.

4. Reinstall the spacer rods to the lower pump end, securing with three

washers and cap screws.

5. Bring the motor and lower pump together and retain with the three

screws and washers.

PN 97999- 494

Reviews: