18
Wall Unit
Pipe and cable bundling
1. With the use of a band, wrap individually refrigerant piping with its insulation, the power cable,
and the drain hose. See diagram below.
2. When preparing the bundle, reserve a portion of the drain hose and of the power cable to
perform the installation. Reserve additional space to allow the drain hose to be separated from
the power connections and from the outdoor unit piping.
3. Tie these wrappings together to form a tube bundle. See diagram.
4. Liquid and gas tubes must be wrapped separately at the end.
5. Whenever possible, maintain a separation between the power cable and the communication
lines.
Suspensión de la unidad interior
1. Inserte el haz de tubos y cables dentro del casquillo de pared y dejar que pase hacia el
exterior.
2. Suspenda la unidad interior sobre el marco de montaje en la pared.
3. Con el uso de material sellador, rellene los huecos entre la tubería y el orificio de pared o
casquillo protector.
4. Asegure el haz de tubos con abrazaderas de montura.
5. Verifique que la unidad interior se encuentra fijada segura y correctamente en la pared.
indoor unit
gas
pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
drain hose band
connection pipe
indoor power cord
sleeve
upper hook
lower hook of
wall-mounting frame