User guide Link/2500 - Link/2500 I
Copyright© 2018 Ingenico
All rights reserved
17
4_5_4
Changing the battery (except Integration version)
It is imperative to use a battery authorized by Ingenico. There is danger
of explosion if battery used is not approved by Ingenico.
Turn it off by pressing simultaneously
and
(yellow key) for about
one second
Remove the battery trapdoor (see section 4.5.2“installing battery”)
Lift the
battery and remove it from its compartment
Carefully disconnect battery, following the instructions
below.
Extract the connector by pulling it slightly (arrow) to bring
it away from the terminal
housing.
Inform the terminal that battery will be
replaced (*). Do not start
the terminal or connecting terminal power supply
without battery.
Connect and install the new battery by
following the
instructions in section 4.5.2 “Installing
battery”
Close the battery trapdoor and charge the new battery. See section “Charging
the Battery»
In order to preserve the environment, dispose used battery in compliance with
current country recycling legislation.
(*)The terminal memorizes that there is no battery simply by powering up. It will then
correctly perform-full recharge with the next battery.
The battery disconnection must be exceptional. Battery
connector durability: up to 30 mating cycles