background image

MINIMUM 18" 

(45.7cm)

FROM SIDE

MINIMUM 18"

(45.7cm)

FROM SIDE

72" (1.8m) MINIMUM 

HEIGHT FROM FLOOR

5-3/4" (14.6cm)

LEVEL HERE

11/32" OUTSIDE NUT

11/32" INSIDE NUT 
(SNUG TO CERAMIC)

5

Disconnect power at the breaker. Remove two screws from one end of trim and slide trim off opposite end. Remove grill 
by grasping it in the middle, flex grill up and lift it off. Unscrew and remove both end reflectors. Unhook element clips 
at each end of the heater and remove nuts from end of element to remove the existing quartz tube. Carefully install the 
new element. Remove one nut from end of the new element. Install wire by sliding high temperature ring terminal onto 
element screw and replace nut. Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight connection. Close 
element clips over tube and reinstall end reflectors, and snap protective grill back in, then reinstall trim.

NOTE:  Hold ceramic element firmly while 

tightening nut to prevent damage to 
element. Nut should be tightened snug.  
A loose connection can cause the  
element to short or fail prematurely.

REPLACEMENT ELEMENT INSTALLATION 

(VISIT INFRATECH-USA.COM FOR VIDEO INSTRUCTIONS)

SCAN FOR 

VIDEO 

INSTRUCTIONS

Heater must be installed with the quartz tube horizontally level. For maximum tube life, use a level to find the optimum 
position for the heater’s body. Always maintain the minimum clearances from the heater body to any combustible 
materials.

REPLACEMENT ELEMENTS

 

PART NUMBER 

MODEL 

LENGTH 

WATTS 

VOLTS 

FITS

 

10-7025 

E-1612-SL 

22-3/8" (0.6m) 

1600 

120 

SL-1612

  10-7030 

E-1624-SL 

22-3/8" (0.6m) 

1600 

240 

SL-1624

  10-7035 

E-2424-SL 

35-3/8" (0.9m) 

2400 

240 

SL-2424

  10-7040 

E-2428-SL 

35-3/8" (0.9m) 

2400 

208 

SL-2428

  10-7055 

E-3024-SL 

56-3/8" (1.4m) 

3000 

240 

SL-3024

  10-7060 

E-3028-SL 

56-3/8" (1.4m) 

3000 

208 

SL-3028

  10-7075 

E-4024-SL 

56-3/8" (1.4m) 

4000 

240 

SL-4024

  10-7080 

E-4028-SL 

56-3/8" (1.4m) 

4000 

208 

SL-4028

Consult label on back of heater 

for proper watts, voltage, and  

replacement element part number.

Need help? 

To order replacement 

elements for your Infratech 

heating system, please contact  

us via phone or visit our website.

Summary of Contents for SL Series

Page 1: ...rnings 2 Installation Instructions 3 Wiring Instructions 3 Bracket Spacing 4 Mounting Instructions 4 5 Replacement Element Installation 5 Replacement Parts 5 6 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Page 2: ... 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is set at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL L...

Page 3: ... and rotate 180º Connect power with flexible conduit or appropriate cord to allow heater to be swiveled WIRING INSTRUCTIONS The heater is drilled and threaded for standard 1 2 conduit fittings The installing electrician will need to provide the appropriate rigid metallic flexible or liquid tight conduit for the installation location Use only copper wire suitable for 90 C Observe local electrical c...

Page 4: ...SPACING These models may be chain or bracket mounted to any ceiling or horizontal surface Installation must be such that 18 45 7cm minimum clearance is maintained around the heater on all four sides and 36 0 9m directly in front A minimum of 6 15 2cm of clearance provided by mounting brackets is required behind the plane of the face Adjustable wall ceiling brackets are furnished with all SL Series...

Page 5: ...t to prevent damage to element Nut should be tightened snug A loose connection can cause the element to short or fail prematurely REPLACEMENT ELEMENT INSTALLATION VISIT INFRATECH USA COM FOR VIDEO INSTRUCTIONS SCAN FOR VIDEO INSTRUCTIONS Heater must be installed with the quartz tube horizontally level For maximum tube life use a level to find the optimum position for the heater s body Always maint...

Page 6: ...se brackets may be discarded when the heater is hung with chains or other special bracketing See sales literature and price list for full listing of models descriptions amperages and voltages At times especially when the mounting height might be quite low an increased number of smaller heaters can help prevent overheating Heaters up to 15 AMPS can be controlled with a simple INF Input Regulator Th...

Page 7: ...TING Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed Angle fixture 30º to 60º from horizontal face down Best angle is approximately 45º Install fixture to heat the area from the cold si...

Page 8: ...es due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property however arising Important Please retain original proof of purchase to establish warranty period Any implied warranties of merchan...