![infra world TrioSol Natura 103 Instructions For Use Manual Download Page 23](http://html.mh-extra.com/html/infra-world/triosol-natura-103/triosol-natura-103_instructions-for-use-manual_2058337023.webp)
23
1.
Operating time:
The operating time of the heater corresponds to the operating time adjusted in the Infracontrol infrared control
system.
2.
Changing the power:
You can adjust the power of the VITALlight infrared heater from 0 - 100% by turning the knob.
Instructions for use of the Infracontrol infrared control system
Adjusting the infrared rotary button
GB
1.
Light:
The light can be switched on or off by pressing the button (the light can be switched on for cleaning
without starting the sauna).
2.
Switching the control on:
Press the button for 1 sec to switch on the light, the VITALlight infrared heater and the infrared heating
panels.
3.
Switching the control off:
Press the button for 1 sec.
4.
Operation:
After switching the control on, the remaining working time is displayed in minutes.
Change the remaining working time:
The current remaining time can be changed with the plus and minus buttons (in 5-minutes-steps).
Adjusting the basic settings:
1x button: The adjusted reference temperature flashes, the point next to the temperature symbol
lights up. The temperature can be adjusted in one-degree steps with the plus or minus buttons (20 - 80 °C or
20 to 60 °C). Hold the plus or minus button for 1 sec to start the fast mode.
2x button: Adjusted operating time flashes. This value can be changed with the plus or minus button.
The remaining time is updated to this value and the basic settings are stored (10 - 95 minutes).
3x button: Settings of the end, display of remaining working time.
After 4 seconds without pressing a button, the basic settings mode is closed automatically and the remaining
working time is displayed again.
5.
Changing the maximum temperature from 60 °C to 80 °C:
Hold the plus and minus button in the standby mode (when the display is dark) for 5 sec. The display shows
the current settings. By using the plus button, you can change between 60 °C and 80 °C.
The set value must be confirmed by pressing the button longer (1 sec.).
6.
Fault:
In case of sensor interruption or sensor defect, the controls switch off after 10 seconds.
The display is dark and the point next to the temperature symbol lights up. light, VITALlight infrared
heater and infrared heating panels are switched off.
Summary of Contents for TrioSol Natura 103
Page 4: ...Natura 103 4 ...
Page 6: ...Natura 120 6 ...
Page 8: ...Natura 148 8 ...
Page 10: ...10 Natura 103 ...
Page 11: ...11 Natura 120 ...
Page 12: ...12 Natura 148 ...
Page 13: ...4 x 4 x 35 6 x 4 x 70 6 x 4 x 70 6 x 4 x 70 6 x 4 x 70 1 2 3 4 13 ...
Page 14: ...6 x 4 x 70 1 2 16 x 3 5 x 40 1 2 10 x 4 x 50 1 2 12 x 4 x 35 3 3 x 3 2 x 25 5 6 7 8 14 ...
Page 17: ...1 2 9 4 x 3 5 x 40 8 x 4 x 70 4 x 4 x 50 10 11 17 2 x 4 x 50 920 mm 1096 mm 1370 mm 12 ...
Page 18: ...6 x 3 5 x 40 14 15 16 18 13 ...
Page 19: ...17 12 x 3 5 x 40 18 19 W R R R R 1 2 3 4 R W 19 20 ...
Page 20: ...Variante L 22 23 20 6 x 4 x 30 24 Variante R 21 ...
Page 21: ...25 21 ...