INFOSEC UPS SYSTEM - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec.fr
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - [email protected] - 07 05 04 205 04
79
20
Appendix 2- LED Display for E
4
5000/6000/10000
LED display
Alarm warning
N° Operating
state
1# 2# 3# 4# 5# 6# 7# 8# 9# 10#
1
0~35%
Load capacity
●
●
●
none
2
36%~55%
Load capacity
●
●
●
●
none
3
56%~75%
Load capacity
●
●
●
●
●
none
4
76%~95%
Load capacity
●
●
●
●
●
●
none
5
Utility
Power
Mode
96%~105%
Load capacity
●
●
●
●
●
●
●
none
6
0~20%
Battery capacity
●
●
●
Beep once every sec
7
21%~40%
Battery capacity
●
●
●
●
Beep once every 4 sec
8
41%~60%
Battery capacity
●
●
●
●
●
Beep once every 4 sec
9
61%~80%
Battery capacity
●
●
●
●
●
●
Beep once every 4 sec
10
Battery
Mode
81%~100%
Battery capacity
●
●
●
●
●
●
●
Beep once every 4 sec
11 Bypass
mode
↑
↑
↑
↑
●
●
●
Beep once every 2 min.
12
overloaded in utility mode and UPS still
in INV mode
●
●
●
●
●
●
●
●
Beep twice every sec.
13
overloaded in utility mode and UPS in
bypass mode
●
●
●
●
Continuously beep
14
Utility power abnormal
↑
↑
↑
↑
●
★
↑
↑
↑
↑
15
Overloaded in battery mode,
Early-warning
●
●
↑
↑
↑
↑
●
●
Beep twice every sec.
16
Overloaded in battery mode,
Cut off the output
●
●
Continuously beep
17 Over
temperature
●
●
↑
↑
Continuously
beep
18 Inv
abnormal
●
●
↑
↑
Continuously
beep
19
Output short circuited
●
●
●
↑
↑
Continuously
beep
20
BUS voltage abnormal
●
●
↑
↑
Continuously
beep
21
Charger or battery failed
●
●
●
↑
↑
★
Continuously
beep
22
Battery voltage abnormal
↑
↑
↑
↑
↑
●
●
★
↑
23
BAT SCR failed
●
●
●
Continuously
beep
24 Fan
abnormal
●
●
●
●
●
Continuously
beep
25
Bypass STS failed
●
●
●
●
●
Continuously
beep
26
INV RLY failed
●
●
●
●
●
Continuously
beep
27 Communication
abnormal
●
●
●
↑
↑
Continuously
beep
●
: Solid ON
★
: Flash
↑
: LED display and alarm warning are dependent on other conditions.