6 .   D E S C R I P T I O N  

 

 

A V R   -   F R O N T   P A N E L  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 – Power switch:

 ON/OFF switch: 

Always switch to ON mode during the use of the AVR 

Always switch to OFF mode during installation and maintenance. 

 

2 – Green LED:

 lighting when the AVR works properly 

 

3 – Red LED:

 lighting when the AVR is malfunction or under protection

 

 

4 – Yellow LED

: lighting or flashing when the AVR is in Delaying, by default the AVR is set 

for  6  seconds  delaying  to  take  inductive  or  capacitive  load  such  as  compressor  or  motor 

based equipments, select 180 seconds delaying time. 

 

5 – Input Voltage Meter

: by voltage meter or digital LED meter showing the input voltage. 

 

6  –  Output  Voltage  Meter

:  by  voltage  meter  or  digital  LED  meter  showing  the  output 

voltage 

 

7 – Delay/ undelay Selector

: Press to select the delay time of the AVR. 

Setting delay time as 3 minutes. It’s designed to avoid damage devices with AC motor from 

consecutive  starts.  It’s  perfect  to  use  with  devices  such  as  refrigerators,  freezers,  air 

conditioners or dehumidifiers.  

Setting delay time as 6 seconds. It’s designed for use with voltage sensitive equipment such 

as: personal computers, monitors, inkjet printers, scanners or faxes. It’s also designed for 

use with home appliances such as televisions, stereos, CD/DVD players, VCRs, modems, 

and telephone equipment. 

 

Summary of Contents for R2 Pro 10000VA

Page 1: ...User Guide________________________2 Notice d utilisation _________________9 From 1000 VA to 10 kVA AUTOMATIC VOLTAGE REGULATOR REGULATEUR DE TENSION AUTOMATIQUE...

Page 2: ...es to avoid damages to the appliances Microprocessor Control By means of innovative software control programs the complicated hardware circuitry is inlaid in the powerful microprocessor Apart from red...

Page 3: ...h the AVR to the Off position and disconnect the unit from the AC power supply When the AVR is out of order please refer to section 8 trouble shooting and call the hot line Connected products Make sur...

Page 4: ...e identification plate on the back of the unit If convenient you may enter the details in the following box Model Serial number Date of purchase R2 Pro Please keep the original packaging It will be re...

Page 5: ...ad such as compressor or motor based equipments select 180 seconds delaying time 5 Input Voltage Meter by voltage meter or digital LED meter showing the input voltage 6 Output Voltage Meter by voltage...

Page 6: ...t breaker for electric protection 4 Input terminal L Line N Neutral E Earth 5 Output terminal L Line N Neutral E Earth Audible Buzzer When protections like over input voltage under input voltage over...

Page 7: ...sary perform grounding of the casing of the AVR by connecting grounding wire to the corresponding terminal or at least make sure that the mains outlet is grounded and available with 3 pins connection...

Page 8: ...equency 50 or 60Hz Safety cycle 6seconds or 180seconds selectable Regulation Number of Taps 13 Transformer Type 13 Control Type Relay type Output connectors 2 x FR Schuko Terminal Indicator Working Gr...

Page 9: ...11 AC 2012 EN61000 6 1 2007 EN55022 2010 AC 2011 EN55024 2010 EN61000 3 2 2014 EN61000 3 3 2013 EN61000 3 11 2000 EN61000 3 12 2011 LVD EN61558 2 12 2011 EN61558 1 2005 A1 2009 Sales informations Warr...

Page 10: ...les quipements contre les variations brusques de tension Contr le par microprocesseur Grace son microprocesseur et firmware innovants le R2 Pro fournit une meilleure pr cision de r gulation de tension...

Page 11: ...ble d alimentation de la prise de courant afin de d sactiver compl tement le r gulateur Lorsque le r gulateur est en panne se r f rer la section 8 D pannage puis contactez le Service Apr s Vente Produ...

Page 12: ...areil Vous pouvez galement les reporter dans le cadre ci dessous Mod le Num ro de s rie Date d achat R2 Pro Veuillez conserver l emballage d origine il sera indispensable pour un ventuel retour de vot...

Page 13: ...d entr e cet afficheur indique la tension d entr e 6 Tension de sortie cet afficheur indique la tension de sortie 7 Bouton poussoir Delay Time presser pour s lectionner le Delay Time de l AVR 6 ou 18...

Page 14: ...alimentation 2 Prises sorties 3 Protection alimentation lectrique 4 Bornes d entr e L Phase N Neutre E Terre 5 Bornes de sortie L Phase N Neutre E Terre Alarme sonore si le R2 Pro d tecte une sous ten...

Page 15: ...surer que le R2 Pro soit reli la terre alimentation Ph N Terre 5 Pour mettre en marche le R2 Pro mettre l interrupteur sur position ON Pour l teindre mettre l interrupteur sur position OFF 6 Branchez...

Page 16: ...pour une tension d entr e de 72 Vac maximum Pr cision de lecture 8 D lai au red marrage 6 sec ou 180 sec s lectionnable Sortie 2 x FR Schuko Bornier R gulation Type de transformateur Toroidal Auto Tr...

Page 17: ...07 A1 2011 AC 2012 EN61000 6 1 2007 EN55022 210 AC 2011 EN55024 2010 EN61000 3 2 2014 EN61000 3 3 2013 EN61000 3 11 2000 EN61000 3 12 2011 LVD EN61558 2 12 2011 EN61558 1 2005 A1 2009 Informations com...

Reviews: