Condition
Possible Cause
Corrective Action
Forms are mishandled in the
folder or damaged during sealing.
Dirty fold rollers.
Clean rollers with
recommended cleaning
solution. See page 39 .
Fold roller adjusted
improperly or worn;
sealing rollers adjusted
improperly.
Contact your authorized
service representative for
advice.
Forms not sealing.
Pressure on sealing
rollers is relieved.
Reset pressure on the
sealing rollers. See page
32.
Forms have been
incorrectly stored, or are
older than their shelf life
(one year).
Use fresh forms.
Fold plate form stop(s)
adjusted improperly
causing poor registration
of adhesive strips.
Check and adjust
position of the fold plate
form stop(s). See page
16.
Sealing rollers adjusted
improperly.
Contact your authorized
service representative for
advice.
Forms are misfeeding.
In-feed tray form guides
are set too tight or too
loose.
Set the guides so there is
just enough clearance to
allow the form to move
freely between the
guides.
Fold plates not installed
properly.
Install fold plates
properly.
Worn feed roller.
Contact your authorized
service representative for
advice.