Infortrend Expansion Guide

 

 
 

Copyright ©  2019 Infortrend Technology, Inc. All rights reserved.

 

Page 11 / 15 

3. Reconnecting the redundant SAS path   
(for redundant models only) 

Unplug the SAS cable from the current last expansion controller (see dotted

 orange

 connection in 

Figure 9

), then connect it 

to the SAS port of newly-added last expansion's second controller (see longest 

orange

 cable connection in 

Figure 9

). A longer 

SAS cable may be required. 

This  step  involves  disconnecting  one  of  the  SAS  cables,  so  critical  events  on  storage  system  such  as  reports  of  drive-side 

redundant path failure are expected. You will get notification events from the management GUI, LCD panel, LEDs, and other 

means of notification alerts. 

 

Figure 14: Redundant path failure of expansion enclosures in SANWatch 

4. Connecting new SAS cable   

Connect  new  SAS  cables  (see 

black 

connection)  from  the  current  last  expansion  to  the  newly-added  expansion  enclosure. 

Ensure to follow the SAS connection's

 IN to OUT

 rule described in 

Expansion Enclosure Connections

. 

NOTE: 

The sample diagram is only for SAS 12 Gb/s storage system.

 

   

5. Turning on the newly-added expansion enclosure 

Press  the  power  button  to  turn  on  the  expansion  enclosure,  then  wait  for  the  storage  management  GUI  to  display  the 

additional  expansion  enclosure.  Once  the  added  subsystem  is  successfully  working  with  the  system  assembly,  the  storage 

system's status on the management, GUI, LCD panel, LED panel, and other status features are back to normal. 

Do take note that adding a newly-added expansion enclosure also sets the Hot-Add feature, which may cause delay or pause 

for about 10-20 seconds on the host I/O. The delay/pause  time may vary depending on the operating system, drivers, and 

other factors. 

 

 

Summary of Contents for EonServ 4012

Page 1: ...ted April 2019 Abstract This guide contains instructions and system limitations for adding expansion enclosures to Infortrend storage system without affecting its existing storage operations Expansion...

Page 2: ...del Classification Single and Redundant 9 Expansion Enclosure On line Expanding 10 1 Setting the expansion enclosure ID 10 2 Installing the newly added expansion enclosure 10 3 Reconnecting the redund...

Page 3: ...onStor GSc 2000 3000 448 within 15 mixed expansion enclosures 448 within 15 mixed expansion enclosures 896 448 448 EonStor GS 5000 EonStor GSc 5000 N A N A 896 within 15 mixed expansion enclosures x 2...

Page 4: ...rview of Maximum Drives Systems that support hybrid expansion enclosures EonStor DS GS GSe family 12 Gb s SAS drive side models EonStor GSc family EonStor GSe Pro 3000 series Systems that do not suppo...

Page 5: ...d Expansion Enclosures Figure 3 Hybrid Expansion Enclosures of EonStor GS GSc 5000 Expansion Board 896 Drives within 15 Expansion Enclosures 896 Drives within 15 Expansion Enclosures On board SAS Expa...

Page 6: ...stem Onboard Expansion Port For any type of expansion enclosure connect a SAS cable blue from the primary controller s SAS expansion port of the storage system to the primary controller s OUT SAS port...

Page 7: ...Infortrend Technology Inc All rights reserved Page 7 15 Figure 7 Connecting single controller expansions using the onboard SAS 12Gb s expansion ports Figure 8 Connecting dual controller expansions usi...

Page 8: ...cond controller s SAS expansion port of the storage system to the second controller s IN SAS port of the last expansion enclosure Basic connection rule when connecting systems in this connection type...

Page 9: ...n refer to the table below High Availability Models Single Model Redundant Model Upgradable EonStor DS 1000 2000 G Model R Model No EonStor DS 3000 DS 3024 3024B S Model R Model Yes DS 3012 3016 G Mod...

Page 10: ...13 Expansion enclosure ID 2 Installing the newly added expansion enclosure Due to the expansion enclosure s heavy weight we recommend you to install the hard drives to the expansion enclosure after th...

Page 11: ...sures in SANWatch 4 Connecting new SAS cable Connect new SAS cables see black connection from the current last expansion to the newly added expansion enclosure Ensure to follow the SAS connection s IN...

Page 12: ...s status in the storage management GUI Once the drives appeared on the GUI you can already use them in storage provisioning For more details refer to the software manual IMPORTANT If SANWatch or Embed...

Page 13: ...6Gb s DS3024 SAS 6Gb s 14 x JB 2016 JB 3016 5 x JB 2048 5 x JB 2060 L JB 3060 L DS1024B SAS 6Gb s DS2024B SAS 6Gb s DS3024B SAS 6Gb s 14 x JB 2024B JB 3024B 5 x JB 2048 5 x JB 2060 L JB 3060 L DS1036...

Page 14: ...S16E R2152 6 S16S R2250 8 x ESDS S16S J2000 R JB 2016R 3U 6 x ESDS B24S J2000 R 2U 4 x ESDS S48S J2000 R 4U 5 x ESDS S16S J2000 R JB 2016R 3 x ESDS S48S J2000 R 2 x ESDS S16S J2000 R JB 2016R 4 x ESDS...

Page 15: ...E R2142 6 B24S R2242 4 B24S R2240 5 x ESDS B24S J2000 R 2U 5 x ESDS S12S J2000 R JB 2012R 2U 5 x ESDS S16S J2000 R JB 2016R S12F S2840N 6 x ESDS S12S J2000 SN 2U S12F R2840N 6 x ESDS S12S J2000 RN 2U...

Reviews: