 INF561-Y01-U105-1-00 

3

 

Installation 

Check  if  the  Infocharger  has  been  subjected  to  any damage  before  unpacking  it.  If  you  notice  any 
damage, please contact to transport firm. Check if all the additional parts have been supplied with the 

battery charger. 

Please make sure that the packing contains the following 

 

  Infocharger 

 

  User Manual 

 

  Test Report 

Before  the  installation,  please  check  if  your  Infocharger  is  customized  following  your  special 
requirements (if any). 

In standard battery charger the output voltage and frequency can be adjustable between 0-30Vs and 
60-135Vs

 

 

3rd1

 

Handling 

If needed to move the battery charger, it is obligatory to pack the unit. It is suggested to keep the 
original packing.  

3rd2

 

 Storage 

Please store the battery charger in an environment where the temperature is between –15 

°

C and +55 

°

C no 

receipt of direct sunlight, far from the heating, in a dry place. Environmental humidity must be between %20 
and %95 (non-condensing). 

 

3rd3

 

Positioning 

Infocharger and battery cabinet(if any) have to be positioned in an environment; 

 

No direct sun access, 

 

Must be dry, 

 

Far from the heating equipments  

 

No excessive dust 

 

Well-ventilated 

 

In  order  to  maintain  adequate  ventilation  of  Infocharger  and  battery  cabinets  (if 
any), ensure the air vents are not blocked and leave at least 20 cm space at the rear 
side of the unit for ventilation. 

Summary of Contents for Infocharger

Page 1: ...Infocharger DC POWER SUPPLY BATTERY CHARGER...

Page 2: ...tions For the staff and equipment safety it is necessary for the users to fully read and save this manual before working on this equipment Description of the Symbols IMPORTANT NOTICE Please follow the...

Page 3: ...connection 5 4 Switch On and Switch OFF procedures 6 4th1 System Switch ON 6 4th2 System Switch OFF 6 5 Operating Instructions 7 5th1 Unit Operation 7 5th1 1 Operation modes 7 5th2 Displays 8 5th2 1...

Page 4: ......

Page 5: ...missioning have to be done by authorized technical service Earth Ground connection should be done Do not plug in off the communication interface cables during bad weather conditions with lightning To...

Page 6: ...ing on the battery type These are initial charge float charge boost charge and temperature or auto controlled charging types The charge voltages per cell for initial charge 2 04V for float charge 2 23...

Page 7: ...Battery Charger features and benefits Feature Benefit PWM technology Transformerless design Compact design small dimensions and low weight Microprocessor controller To use all the sources in optimum...

Page 8: ...3rd1 Handling If needed to move the battery charger it is obligatory to pack the unit It is suggested to keep the original packing 3rd2 Storage Please store the battery charger in an environment wher...

Page 9: ...onnection between the grounding unit of the Infocharger and the ground can be made according to the minimum cross sectioned cables which are given in the technical specifications table below 3rd4 2 In...

Page 10: ...he automatic fuses on the front panel if mains voltage is within the limits the unit switches on Inforcharger makes self test for few seconds to check if everything is normal and then starts to charge...

Page 11: ...25 30 35 1 6 11 16 21 26 31 36 41 46 51 TIME CURRENT VOLTAGE 0 0 5 1 1 5 2 2 5 Ibat Vbat Cell Battery current is controlled in a way to keep stable the power transferred to batteries in direct charge...

Page 12: ...our display sections on the control panel as follows On the Operation mode section of the display the actual operating mode is seen On the left part of this display section the following messages can...

Page 13: ...the output voltage is adjustable between values 0 30 0 60 0 140 VDC Iout It is adjustable between 0 255 the current is adjustable between values 0 60 0 30 0 15 A according to the type of Infocharger I...

Page 14: ...ress between 0 8 Ver Seri no Serial number 5th2 1 2 Buttons There are mainly four buttons in the front panel The functionalities of the buttons are given below button Scroll down to next line button S...

Page 15: ...n be chosen on the control panel This voltage level can not be less than 1 65V which is the minimum voltage level per cell 2 Delay module This module is designed for the automation processes and has 8...

Page 16: ...n the unit than you should perform the following Disconnect the loads Bring all the fuses on the unit to 0 position Clean the unit with a slightly moistened cloth Do not drop any liquid and solid fore...

Page 17: ...se check input fuses If you can read the battery and load voltage on front panel but can not measure the same voltage at battery and load then check the battery and load fuses If there is an over temp...

Page 18: ...running 90 280 V Input frequency range at mains running 45 Hz 65 Hz Power factor at nominal input voltage 0 99 Current Total Harmonic Distortion THD 3 Efficiency 90 Output Output voltage 24VDC 48VDC...

Page 19: ...e range at mains running 176 265 V Input frequency range at mains running 45 Hz 65 Hz Power factor at nominal input voltage 0 8 Efficiency 90 OUTPUT Output voltage 24VDC 48VDC 110VDC 220VDC Initial ch...

Page 20: ...Cable cross section area mm2 Current value absorbed by t he load Amp 1 5 18 4 34 6 44 10 61 16 82 25 108 35 135 50 168 70 207 95 250 120 292 150 335 185 382 240 453 300 504 THESE UNITS ARE GIVEN FOR...

Page 21: ...I TAFICS RCU ddb BLOCK DIAGRAM 1 1 CHARGE RECTIFIER INF561 Y18 S101 1 00 MAIN CONTROL BOARD DISPLAY DRIVER SUP CONTROL RELAY X4 X403 X404 FAN X101 X101 X401 X403 X101 X102 X103 X205 X206 L L X1 X2 X3...

Reviews: