Inconsistent or Unexpected Test Results

If you continue to get unexpected results, check your system with control solution. If you 
experience symptoms that are not consistent with your glucose results, review and follow all 
the instructions in this manual. Do not ignore symptoms or make significant changes to your 
diabetes control program by informing healthcare professional of your symptoms and/or 
concerns.

CAUTION

1. Low Glucose Results: If your result is lower than 70mg/dL, you may have episodes 

of hypoglycemia (low blood sugar). This may require immediate treatment, according 
to your healthcare professional’s recommendations. Although this result could be 
due to a test error, it is safer to treat first and you may test another.

2. High Glucose Results: if your test result is higher than 180 mg/dL, you may have 

episodes of hyperglycemia (high blood sugar). If you are uncertain about your test 
results, consider re-testing. Your health care professional will help you to decide how 
you need to act. If the meter displays “HI” all the time, please re-check your blood 
sugar. If the “HI” continues, please consult with your healthcare professional 
immediately.

Warranty

Manufacturer’s Warranty

Infopia Co.,Ltd. warrants to the original purchaser that this instrument will be free from 
defects in workmanship for 3 years from the date of original purchase.

Limitations of Warranty

This warranty is subject to the following exceptions and limitations.
1. Infopia Co.,Ltd. shall not be required to replace any units which are damaged or 

malfunctioning due to abuse, accidents, alteration, neglect, misuse, maintenance by 
someone other than Infopia Co.,Ltd. or failure to operate, in accordance with the 
instructions.

2. Infopia Co.,Ltd. reserves the right to make changes in design without obligation to 

incorporate such changes into previously manufactured instruments.

3. Infopia Co.,Ltd. has no knowledge of the performance of the instrument when the test 

strip is altered or modified in any manner.

For Warranty Service

Purchaser must contact the customer service department of Infopia Co.,Ltd. by calling 
+82-31-460-0300, for assistance and/or instructions for obtaining service of this instrument. 
Alternatively, you are requested to contact your place of purchase in your country for initial 
warranty request.

Service Information

Infopia Co.,Ltd. has trained specialists to help you 24 hours a day, 7 days a week, and 365 
days a year.

IMPORTANT NOTICE

Please confirm with the Infopia Co.,Ltd. representative before returning your meter for any 
reason. You will be given the information needed to get your problem handled correctly and 
efficiently. Keep your meter, test strip and control solution with you, when you call.

Summary of Contents for GluNEO Lite

Page 1: ......

Page 2: ...Blood Glucose Monitoring System for self testing...

Page 3: ...ional before making any changes to your diabetes management The GluNEO Lite Blood Glucose Monitoring System is for in vitro diagnostic use only Important Information The GluNEO Lite Blood Glucose Moni...

Page 4: ...based on the GluNEO Lite meter test results without contacting your physician or healthcare professional first 6 Do not assemble or disassemble the blood glucose test meter 7 Keep out of direct sunli...

Page 5: ...ith GluNEO Lite test strips Do not use during or soon after xylose absorption testing Xylose in the blood will cause interference Before using any product please read all instructions Consult with you...

Page 6: ...Result System Before Having a Meal After Having a Meal After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test User ID Symbol Test Strip Code Symbol Test Result...

Page 7: ...ps in new vials or in any other container 3 Immediately replace the vial cap and close tightly after removing any test strips from the vial 4 Make a note of the expiry date which is six months from th...

Page 8: ...essing and releasing either or buttons to turn the User ID option on off push button Temperature Unit After pressing and releasing either or buttons to set or and push button Alarm time After pressing...

Page 9: ...e able to check that the meter and test strips are working properly and that you are performing the test correctly It is very important that you perform routine checking to ensure accurate results The...

Page 10: ...r animal consumption 6 The control solution bottle icon contains letter C so as not to be confused with the medication bottle This will allow you to understand differences between a control solution t...

Page 11: ...device it provides ultimate safety and comfort for obtaining blood samples An adjustable tip offers 5 different strength levels of skin penetration for individual user s comfort while a lancet ejecto...

Page 12: ...stem Sliding Barrel Release Button Performing a blood test with your fingertip CAUTION 1 If you do not see the code displayed pull the glucose test strip out of the port and re start the procedure fro...

Page 13: ...wist the protective cover off Do not discard To obtain a suitable blood samples Before obtaining a blood sample wash your hands with warm clean water and soap Dry hands completely before testing Step...

Page 14: ...your meter by contaminating it Correct Completely Filled Incorrect Poorly filled Applying Blood Step 4 If you selected to use the User ID option during set up press and button to select the correct U...

Page 15: ...ucose test meter 3 Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities Reviewing Your Results The GluNEO Lite meter stores up to 365 test resu...

Page 16: ...different areas of your body The figure shown above displays the areas where you can test using your GluNEO Lite meter You may test your blood sugar from your forearm upper arm palm ventral palm or do...

Page 17: ...cemia unawareness To ensure accurate results when lancing your arm forearm or upper arm or palm ventral palm or dorsal hand clean the test site with soap and water Make sure there is no cream or lotio...

Page 18: ...lood glucose test meter Your GluNEO Lite blood glucose test meter is a precision instrument Please handle it with care Lancing device Clean the lancing device and tips with soap and tepid water To dis...

Page 19: ...perature After use close cap tightly Make sure the control solution bottle is tightly closed Record the discard date date vial opened plus 3 months on the control solution on the bottle Do not use if...

Page 20: ...hcare professional NOTE 1 Make sure your date and time are correct after changing your battery 2 Please recycle or dispose of used batteries using your local battery collection systems and in complian...

Page 21: ...movetheBloodglucosetest strip from the GluNEO Lite Blood glucose test meter Dispose of used Blood glucose test strip in a sealed container with your household waste in accordance with local regulation...

Page 22: ...ommenda tions Perform a control solution test to check the accuracy of your test strip Message What it means Action required Trouble shooting Test result is higher than 600 mg dL 33 3mmol L Check the...

Page 23: ...t this instrument will be free from defects in workmanship for 3 years from the date of original purchase Limitations of Warranty This warranty is subject to the following exceptions and limitations 1...

Page 24: ...not Freeze Display Type LCD Reading Time 5 seconds Sample Type Capillary and or venous whole blood Symbol Reference Consult Instructions for use Use By date This product fulfills the requirements of D...

Page 25: ...Memo Memo...

Page 26: ...Memo...

Reviews: