Deleting Test Results

Reviewing your results with activated user ID

Deleting individual test result

To delete any individual test result in the memory, press 

 or 

 button for 3 seconds. Then displayed          icon 

will start blinking.

Press the        button once and the User ID option will 
appear the LCD screen.
Use 

 or 

 buttons to scroll and choose the correct 

user ID, then press the        button.

If you choose the User ID to check the stored results, 
only the results of the selected user ID are displayed.

Deleting all the test results

To delete all test results in the memory press 

 and 

 

button for 3 seconds. Then displayed          ,          will 
start blinking.

CAUTION

Deleted test results cannot be recovered. Please be careful in deleting the test results.

DATE

GluNEO

®

 Lite blood glucose monitoring system gives you the ability to your sugar from 

different areas of your body. 
The figure shown above displays the areas where you can test using your  GluNEO

®

 Lite 

meter.You may test your blood sugar from your forearm, upper arm, palm (ventral palm
or dorsal hand), or fingertips.

Lancing and sampling from an alternative site area

Sampling from your upper arm, forearm, ventral palm, or dorsal hand allows you to use your 
fingertips less often.
You may find that obtaining a blood sample from an alternative site is less painful than using 
a fingertip.

LIMITATION

1. Alternative site testing results should never be used to calibrate continuous glucose 

monitoring systems.

2. Alternative sampling results should never be used in insulin dosing calculations.

IMPORTANT

It is recommended that alternative site testing be used when sugars are stable: before 
meals and before bedtime. However, when sugars are changing, blood from the fingertip 
may show these changes sooner than blood from other body areas. 

Upper Arm

Forearm

Ventral Palm

Dorsal Hand

Fingertips

Alternative Site Test

Summary of Contents for GluNEO Lite

Page 1: ......

Page 2: ...Blood Glucose Monitoring System for self testing...

Page 3: ...ional before making any changes to your diabetes management The GluNEO Lite Blood Glucose Monitoring System is for in vitro diagnostic use only Important Information The GluNEO Lite Blood Glucose Moni...

Page 4: ...based on the GluNEO Lite meter test results without contacting your physician or healthcare professional first 6 Do not assemble or disassemble the blood glucose test meter 7 Keep out of direct sunli...

Page 5: ...ith GluNEO Lite test strips Do not use during or soon after xylose absorption testing Xylose in the blood will cause interference Before using any product please read all instructions Consult with you...

Page 6: ...Result System Before Having a Meal After Having a Meal After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test User ID Symbol Test Strip Code Symbol Test Result...

Page 7: ...ps in new vials or in any other container 3 Immediately replace the vial cap and close tightly after removing any test strips from the vial 4 Make a note of the expiry date which is six months from th...

Page 8: ...essing and releasing either or buttons to turn the User ID option on off push button Temperature Unit After pressing and releasing either or buttons to set or and push button Alarm time After pressing...

Page 9: ...e able to check that the meter and test strips are working properly and that you are performing the test correctly It is very important that you perform routine checking to ensure accurate results The...

Page 10: ...r animal consumption 6 The control solution bottle icon contains letter C so as not to be confused with the medication bottle This will allow you to understand differences between a control solution t...

Page 11: ...device it provides ultimate safety and comfort for obtaining blood samples An adjustable tip offers 5 different strength levels of skin penetration for individual user s comfort while a lancet ejecto...

Page 12: ...stem Sliding Barrel Release Button Performing a blood test with your fingertip CAUTION 1 If you do not see the code displayed pull the glucose test strip out of the port and re start the procedure fro...

Page 13: ...wist the protective cover off Do not discard To obtain a suitable blood samples Before obtaining a blood sample wash your hands with warm clean water and soap Dry hands completely before testing Step...

Page 14: ...your meter by contaminating it Correct Completely Filled Incorrect Poorly filled Applying Blood Step 4 If you selected to use the User ID option during set up press and button to select the correct U...

Page 15: ...ucose test meter 3 Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities Reviewing Your Results The GluNEO Lite meter stores up to 365 test resu...

Page 16: ...different areas of your body The figure shown above displays the areas where you can test using your GluNEO Lite meter You may test your blood sugar from your forearm upper arm palm ventral palm or do...

Page 17: ...cemia unawareness To ensure accurate results when lancing your arm forearm or upper arm or palm ventral palm or dorsal hand clean the test site with soap and water Make sure there is no cream or lotio...

Page 18: ...lood glucose test meter Your GluNEO Lite blood glucose test meter is a precision instrument Please handle it with care Lancing device Clean the lancing device and tips with soap and tepid water To dis...

Page 19: ...perature After use close cap tightly Make sure the control solution bottle is tightly closed Record the discard date date vial opened plus 3 months on the control solution on the bottle Do not use if...

Page 20: ...hcare professional NOTE 1 Make sure your date and time are correct after changing your battery 2 Please recycle or dispose of used batteries using your local battery collection systems and in complian...

Page 21: ...movetheBloodglucosetest strip from the GluNEO Lite Blood glucose test meter Dispose of used Blood glucose test strip in a sealed container with your household waste in accordance with local regulation...

Page 22: ...ommenda tions Perform a control solution test to check the accuracy of your test strip Message What it means Action required Trouble shooting Test result is higher than 600 mg dL 33 3mmol L Check the...

Page 23: ...t this instrument will be free from defects in workmanship for 3 years from the date of original purchase Limitations of Warranty This warranty is subject to the following exceptions and limitations 1...

Page 24: ...not Freeze Display Type LCD Reading Time 5 seconds Sample Type Capillary and or venous whole blood Symbol Reference Consult Instructions for use Use By date This product fulfills the requirements of D...

Page 25: ...Memo Memo...

Page 26: ...Memo...

Reviews: