Performing Your Test

Testing Blood - Preparation

Lancing device is a convenient medical tool for collecting capillary blood samples for 
glucose monitoring or other tests which require one or two drops of blood. 
Being a more advanced lancing device, it provides ultimate safety and comfort for obtaining 
blood samples. An adjustable tip offers 5 different strength levels of skin penetration for 
individual user’s comfort, while a lancet ejector enables the safe disposal of the used lancet. 
As an added bonus, this also comes with a transparent tip for AST (Alternative Site Testing).

CAUTION

1. Never use a lancet that has been used by someone else. This could lead to contami-

nation.

2. If the lancing device is to be used by another person, the unit must use a new tip or 

properly disinfected

3. Do not leave the lancet in the device after use.
4. A new lancet must only be placed into the lancing device directly before testing.
5. This device has many small parts and could be a choking hazard for children if 

swallowed.

6. In the case of hospital use, hospitals need to observe their own infection control 

protocols in order to avoid any contamination.

7. Always dispose of the used lancet in a biohazard garbage container.

• 21 •

Depth Indicator/Adjustable Tip

Lancet Holder

Clear Tip

Ejection System

Sliding Barrel

Release Button

ɋ

ɍ

Ɍ

Ɍ

Ɍ

ƣ

COMPONENTS

RECOMMENDED AVAILABLE LANCETS

Some general sterilized lancets are  infolet, ELEMENT, Lanzo, Gleenlan BD-Ultra Fine, 
Cleanlet Fine, E-Z Ject,
G-P Lite, Microlet, Monolet, One Touch, Soft Touch, Therasense, Ultra TLC and Unilet GP.
Note: Some less known lancets may not work properly with the due to their dimensions.
Please, contact your supplier to make sure you are using proper lancets

USING THE CLEAR TIP (AST)

1. Place the lancing device and lancet on the skin in the chosen area, press and hold it 

continuously for a few seconds, then push the release button to take a blood sample.

2. Watch through the clear tip until a sufficient blood sample is taken. If there is not enough 

blood, gently massage the area until a sufficient sample is collected.

 

STORAGE  

Products must be stored at room temperature protected from sunlight or moisture.

 

CLEANING AND DISINFECTION

-Clean and wipe the outer part of lancing device once a week at the minimum with a soft 
cloth dampened with mild soap and water. Wash the adjustable tip and clear tip, once a 
week with mild soap. 
-DO NOT immerse the lancing device in water or liquid.
 

WARRANTY

Lancing device has a 2-year warranty from the date of purchase.
A malfunctioning device should be returned to the following address:
address:

Summary of Contents for Element Neo

Page 1: ......

Page 2: ...rofessional before making any changes to your diabetes management The Element NEO Blood Glucose Monitoring System is for in vitro diagnostic use only Important Information The Element NEO Blood Glucos...

Page 3: ...st meter 3 Element NEO kit contents 7 Element NEO meter 8 Element NEO meter Display 9 Element NEO test strip 10 2 Before Testing Setting your meter 12 Auto coding function 14 LED function 15 Performin...

Page 4: ...ructions Consult with your physician or diabetic healthcare professional about daily manage ment of your diabetes and proper use of the glucometer If you have any questions about the Element NEO produ...

Page 5: ...clothes carpets etc may cause damaging static discharge in a dry environment 2 Do not use Element NEO glucose test meter near cellular or cordless telephones walkie talkies garage door openers radio t...

Page 6: ...ve 40 104 F 8 Do not test in the condition that humidity is below 10 or above 90 9 Do not bend cut or alter the test strip 10 Avoid getting dirt food and water on the test strip with wet hands 11 Avoi...

Page 7: ...s to set the number of days for average calculation 3 different settings possible push button Alarm on off After pressing and releasing either or buttons to turn the alarm on off push button Temperatu...

Page 8: ...ase check the code number on the LCD window together with the code number on the glucose test strip vial to see if code numbers match each other Blood Glucose Test Strips INFS001B Discard date I 17 os...

Page 9: ...cordingly Press and release either the or button then Control Solution bottle icon will appear Then press 17 1 Check the expiration date before performing a control solution test Do not use if expired...

Page 10: ...erform the more accurate glucose control solution test you can use the control solution 3 different levels low normal and high You can buy each Element NEO control solution low normal and high levels...

Page 11: ...biohazard garbage container 21 Depth Indicator Adjustable Tip Lancet Holder Clear Tip Ejection System Sliding Barrel Release Button COMPONENTS RECOMMENDED AVAILABLE LANCETS Some general sterilized la...

Page 12: ...and temperature Make sure the code number matches on the test strip bottle e g 17 Element NEO automatically recognizes the test strip code number and adjusts the meter accordingly A blinking test stri...

Page 13: ...glucose test strip Discard the glucose test strip and re start testing 2 If you do not conduct the test within 3 minutes the glucose test meter will automatically power off to save battery life In thi...

Page 14: ...regulation After the beeping sound test will begin automatically and your results will appear in 5 seconds It should begin counting down from 5 to 1 second on the LCD display window LCD window will d...

Page 15: ...activated user ID Deleting individual test result To delete any individual test result in the memory press or button for 3 seconds Then displayed icon will start blinking After the third beep sound y...

Page 16: ...glucose monitoring systems 2 Alternative sampling results should never be used in insulin dosing calculations IMPORTANT It is recommended that alternative site testing be used when glucoses are stabl...

Page 17: ...l seconds 6 While holding the lancing device on your test site look through the clear tip until a round drop of blood appears 7 Lift the lancing device straight up be careful not to smear the blood on...

Page 18: ...blood glucose test strips in water or liquid 4 Do not subject the meter or blood glucose test strips to excessive heat 5 Use your meter according to the instructions in the manual 6 If you need to pur...

Page 19: ...expiration date printed on the package or vial since it may cause inaccurate results 6 Do not test at temperatures below 10 50 F or above 40 104 F 7 Do not test with humidity below 10 or above 90 8 Do...

Page 20: ...and Electronic Equipment WEEE regulation implement provisions of the European Parliament and Council Directive 2012 19 EU aimed to reducing the amount of EEE waste going for final disposal The manufa...

Page 21: ...ion required 41 Trouble shooting User applied the blood sample before the LCD display was blinking Wait for the meter to display the blinking icon before applying your blood sample Caused by color bar...

Page 22: ...erform your test again Please insert a new test strip and perform your test again There are no reading stored in the meter Not enough reading in the memory to display designated average The glucose te...

Page 23: ...460 0300 for assistance and or instructions for obtaining service of this instrument Alternatively you are requested to contact your place of purchase in your country for initial warranty request Ser...

Page 24: ...See Instructions for use For In Vitro Diagnostic Use Batch code Do not reuse Serial number Date of Manufacture Manufacturer Keep away from sunlight Waste electrical and electronic equipment Symbol Tem...

Page 25: ......

Reviews: