Open an Internet browser window and enter 

 

 

 

 

 

 

 

.

https://<IP address or hostname of the NIOS appliance>

Accept the certificate when prompted. 
A certificate warning appears during the login process. This is normal because the appliance generates a self-signed certificate when it
first starts, and your browser does not have a trusted CA certificate or a cached appliance server certificate (saved from an earlier
connection) to authenticate the appliance certificate. Also, the hostname in the default certificate is www.infoblox.com, which is unlikely to
match the hostname of your appliance. Messages appear warning that the certificate is not from a trusted certifying authority and that the
hostname on the certificate is either invalid or does not match the name of the site that sent the certificate. Either accept the certificate
just for this session or save it to the certificate store of your browser.

Note: To eliminate the certificate warning, generate a new self-signed certificate or import a third-party certificate with a common name that
matches the FQDN (fully-qualified domain name) of the appliance. The process is straightforward. For information about certificates, refer to the N

 

.

IOS Administrator Guide

3. Log in using the default user name and password 

 and 

.

admin

infoblox

Note: User names and passwords are case-sensitive.

4. Read the Infoblox End-User License Agreement and click 

 to proceed. The Setup Wizard opens for defining basic network and

I Accept

deployment settings.

Determine how you want to deploy the appliance, and use the following worksheets to note the network settings that you want to enter on the
wizard screens. If you are configuring an HA pair, you individually configure each node.

Settings

Enter your information here                                                     
                                                              

Grid Name

Shared Secret Host Name

Grid Master's IP Address

LAN1 Port IP Address and Netmask

Gateway IP Address

*Port Settings

**Admin Password

**Local Date, Time, and Time Zone

- or -

NTP Server IP Address

* For Grid master and member

** For an independent appliance or Grid master
Use the following worksheet when configuring an independent HA pair or an HA Grid master:

Settings

Enter your information here   

Grid Name 
*Shared Secret

Host Name

Virtual Router ID

VIP (Virtual IP) Address and Netmask

Node 1: HA Port IP Address

Node 2: HA Port IP Address

Node 1: LAN1 IP Address

Node 2: LAN1 IP Address

Gateway IP Address

Summary of Contents for IB-4010

Page 1: ...Infoblox Installation Guide 4000 Series Appliances Infoblox IB 4010 and Infoblox IB 4020 Advanced Appliance PT 4000 Network Insight ND 4000 Trinzic Reporting TR 4000 ...

Page 2: ...es Rack Installation 13 2 3 Powering On the Infoblox 4000 Series Appliance 15 2 4 Cabling the Appliance to a Network 15 3 Accessing the Infoblox 4000 Series Appliance 16 3 1 Connecting to the Appliance 17 3 2 Auto Provisioning NIOS Appliances 18 3 3 Specifying Appliance Settings 18 3 4 Infoblox NIOS CLI 20 4 Infoblox 4000 Series Field Replaceable Units 20 4 1 Managing the Infoblox 4000 Series Disk...

Page 3: ...in either capacity with a second IB 4010 appliance in high availability HA mode You configure and manage the IB 4010 appliance through the Grid Manager Note The IB 4010 appliance is currently sold in a Rev 2 hardware platform Infoblox supports a previous platform version Rev 1 only with field replaceable units FRUs and warranty replacements Current Rev 2 platform FRUs such as power supplies and fa...

Page 4: ... Hot swappable AC or DC power supplies in a redundant 1 1 configuration Alternative system configurations for the support of copper or fiber SFP 10GbE interfaces with support for mixed copper fiber deployments and mixed 1GbE and 10GbE deployment based on installed transceivers Network Insight ND 4000 Product Overview The Network Insight ND 4000 is a high performance network appliance that supports...

Page 5: ...f you wish to run the Infoblox 4000 Series in a NEBS 3 configuration remove the front panel of the appliance as shown in for DC Figure 2 only Figure 1 Infoblox 4000 Series Front View Appliance Front Panel Removing the front panel cover reveals front panel components including the hard disk drives and indicator lights illustrated in and Figure 2 described in For explanations of Ethernet port LEDs a...

Page 6: ... that goes around the Fault UID LED to indicate read write activity status of the disk drive VGA Port The VGA port is not supported Use the console port or LAN1 port for initial setup Disk Drive Front Panel LEDs Disk drives are located on the appliance front panel To the right of each drive two LEDs display connection and activity status lists the Table 2 disk drive LED combinations and the states...

Page 7: ...nsceivers in the LAN1 and LAN2 ports for an Infoblox 4010 appliance and installing 1GbE SFP copper transceivers in the MGMT and HA interfaces Note For ND 4000 and TR 4000 appliance models configured with 1GbE SFP or 10GbE SFP interfaces the HA port is reserved for future use and otherwise unused Order of ports from left to right is otherwise identical See the section for specific information on pa...

Page 8: ...gnments follow IEEE 802 3 specifications All Infoblox Ethernet ports are auto sensing and automatically adjust to standard straight through and cross over Ethernet cables SFP SFP Ports The Infoblox 4000 series appliances ship with three or with four 4 SFP or SFP transceivers depending on the appliance model and the ordered configuration Depending on the options you have selected Infoblox 4000 seri...

Page 9: ...to 70 C Single 3 3V power supply Maximum link length of 10km Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Infoblox SFP Short Range 10GbE SR fiber Transceiver Infoblox part number IB SFPPLUS SR Hot pluggable SFP footprint Supports 9 95 to 10 5 Gb s bit rates Power dissipation 1W RoHS 6 compliant lead free Commercial temperature range 0 C to 70 C Single 3 3V p...

Page 10: ...chassis for DC based 4000 Series systems see Ground Lug Installation DC of this guide Systems Only Figure 7 Infoblox 4000 Series Rear View with Four SFP Interfaces shows the rear view of the Infoblox PT 4000 10GE appliance Figure 8 Figure 8 Infoblox PT 4000 10GE appliance Rear View with Four SFP SFP Interfaces ...

Page 11: ... reserved for future use ND 4000 TR 4000 Reporting LAN2 Port LAN2 connects a NIOS appliance to the network LAN2 is disabled by default You enable the LAN2 port and define its use through the Grid Manager after the initial setup Console Port A male DB 9 serial port for a console connection to change basic configuration settings and view basic system functions through the CLI command line interface ...

Page 12: ...table appliance Dimensions 3 44 H x 17 54 W x 27 5 D 8 75 cm H x 44 55 cm W x 69 85 cm D Weight Approximately 61 00 pounds 27 66 kg Ethernet Ports MGMT HA LAN1 LAN2 auto sensing 1000Base TX MGMT HA LAN1 LAN2 auto sensing 10000Base TX Environmental Specifications Operating Temperature 41 F 104 F 5 40C Storage Temperature 22 to 140 degrees F 30 to 60 degrees C Operating Relative Humidity 10 to 90 no...

Page 13: ... Installation and Removal Guidelines After receiving a shipped Infoblox 4000 Series appliance with SFP or SFP support Infoblox recommends installing the transceivers into your appliance before turning power on to the system for the first time Pay heed to the interface configuration required for your appliance deployment when inserting your SFP SFP transceivers Should circumstances require you to s...

Page 14: ...mechanisms will click indicating that you can safely withdraw the system from the rack without accidentally pulling it free 9 Snap the Infoblox 4000 Series appliance into place and fasten it to the rack using the retainer screws provided in the accessory kit For further information refer to the instructions shipped with the accessory kit 10 Pull down the retention levers on both sides of the appli...

Page 15: ...nce can then operate on the other To power the appliance For each power supply connect a power cable between the power connector on the back of the appliance and a properly grounded and rated power circuit that meets the provisions of the current edition of the National Electrical Code or other wiring rules that apply to your location Make sure that the outlet is near the appliance and is easily a...

Page 16: ...Base system at https supp ort infoblox com Trunking Disable EtherChannel Disable IGMP Snooping Disable Port Channeling Disable Speed and Duplex settings Match these settings on both the Infoblox appliance and switch Disable other dynamic and proprietary protocols that might interrupt the forwarding of packets Use the Grid Manager from a management system to access set up and administer the Infoblo...

Page 17: ...68 Recommended 1280 x 1024 or better CLI Access Secure Socket Shell SSH client that supports SSHv2 Terminal emulation program such as Minicom or Hilgraeve Hyperterminal Grid Manager fully supports Microsoft Internet Explorer 11 x and 10 x when you enable compatibility view in the browser Features in the Repo tab may not function properly if you disable compatibility view In the browser go to to en...

Page 18: ...ormation about cabling the appliance to a network refer to Cabling the Appliance to a Network Connect the appliance to a power source and turn on the power For information about powering the appliance refer to Powering On the Infoblox 4000 Series Appliance The appliance automatically sends a lease request to the DHCP server which assigns a DHCP lease and a dynamic IP address to the appliance The D...

Page 19: ...es the FQDN fully qualified domain name of the appliance The process is straightforward For information about certificates refer to the N IOS Administrator Guide 3 Log in using the default user name and password and admin infoblox Note User names and passwords are case sensitive 4 Read the Infoblox End User License Agreement and click to proceed The Setup Wizard opens for defining basic network an...

Page 20: ...pecified log file up to 10 previous logfiles will be preserved The two main groups of NIOS CLI commands are and To see the complete list of the set commands enter after the set show help set command prompt Likewise to see a complete list of the show commands enter For information about the CLI commands refer to help show the Infoblox CLI Guide Infoblox 4000 Series Field Replaceable Units The Infob...

Page 21: ...ray In the event of a disk failure you must replace the failed disk with one that is qualified and shipped from Infoblox and has the same disk type as the rest of the disks in the array The appliance displays information about mismatched disks in the Description column in the panel The Infoblox 4000 Series Detailed Status appliances use only the disk type For the array to function properly all dis...

Page 22: ...ld damage the array If you insert a replacement drive into a live array and the controller doesn t recognize the drive power down the appliance All disks in the RAID array must have the same disk type for the array to function properly In the unlikely event that two disk drives fail simultaneously and the appliance is still operational remove and replace the failed disk drives one at a time Rebuil...

Page 23: ...outlet illustrates the process of replacing an AC power supply Figure 15 for the IInfoblox 4000 Series Figure 15 Removing an Infoblox 4000 Series AC Power Supply To replace an Infoblox 4000 Series AC power supply do the following Turn off the power supply Disconnect the AC power cable from the power outlet Gently push back the red catch release lever grip the power supply handle and pull the power...

Page 24: ...n see Ground Lug Installation DC Systems Only Important Retain your original AC power supplies for possible future RMAs When you remove the AC power supplies for new DC power supplies ensure that you keep the original AC power supplies in a safe plac e for use in RMA situations For appliance RMAs you must replace the DC power supplies in the appliance with its original AC power supplies RMA shipme...

Page 25: ...ed spinning and must be replaced 6 Figure 18 shows a four fan module configuration The system fans can be removed from their installation base and replaced A pair of small handles reside on the top of each fan module which you grasp with fingertips when pulling the unit out of the system Pay attention to unit alignment and placement before removing from the system Figure 18 System fan removal pull...

Page 26: ...ries DC PSU Rev 2 IB 4000 R2 PSU DC FRU only Y Y Y Y Infoblox IB Type 3 Disk Assembly Rev 2 IB 4000 R2 DISK HDD300 FRU only Y Y Y Y Infoblox IB 4000 Series fan set Rev 2 IB 4000 R2 FAN FRU only Y Y Y Y Infoblox IB 4000 Series 14AWG AC Power Cord IB POWER CORD 4K Contact Infoblox Support Y Y Y Y Infoblox 4000 Series SFP SFP Transceivers Infoblox offers SFP SFP transceivers of various types for 1GbE...

Page 27: ...able 12 Infoblox 4000 Series International AC Power Cords Infoblox Part Number International Item Description IB POWER CORD 4K AUS Power Cord Infoblox 4000 series Australia IB POWER CORD 4K BR Power Cord Infoblox 4000 series Brazil IB POWER CORD 4K CL Power Cord Infoblox 4000 series Chile Italy IB POWER CORD 4K CN Power Cord Infoblox 4000 series China IB POWER CORD 4K EU Power Cord Infoblox 4000 s...