background image

3

4

Don't use or store the chair in wet environments (i.e., near

 

the swimming pool or in the bathroom).
Keep the chair and remote control dry all the time.

Unplug the power if any damage has occurred to the cord
or plug.

Caution

Unplug the power before cleaning the chair.
Unplug the power after using the chair.

Turn the power switch to the OFF position and unplug the 
power after each massage session

.

Unplug the power immediately in the case of a power
outage.

Do NOT use a plug adapter. If the enclosed plug does not fit 
your outlet, please don't change the plug by yourself. Find a 
professional electrician to install a properly-fitted outlet.

Hold the plug to unplug the power. Never pull the wire to
unplug the chair.

Safety Instructions

Safety Instructions

Preparation

Preparation

To avoid water damage
or electric shock.

To avoid electric shock.

To prevent electric shock

 

or fire hazard.

To avoid accidents

To avoid electrical damage or 
accidents.

Grounding Instructions

Replacing the Fuse

 

The chair is equipped with a grounded cord. The plug must be 

    plugged into a properly-installed and fitted outlet.

 

If the fuse is burnt out, turn off the switch and unplug the power. 

    Open the lid covering the fuse, which is located in the switch box. 
    Use a new fuse of the same size to replace the old one, then close the lid.

Position the chair minimum of 4 inches from the wall 
to allow for sufficient space to recline up and down.

Place and operate the chair on a flat, level surface.

Insert the plug into a properly-grounded 
outlet ONLY. The cord or plug should 
not be bent or cut off. 

Don't press or step on the massage heads.
Don't put hands between the working

 

massage heads.

Don't put hands or feet in the gap of mechanical parts.
Don't drop or embed anything into the massage chair openings.
Don't stand, sit, or place anything on the back rest, arm rest

 

or 

leg rest.
Don't stand on the chair during operation.
Don't move the chair during operation.
Don't pull out the plug or turn off the power during operation.
Don't put extremities between or beneath the leg rest

.

Don't use the massage chair while wearing hair ornaments

.

Empty pockets before every massage.
Don't sit or press on the backrest when the chair is in the 
reclined position.
Don

'

t use the chair on bare skin or while wearing thin

clothing, as this can cause skin irritation.

Caution

Keep the chair away from stove or other heating appliances.
Do not place the chair directly under the sun or in 
locations of extreme temperatures.

 

Do not use electric blankets or other heating products 
on the massage chair

.

To avoid sudden falls or damage.

The maximum suggested operating time is 30 minutes.
Continuous massage in the same position for long 
periods of time may cause discomfort.

Before sitting on the chair, inspect everything to
confirm that the massage heads and other parts are
in the correct position.

Give your body time to recover.

To avoid electric shock in the case 
of a leakage or breakdown

.

To prevent upholstery from becoming
faded, discolored, deteriorated, or 
hardened.

Do not use the chair outdoors. 

Keep the chair away from heat, moisture, sharp objects,

 

and corrosive materials.

Make sure the plug is completely inserted into the 
outlet.

To reduce risk of short circuit and any

 

fire

 

hazard

.

To avoid injury when powering on or 
off

Turn off all controls before removing plug from outlet.

Checking for any damage on wire. Ensure it has not 
come into contact with any liquid or moisture.

Please make sure that the power switch is in the

OFF

” 

position before inserting the plug into the outlet.

To ensure chair can fully recline.

To avoid accidental injury.

To avoid accident or injury.

Do not place in a heavily dusty or flammable environment.

Do not put the chair in a cramped space or in an area with
poor circulation. 

Remote control should be stored in the pocket or on the 
bracket when not in use. 

Summary of Contents for Presidential

Page 1: ...Please read SAFETY INSTRUCTIONS carefully before using the chair User s Manual Presidential Massage Chair ...

Page 2: ...vitality 11 The armrests are also equipped with pulsating air pressure massage functions to promote blood circulation and total relaxation through your fingertips 12 The waist and hip areas also include multiple air bags to assist with spinal correction and loosen muscular tension in the lumbar region 13 With Chinese medicinal heating on the waist the Presidential promotes blood circulation to rel...

Page 3: ... the chair into a suitable and properly grounded outlet only Make sure the plug is completely inserted into the outlet to reduce risk of short circuit or fire When not in use stop all massage functions turn all controls to the OFF position and unplug Ensure there are no obstacles under behind or in front of the chair when reclining extending or retracting it During operation if at any point you ex...

Page 4: ...back rest arm rest or leg rest Don t stand on the chair during operation Don t move the chair during operation Don t pull out the plug or turn off the power during operation Don t put extremities between or beneath the leg rest Don t use the massage chair while wearing hair ornaments Empty pockets before every massage Don t sit or press on the backrest when the chair is in the reclined position Do...

Page 5: ...r Back Air Bag Arm Air Bag Side Seat Air Bag Calf Air Bag Foot Air Bag Foot Roller Preparation 靠背 Fuse holder Power Cord Socket Power Switch Power Case Backrest Remote Control Pocket Right Shoulder Air Bag Massager Seat Back Seat Cushion Right Armrest Legrest Footrest LED light Left Shoulder Air Bag Massager Left Armrest Base Head Cushion Right Speaker USB Port Lumbar Heat LED Light ...

Page 6: ...actuator Legrest and footrest assembly Left armrest convert frame assembly Shoulder device assembly RK08 massage machine Back cover assembly B Backrest assembly Mechanical Components Diagram NO Q ty Name Mechanical Components List Explosion Diagram Preparation Preparation Mechanical Components List Q ty Name NO Right armrest assembly Right side fender Left side fender Left amrest assembly Power ca...

Page 7: ...t Device Remove the left and right armrests from the armrest box Hold each side of an armrest and take it out slowly one piece at a time Please note The armrest is placed upside down in the box Place the armrest box on a table or on level ground be careful to avoid scratching either armrest Step 2 How to Assemble the Leg Rest Axis cover Hanger Bolt Socket Air nozzle Axis Power line plug Air tube L...

Page 8: ...the rubber cap inside the armrest and loosen the screw inside the hole Tilt the armrest a little upwards and disconnect the air tubes and power cord Continue to tilt the armrest upwards to dismantle it Re insert the rubber plug into the round holes inside the armrest Power Box Socket Chair s Initial State Installation Installation 3 Installation 4 Installation Installation Installation Step 3 How ...

Page 9: ...cts 2 Confirm there is sufficient space for the chair to fully extend Chair Operation Recommendations Adjustment Before Massage Safely Moving Your Massage Chair Adjusting the ChairBeforeYourMassage Caution Do not move the chair during operation in case of accidents or damage Chair Operation How to Move Your Chair Bind the cables and put them on the seat to avoid damage while moving the chair Do no...

Page 10: ...tting 3 In the ON status press this key to adjust the air intensity either in auto mode or in the air massage program 3D 3D 3D 3D Air Intensity Hot Rocks On Off Auto Menu Zero Set function by pressing Menu key Speed Width Intensity 3D 20 min Manual Control Manual Control Up Down Right Leg Rest Up Backrest Down On Off Auto Confirm Button Leg Rest Down Zero Gravity Menu Manual Control Chair Operatio...

Page 11: ...elief Stretch Music Sync Renew Calming Special Select by the navigation keys Auto Manual Airbag Roller Heating Timer Settings Stop Refresh Energy Revive Active Relax Healing Menu Press the Menu button in the main interface to switch to the Menu interface Here you can set all massage functions Press the Menu button in the Menu interface to exit and return to the Main interface Mode Position Width S...

Page 12: ...power switch on the bottom of the back of chair after the rollers return to the storage position Unplug the power cord from the outlet 1 Before using lift the pillow back cushion etc to check if the PU material is broken If there is damage please stop using unplug the chair and contact our tech support for repair 2 Only plug into a grounded outlet Warning Attention 1 Before sitting down make sure ...

Page 13: ...ricity from the outlet Attention Hold the plug properly and pull as illustrated below Do not pull by the cord Clean the chair if necessary Attention After using press ON OFF to end all massage functions and wait for the chair to return to its original position Turn off the power and unplug the chair from the outlet Keep the chair away from moisture dirt and old insulation to prevent damage Restora...

Page 14: ...massage chair to rest for at least half an hour before next use Re connect the electricity to power The plug is not properly inserted into the electrical outlet This is the sound of the air pump motor and mechanical parts Normal wear and tear on inner parts after much use The massage chair suddenly becomes much louder during operation Remove the obstacles turn off the power and allow the massage c...

Page 15: ...del Input voltage Safety design AC120V 60Hz AC220V 50 60Hz AC240V 50Hz Class NW GW Packing size Power Main body 253 302 lbs Armrest 32 43 lbs Legrest footrest 66 76 lbs Main body 59 8 31 38 Armrest 38 5 15 5 28 Legrest footrest 23 20 24 L W H Presidential ...

Reviews: