32
Ordercode: 41526
Infinity iW-740 RDM
Channel 20 – Dynamic LED control
(CH6, CH7, CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH16 or CH18 (program 1-21) must be set
between 1-255 and CH8 between 5-9
)
0-2
No function
3-8
Program 1
9-14
Program 2
15-20
Program 3
21-26
Program 4
27-32
Program 5
33-38
Program 6
39-44
Program 7
45-50
Program 8
51-56
Program 9
57-62
Program 10
63-68
Program 11
69-74
Program 12
75-80
Program 13
81-86
Program 14
87-92
Program 15
93-98
Program 16
99-104
Program 17
105-110
Program 18
111-116
Program 19
117-122
Program 20
123-128
Program 21
129-134
Program 22 with color flow
135-140
Program 23 with color flow
141-146
Program 24 with color flow
147-152
Program 25 with color flow
153-158
Program 26 with color flow
159-164
Program 27 with color flow
165-170
Program 28 with color flow
171-176
Program 29 with color flow
177-182
Program 30 with color flow
183-188
Program 31 with color flow
189-194
Program 32 with color flow
195-200
Program 33 with color flow
201-206
Program 34 with color flow
207-212
Program 35 with color flow
213-218
Program 36 with color flow
219-224
Program 37 with color flow
225-230
Program 38 with color flow
231-236
Program 39 with color flow
237-242
Program 40 with color flow
243-248
Program 41 with color flow
249-255
Program 42 with color flow
Channel 21- Speed Dynamic LED control (CH20 must be set between 3-255
)
0-255
Gradual adjustment Speed, from slow to fast
Channel 22- Fade time Dynamic LED control (CH20 must be set between 3-255
)
0-255
Gradual adjustment Fade time, from slow to fast
Channel 23 – Background dimmer
0-255
Dimmer intensity, from dark to brightest