background image

20 

LT5889 issue 7(10/12)

 

 

 

Infinity Fires 

  
 

 Infinity 600 CF 

 

THIS IS YOUR EXTENDED FIVE YEAR PARTS 

WARRANTY 

PLEASE  READ  IT  CAREFULLY  AND  ENSURE  YOUR  INSTALLER  HAS  FILLED  IN 
THE  FIRST  PORTION,  KEEP  IT  IN  A  SAFE  PLACE  SO  THAT  IT  IS  AVAILABLE 
WHEN YOUR 

GAS SAFE

 ENGINEER CARRIES OUT THE ANNUAL SERVICE. 

 

THIS IN NO WAY REDUCES YOUR STATUTORY RIGHTS 

 

THE  WARRANTY  COMMENCES  FROM  THE  DATE  OF  PURCHASE  YOU  MUST 
RETAIN YOUR RECEIPT OR INVOICE AS PROOF OF PURCHASE. 
THIS  EXTENDED  WARRANTY  SPECIFICALLY  EXCLUDES  SOFT  REFRACTORY 
COMPONENTS, THE BULB AND ANY BATTERIES. 

 
Terms and Conditions 
1.  The appliance must be installed by a Gas Safe registered person. 
2.  The appliance must be used in accordance with the 

user’s instructions. 

3.  The appliance must be serviced annually by a Gas Safe registered person. 
4.  The service log must be correctly filled out and the record of annual services must be up  to date  and supported by 

receipts in each case. 

5.  This warranty is not transferable and relates to the original installation only. 
6.  The Registration Form must be correctly filled out and returned. 
7.  The appliance has not been subjected to misuse or accident or been modified or repaired by any person other than 

the authorised employee or authorised representative of Charlton and Jenrick Ltd. 

8.  The registration form must be returned within 3 months of purchase. 
 

 

INFINITY HELPDESK NUMBER 0845 5195991 

 
 
 
 
 
 
 
 

Summary of Contents for 600 CF

Page 1: ...TIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND on...

Page 2: ...panel 10 INSTALLATION INSTRUCTIONS SECTION FIVE Appliance Data 12 SECTION SIX Regulations and Warnings 13 SECTION SEVEN Siting the Appliance Flue Class1 14 Installation Compatibility plinth hole in w...

Page 3: ...ervicing installation it is recommended that it is of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped i...

Page 4: ...REGULATIONS The Building Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the applian...

Page 5: ...the lighting procedure see note on page 7 c With the appliance lit by pressing key the operational mode is switched from manual to Room thermostat setting and vice versa When Room thermostat mode is...

Page 6: ...g pressed key at least for 5 seconds the temperature unit changes from Celsius to Fahrenheit degrees and vice versa Battery level indication Handset When the batteries have to be changed in the handse...

Page 7: ...emove the battery holder from within the protective cover and replace the six high power alkaline C batteries as a complete set WARNING batteries will overheat if fitted incorrectly when fitting the b...

Page 8: ...his may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary t...

Page 9: ...nts provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on...

Page 10: ...aning and Layout Continued Fuel Bed Layout LOG Locate air tray within the slot on shelf assembly Place 1 2 Log Shapes to the front of the Stainless Steel Burner Place a thin layer of Vermiculite on to...

Page 11: ...00 CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Fuel Bed Layout LOG Place shapes 3 to 5 Log Shapes on top of the Air Tray as shown Bridge Log shapes 6 7 as shown Bridge Lo...

Page 12: ...rigid or rigid Data Badge Location Located on the left hand side of the base of the appliance behind the trim Battery Remote handset 3 x AAA 1 5 V Appliance 6 x 1 5V C Cell high power alkaline NOTE T...

Page 13: ...etent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if approp...

Page 14: ...tion of natural draught Ensure that the air entering the appliance below the lower edge of the decorative trim is not restricted If the appliance is fitted above a forward projection hearth the base o...

Page 15: ...mble in reverse order Ensure that the trim is the correct orientation CONNECTING THE GAS SUPPLY Note An isolation valve may be fitted in the gas supply adjacent to inlet pipe For a concealed connectio...

Page 16: ...ce located on page 3 of this booklet before laying or replacing any refractory material In the event of replacing fuel bed components please use only the specified number of components as illustrated...

Page 17: ...vertical side flange of the box Avoid placing magnets along the top section of the trim Offer the decorative trim up squarely and centrally and push into position To remove the decorative trim simply...

Page 18: ...and glass assembly Section 3 Remove the loose fuel bed components Disconnect battery leads and remove appliance battery Remove the fixing screw from the EDB fixing bracket Detach remote control eye f...

Page 19: ...end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Remove the fixin...

Page 20: ...ust be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the user s instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The...

Page 21: ...helpdesk Model Infinity 600 CF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance...

Page 22: ...e of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration N...

Page 23: ...LS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 600 CF Serial No Date of Purchase This information can be found...

Page 24: ...Glass Panel 600 CF Log set Containing 1x bag vermiculite Part No 5902 Silicone Sealing Strip 4818 AAA Battery 3 Remote Control Hand Set Restrictor Plate Part No 5990 Handset Holder 5910 Battery Holde...

Reviews: