background image

13 

LT5889 issue 7(10/12)

 

 

 

 

600 CF 

Installation Instructions

 

 

 

SECTION SIX 

Regulations and Warnings 

 

 

  This appliance must only be installed in Great Britain or Ireland. 

  The appliance is suitable for use on natural gas only. 

 

GB (Great Britain)

 This fire does not normally require purpose build ventilation. 

 

IE (Ireland)

 Permanent ventilation must comply with the current edition of IS813. 

 

In GB

(Great Britain)

 

It  is  the  law  that  all  gas  appliances  must  be  installed  by  a  competent  person;  i.e.  a  GAS  SAFE 
registered installer, in accordance with the Current Gas Safety (Installation And Use) Regulations 
(as  amended),  all  relevant  parts  of  the  local  and  national  building  regulations  and  all  relevant 
recommendations of the following British Standards. Failure to do so could lead to prosecution. 

The following are relevant codes of practice and British Standards: - 
B.S. 5871  

 

 

 

 

 

 

B.S. 5440 PART 1 & PART 2 

 

 

 

B.S. 6891  
This appliance must  be  installed  to  current  versions  of the  above  standards  and  include any 
relevant amendments to:- 
The Building Regulations Issued By The Department Of The Environment.

 

The  Building  Standards  (Scotland)  (Consolidated)  Regulations  Issued  By  The  Scottish 
Development Office.  

 

IN IE, (Ireland)

 

The  appliance  must  be  installed  by  a  competent  person  and  installed  in  accordance  with  the 
current  edition  of  I.S.813  Domestic  Gas  Installation,  the  current  building  regulations,  and  the 
current ETCI rules for electrical installation, if appropriate.   

 

Prior  to  the  installation  ensure  that  the  local  distribution  conditions  (identification  of  type  of  gas 
and pressure) and adjustment of the appliance are compatible. (G20 & G21). 

 

IMPORTANT NOTE: -  
The fire front (fret) or fascia supplied must be used with this appliance.

  

 

WARNINGS 

  The glass front of the fire act as a dress guard,  conforming to BS 1945 (1971) and satisfies the 

heating  appliance  regulations  (1991)  However,  a  guard  conforming  to  BS6539  (1984)  must  be 
used to protect young children, the elderly or infirm. 

 

This appliance incorporates a safety device in the form of an Oxygen depletion system. IT 
MUST  NOT  BE  ADJUSTED  OR  PUT  OUT  OF  OPERATION!  THIS  IS  A  NON-SERVICABLE 
ITEM  AND  MUST  BE  EXCHANGED  AS  A  COMPLETE  ASSEMBLY;  USING  ONLY  THE 
ORIGINAL MANUFACTURER'S PART.

 

  A suitable proprietary fire surround with a 150°C minimum rating must be provided. 

  During  initial  firing,  an  odour  may  be  evident.  This  is  the  starch  binder  used  during  the 

manufacture of the fibre components of the fire, and there are 

no

 

harmful

 effects produced. 

 

Care  must  be  taken  to  prevent  any  damage  being  caused  to  surrounding  soft  furnishing  or  decoration;  e.g.  many 
embossed vinyl wall coverings may become discoloured if placed too close to the appliance. 

 

Summary of Contents for 600 CF

Page 1: ...TIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND on...

Page 2: ...panel 10 INSTALLATION INSTRUCTIONS SECTION FIVE Appliance Data 12 SECTION SIX Regulations and Warnings 13 SECTION SEVEN Siting the Appliance Flue Class1 14 Installation Compatibility plinth hole in w...

Page 3: ...ervicing installation it is recommended that it is of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped i...

Page 4: ...REGULATIONS The Building Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the applian...

Page 5: ...the lighting procedure see note on page 7 c With the appliance lit by pressing key the operational mode is switched from manual to Room thermostat setting and vice versa When Room thermostat mode is...

Page 6: ...g pressed key at least for 5 seconds the temperature unit changes from Celsius to Fahrenheit degrees and vice versa Battery level indication Handset When the batteries have to be changed in the handse...

Page 7: ...emove the battery holder from within the protective cover and replace the six high power alkaline C batteries as a complete set WARNING batteries will overheat if fitted incorrectly when fitting the b...

Page 8: ...his may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary t...

Page 9: ...nts provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on...

Page 10: ...aning and Layout Continued Fuel Bed Layout LOG Locate air tray within the slot on shelf assembly Place 1 2 Log Shapes to the front of the Stainless Steel Burner Place a thin layer of Vermiculite on to...

Page 11: ...00 CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Fuel Bed Layout LOG Place shapes 3 to 5 Log Shapes on top of the Air Tray as shown Bridge Log shapes 6 7 as shown Bridge Lo...

Page 12: ...rigid or rigid Data Badge Location Located on the left hand side of the base of the appliance behind the trim Battery Remote handset 3 x AAA 1 5 V Appliance 6 x 1 5V C Cell high power alkaline NOTE T...

Page 13: ...etent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if approp...

Page 14: ...tion of natural draught Ensure that the air entering the appliance below the lower edge of the decorative trim is not restricted If the appliance is fitted above a forward projection hearth the base o...

Page 15: ...mble in reverse order Ensure that the trim is the correct orientation CONNECTING THE GAS SUPPLY Note An isolation valve may be fitted in the gas supply adjacent to inlet pipe For a concealed connectio...

Page 16: ...ce located on page 3 of this booklet before laying or replacing any refractory material In the event of replacing fuel bed components please use only the specified number of components as illustrated...

Page 17: ...vertical side flange of the box Avoid placing magnets along the top section of the trim Offer the decorative trim up squarely and centrally and push into position To remove the decorative trim simply...

Page 18: ...and glass assembly Section 3 Remove the loose fuel bed components Disconnect battery leads and remove appliance battery Remove the fixing screw from the EDB fixing bracket Detach remote control eye f...

Page 19: ...end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Remove the fixin...

Page 20: ...ust be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the user s instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The...

Page 21: ...helpdesk Model Infinity 600 CF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance...

Page 22: ...e of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration N...

Page 23: ...LS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 600 CF Serial No Date of Purchase This information can be found...

Page 24: ...Glass Panel 600 CF Log set Containing 1x bag vermiculite Part No 5902 Silicone Sealing Strip 4818 AAA Battery 3 Remote Control Hand Set Restrictor Plate Part No 5990 Handset Holder 5910 Battery Holde...