PREVENTIVE MAINTENANCE

**** WARNING ****

dANgER OF ELECTRICAL ShOCK, TURN OFF ALL POwER SUPPLYINg ThIS EqUIPmENT

PRIOR TO MAINTENANCE. 

To ensure longer component life and trouble-free operation, minor preventive maintenance procedures 

should be performed at regular intervals, for example once every year.  More frequent inspection intervals 

would be needed for more severe operating conditions and larger number of hours of continuous operation.
1. Remove front and side panels and at each service inspection any accumulated dust, dirt or foreign

particles should be carefully removed.  Special care should be exercised in cleaning the thyristors

(SCR’s), heat sinks and the control assembly.

2. Inverse Parallel Silicon Rectifiers (SCR’s) or Thyristors - The silicon controlled rectifiers (SCR’s or

Power Mods) usually fail in the shorted mode.  When this happens, normally the fusible link in series

with the SCR will be blown open to clear the short and prevent damage to the transformers.  If a blown

SCR is suspected, contact Transtector for service.

3. A simple performance checklist has been developed for use in maintenance.  See 

“Performance

Checklist” 

and check off items 1-7.

4. After items 1-7 have been checked on the 

“Performance Checklist”

, the next step is to check the

operation of the system.

5. Replace front and side panels.  Turn unit on with no load.  Check item 8 on the 

“Performance Checklist”

6. Turn on loads and check items 9-10 off the 

“Performance Checklist”

.

7. Check to make sure all fans are operational and check off item 11.

NOTE:

 Preventive Maintenance Plans are available.  Please contact the Customer Support Group for

information.  Call 1-800-882-9110 X6112.

Rick Ribbeck

Phone: (O) 208-635-6400 Ext. 5867 | (M) 208-762-6112

E-mail: [email protected]

E-mail: [email protected]

Transtector Systems

10701 Airport Dr.

Hayden Lake ID 83835

SERVICE

Transtector shall provide immediate phone support/consultation and if possible, same day parts shipment. 

(contact must be prior to 12:00 PM PST).  If necessary, on site service shall be scheduled the same day 

for service to be conducted within 24 to 48 hours, based on customer requirements.   Typical service hours 

are 8 AM to 5 PM Monday through Friday. 

Summary of Contents for Transtector 700 AV/T-S Series

Page 1: ...th Voltage Regulation 60 Hz Owners Manual Quad Output Power Conditioner for Novalis TX with ExacTRAC and OBI Options 160K i 60 Hz Model Front Access Design Important safety instructions save these ins...

Page 2: ...nary Installation 6 7 Weights BTU and Dimensions 7 Input Wire Size Grounding and Output Wiring 8 9 Installation 10 13 Bypass Switch 14 Start up and Operation 15 Preventive Maintenance 16 Performance C...

Page 3: ...t by replacing it in the original container if possible If the original container is not available it is recommended that all openings that lead internally into the unit are covered so that dust water...

Page 4: ...the output Over temperature thermal sensors are strategically located at critical points on the regulator assemblies and transformer The main AC input circuit breaker must be turned off in order to re...

Page 5: ...IONS CAUTION RISK OF ELECTRICAL SHOCK AND HIGH SHORT CIRCUIT CURRENT THE FOLLOWING PRECAUTIONS SHOULD BE OBSERVED WHEN WORKING ON THE UNIT 1 REmOvE wATChES RINgS OR OThER mETAL ObjECTS 2 USE TOOLS wIT...

Page 6: ...t the top Therefore it should be installed in a clean dry place with enough clearance to allow a free flow of air Allow a minimum of 36 in front of the 700AV T S for installation operation and mainten...

Page 7: ...DIMENSIONS 75 kVA 2 194 lbs 995 18 kg 5 115 10 230 34 5 w x 35 875 d x 76 h 87 63 cm x 91 12 cm x 193 04 cm Stated BTU s Hr is at 75kVA rated load 100 duty cycle Operational BTU s Hr is typically at...

Page 8: ...ut ground lug TA 250 max wire range 6 AWG 250 MCM one piece E Output is a 4 wire 5 including ground If four 4 current carrying conductors are used in a raceway the neutral is assumed to be current car...

Page 9: ...subject to local codes Verify with a local electrician inspector The unit is constructed using an isolation transformer and is considered to be a separately derived system It should be grounded in ac...

Page 10: ...i 60 Hz Power Conditioner Owners Manual 10 INSTALLATION CABINET OUTLINE FRONT VIEW BOTTOM VIEW 76 000 3 000 AIR INLET FRONT VIEW 562 x 1 000 34 500 OUTPUT CONDITIONED POWER INPUT OUT OF RANGE ALERT C...

Page 11: ...ACCESS AREA TOP INPUT OUTPUT OUTPUT FILTER OUTPUT TERMINATIONS AND CURRENT TRANSFORMERS REMOVABLE TOP PANEL PROVIDES ACCESS TO TRANSFORMER TERMINATION ACCESS AREA BOTTOM INPUT OUTPUT 14 000 6 895 23 0...

Page 12: ...0K i 60 Hz Power Conditioner Owners Manual 12 INSTALLATION continued CABINET OUTLINE RIGHT SIDE VIEW TERMINATION ACCESS AREA OPTIONAL SIDE OUTPUT 4 850 8 250 4 500 2 810 35 500 RIGHT SIDE VIEW AIR FLO...

Page 13: ...e load current is not to exceed 80 of the output breaker s rating and not to exceed the rated total current BOTTOM ACCESS WIRE RUN ROUTE SEPERATION PLATE OUTPUT METERS 70A 480V OUTPUT BREAKER 60A 480V...

Page 14: ...rs NORMAL MODE With the switch in the normal position the Series 700 AV T S will provide clean and regulated power to the critical loads The Series 700 AV T S should have the switch in the normal posi...

Page 15: ...n the main AC input breaker 5 Verify that the output voltage is within the specified range 6 Verify output phase rotation is correct 7 Turn the system off 8 Connect the loads one at a time and repeat...

Page 16: ...a blown SCR is suspected contact Transtector for service 3 A simple performance checklist has been developed for use in maintenance See Performance Checklist and check off items 1 7 4 After items 1 7...

Page 17: ..._Fan Connections______Transformer Connections 7 Exercise all circuit breakers ______Input Breaker______Output Breakers 8 Input Output Voltage Checks Adjust as Needed No Load Input No Load Output A B__...

Page 18: ...ITHIN THE ENCLOSURE OF THE POWER SUPPLY SYSTEM CAUTION MUST BE TAKEN WHEN WORKING WITH THE ENCLOSURE IT IS RECOMMENDED THAT ALL WORK BE PERFORMED BY QUALIFIED ELECTRICAL PERSONNEL ONLY Rick Ribbeck Ph...

Page 19: ...13789 13789 CONTROL RELAY 1 13696 13696 13696 13696 PILOT LIGHT RED ALERT 3 109054 109054 109054 109054 PILOT LIGHT GREEN A B C 3 107829 107829 107829 107829 PILOT LIGHT INPUT OUT OF RANGE 3 23943 239...

Page 20: ...or GOLD PLUS PLAN Factory servicemen are not included in this warranty This Warranty is in lieu of all other warranties expressed or implied The giving of or failure to adhere to any advice or recomme...

Page 21: ...21 1402 001 APPENDIX A RELATIVE DRAWINGS SCHEMATICS...

Page 22: ...ERIES 700A FRONT ACCESS CABINET OUTLINE COPPER BUS OUTPUT TERMINATIONS TO TOP CUSTOMER S INPUT CONNECTS INPUT CIRCUIT BREAKER TERMINATION ACCESS AREA TOP INPUT OUTPUT OUTPUT FILTER OUTPUT TERMINATIONS...

Page 23: ...ke ID 83835 036 20GA 075 14GA 048 18GA 105 12GA 060 16GA 135 10GA AIR FLOW RIGHT SIDE VIEW 4 750 2 812 4 500 8 250 FRONT AIR OUTLET 35 515 15 875 3 716 5 750 34 389 23 000 1 875 3 364 6 895 14 000 FRO...

Page 24: ...5 036 20GA 075 14GA 048 18GA 105 12GA 060 16GA 135 10GA TOP VIEW FRONT D CARLSON 1 18 2008 1 4 SCALE TOLERANCE THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF TRANSTECTOR ANY REPRODU...

Page 25: ...Wp min 1785 0 lbs x 0 85 1517 25 lbs Fp 0 45 x 2777 25 1249 76 lbs Vertical Force Fp 0 15 x 2777 25 416 58 lbs Moment Mo 33 00 x 1249 76 41242 08 in lbs Tension Fp x Cg V4 3213 6 lbs Corners a b 43 1...

Page 26: ...ming the process required in this manual Damage to the unit or personal harm could happen if proper precautions are not taken This symbol indicates that there is a risk of electrical shock if proper p...

Page 27: ...27 1402 001 NOTES...

Page 28: ......

Reviews: