Technical Reference Manual
002-29852 Rev. *B
19.5.1.10 PASS_SAR_WORK_VALID
Description:
Channel working data register 'valid' bits
Address:
0x40900180
Offset:
0x180
Retention:
Not Retained
IsDeepSleep:
No
Comment:
bits of disabled channels will be reset
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
WORK_VALID [7:0]
Bits
15
14
13
12
11
10
9
8
Name
WORK_VALID [15:8]
Bits
23
22
21
20
19
18
17
16
Name
WORK_VALID [23:16]
Bits
31
30
29
28
27
26
25
24
Name
WORK_VALID [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:31
WORK_VALID
R
RW
0
If set the corresponding WORK register is valid, i.e.
was already acquired during the current group scan. If
this bit is low then either the channel is not enabled,
not yet acquired or it is used as a pulse detect
channel.
1099
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers