Infineon TLD5542-1IVREG-EVAL User Manual Download Page 18

 

 

 

 
 

 

 
Published by 
Infineon Technologies AG 
81726 München, Germany 
 
© 2020 Infineon Technologies AG. 
All Rights Reserved. 

 
Do you have a question about this 
document? 
Email: 

[email protected] 

 
Document reference  

IMPORTANT NOTICE 

The information given in this document shall in no 

event  be  regarded  as  a  guarantee  of  conditions  or 

characteristics  (“Beschaffenheitsgarantie”) .  

 

With  respect  to  any  examples,  hints  or  any  typical 

values  stated  herein  and/or  any  information 

regarding  the  application  of  the  product,  Infineon 

Technologies  hereby  disclaims  any  and  all 

warranties  and  liabilities  of  any  kind,  including 

without limitation warranties of non-infringement of 

intellectual property rights of any third party.  

 

In addition, any information given in this document 

is  subject  to  customer’s  compliance  with  its 

obligations  stated  in  this  document  and  any 

applicable legal requirements, norms and standards 

concerning customer’s products and any use of the 

product  of  Infineon  Technologies  in  customer’s 

applications.  

 

The data contained in this document is exclusively 

intended  for  technically  trained  staff.  It  is  the 

responsibility of customer’s technical departments 

to  evaluate  the  suitability  of  the  product  for  the 

intended  application  and  the  completeness  of  the 

product  information  given  in  this  document  with 

respect to such application.     

 

 

For further information on the product, technology, 

delivery  terms  and  conditions  and  prices  please 

contact  your  nearest  Infineon  Technologies  office 

(

www.infineon.com

). 

 
WARNINGS 

Due to technical requirements products may contain 

dangerous substances. For information on the types 

in  question  please  contact  your  nearest  Infineon 

Technologies office. 

 

Except as otherwise explicitly approved by Infineon 

Technologies  in  a  written  document  signed  by 

authorized 

representatives 

of 

Infineon 

Technologies, Infineon Technologies’ products may 

not be used in any applications where a failure of the 

product or any consequences of the use thereof can 

reasonably be expected to result in personal injury. 

 

 

 

 

Edition 2020-05-25 
 
 
 
 
 
 
 
 
 
 
 
 

UM TLD5542-1IVREG_eval 

 

 

Trademarks  

All referenced product or service names and trademarks are the property of their respective owners. 

 

 

  

 

Summary of Contents for TLD5542-1IVREG-EVAL

Page 1: ...age regulation SPI for diagnostics and control Limp home function Fail safe mode EMC optimized device Spread spectrum Scope and purpose Scope of this user manual is to provide to the audience instruct...

Page 2: ...home mode microcontroller less 4 3 2 Set up as voltage regulator Limp home mode C less no PC GUI 5 3 3 Connecting the board to the IO stick 6 4 Infineon IO stick and Infineon Toolbox 8 4 1 Install an...

Page 3: ...he default configuration is constant current LED driver with 1 5 A maximum output current The output current can be increased up to 6A by changing RSHO If higher currents are needed the output filter...

Page 4: ...to start evaluating the TLD5542 1 without a microcontroller connection and without IO stick In limp home all the registers are set to their default value and the analog dimming is provided by the vol...

Page 5: ...3 A bypass RSHO with a solder joint on the resistor top 2 Connect J_EN LHI and PWMI jumpers Figure 6 Voltage regulator set LHI and EN jumpers populate solder jumps 3 Connect a 12 V power supply to th...

Page 6: ...remove jumpers 3 Connect the IO flat cable to j_uIO connector paying attention to the polarity pin 1 is marked on the PCB 4 Connect a 12 V power supply to the VIN connector Figure 10 Voltage regulato...

Page 7: ...rt procedure Figure 11 Voltage regulator with IO stick Adjust full scale 100 ADIM VOUT 7 Connect the load NOTE It is possible to adjust output voltage from 0 to full scale previously set by RVOLT with...

Page 8: ...n be downloaded via the Infineon Toolbox Plugs into the evaluation board via a standard 16 pin connector and allows easy interface to the microcontroller via USB for SPI CAN LIN communication etc Figu...

Page 9: ...g Wizard 1 Open the Manage tools tab 2 Search for Config Wizard for LED and click on Install button Figure 14 Install Config Wizard for LED 3 Select My Tools tab on Infineon Toolbox 4 Press Start on t...

Page 10: ...user interface Basic user interface allows simplified access to the main registers on TLD5542 1 e g analog dimming with a knob and provides direct feedback on TLD5542 1 status showing indicators for e...

Page 11: ...er interface compensation and EMC tabs 5 2 Engineering user interface The Engineering user interface allows the user to send a sequence of SPI commands to the TLD5542 1 PWMI and EN pin control is also...

Page 12: ...to describe each command with a comment and to save the list of commands by clicking on the Save button It is possible to set the delay applied before executing the next command in the Delay column t...

Page 13: ...5 C VIN 12 V see Figure 22 for power derating curve Please note that the module does not implement thermal protection so ensure proper cooling when output power exceeds the power derating curve The he...

Page 14: ...voltage VIN 5 5 35 V Power derating may occur for VIN 9 V Out voltage VOUT 2 3 3 51 22 5 V LED driver mode Voltage mode Output current IOUT 150 0 1500 5 mA A LED driver mode up to 6 A by changing RSHO...

Page 15: ...User Manual 15 of 18 Rev 1 00 2020 05 25 TLD5542 1IVREG EVAL evaluation board User Manual PCB layout 8 PCB layout Figure 23 PCB layout top view...

Page 16: ...User Manual 16 of 18 Rev 1 00 2020 05 25 TLD5542 1IVREG EVAL evaluation board User Manual Schematic 9 Schematic Figure 24 Schematic...

Page 17: ...l 17 of 18 Rev 1 00 2020 05 25 TLD5542 1IVREG EVAL evaluation board User Manual Revision history Revision history Document version Date of release Description of changes Rev 1 00 2020 05 25 Initial Us...

Page 18: ...applications The data contained in this document is exclusively intended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the...

Reviews: