User guide
34 of 45
V 1.0.1
2021-01-27
REF-AIRCON-C302A-IM564 user guide
Air conditioner application reference design kits
System performance
The pull-up resistor R121 is 2 k, and IMC302A’s temperature-related AD input voltage is shown in Figure 29.
Figure 29
NTC circuit and output voltage curve
The temperature value of overheat shutdown can be calculated as shown below and configured in MCEWizard
as shown in Figure 28.
The MCEWizard default setup is at 3.9 V, which sets the shutdown NTC temperature (
T
protection
) to about 90°C
when the whole IPM is in a heat balance state. Please note that there might be a 3 ~ 15°C temperature
difference between IPM NTC and the hottest point during motor power increase fast (non-thermal equilibrium
state).
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
5000
4 0
5 0
6 0
7 0
8 0
9 0
1 0 0
1 1 0
1 2 0
1 3 0
Ou
tp
u
t
vo
lta
ge
(m
V)
Temprature
(
℃
)
VFO output