Table 16. XRES AC Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
T
RESETWIDTH
Reset pulse width
1
–
–
µs
–
Table 17. Temperature Sensor Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
T
SENSACC
Temperature-sensor accuracy
–5
±1
5
°C
–40 to +85 °C
Table 18. SAR ADC DC Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
A_RES
Resolution
–
–
12
bits
A_CHNIS_S
Number of channels - single-ended
–
–
8
8 full-speed
A-CHNKS_D
Number of channels - differential
–
–
4
Diff inputs use neighboring I/O
A-MONO
Monotonicity
–
–
–
Yes
A_GAINERR
Gain error
–
–
±0.1
%
With external reference
A_OFFSET
Input offset voltage
–
–
2
mV
Measured with 1-V V
REF
A_ISAR
Current consumption
–
–
1
mA
A_VINS
Input voltage range - single-ended
V
SS
–
V
DDA
V
A_VIND
Input voltage range - differential
V
SS
–
V
DDA
V
A_INRES
Input resistance
–
–
2.2
k
A_INCAP
Input capacitance
–
–
10
pF
VREFSAR
Trimmed internal reference to SAR
–1
–
1
%
Percentage of Vbg (1.024 V)
Note
8. A maximum of eight single-ended ADC Channels can be accomplished only if the AMUX Buses are not being used for other funcitonality (e.g. CapSense). If
the AMUX Buses are being used for other functions, then the maximum number of single-ended ADC channels is six. Similarly, if the AMUX Buses are being
used for other functionality, then the maximum number of differential ADC channels is three.