CPU_45B-V1
CPU Board XMC4500 SDRAM
Hardware Description
Board User's Manual
11
Revision 1.0, 2013-02-20
Hitex PowerScale probe is provided on the CPU_45B-V1 board to measure the power consumption of the
XMC4500 device.
Table 2
Power Measurement
Jumper
Function
Description
JP300
PowerScale
A Hitex PowerScale probe can be connected for current sensing the
VDD3.3 (CPU power source). Default: pos. 1-2 (closed)
Note: On the PCB there is a shorting trace between pin 1-2. This trace has
to be cut first, before using PowerScale. Pin 3 is GND.