background image

  

User guide 

3 of 19 

Revision 1.0  

 

2019-05-07 

 

Demoboard BTS3011TE 

User Manual 

Getting Started 

   

1

 

Getting Started

 

1.1

 

BTS3011TE Shield Overview 

 

The 12V low-side switch demoboard with one BTS3011TE from Infineon Technologies is a flexible evaluation 
board dedicated to drive all kinds of loads up to 1kHz, especially motors and capacitive-like loads. This 
demoboard is compatible with Arduino UNO shield. 

The demoboard can be controlled either with the general logic I/O-ports of a microcontroller or with a PWM 
signal from a waveform generator. It includes typical schematic to control the BTS3011TE. 

This shield offers a quick evaluation of the product functions 

like the “

Status

 latch feedback, dedicated logic 

supply 

(logic is independent of Input) and all protections, e.g. “

Current protection

”, “Over temperature 

protection”

WARNING: Please refer to BTS3011TE datasheet for details on functionalities and parameters values. This 
user manual does not replace the datasheet and user must be aware of limitations before turning on and 
supply

The shield can be easily connected to any Arduino UNO board via headers. Code and GUI is available for 
Arduino UNO. No code/interface is available for XMC1100 but XMC1100 can be easily programmed through 
Arduino IDE: Please check the following link for detail

https://github.com/Infineon/XMC-for-Arduino

 

 

 

Figure 1

 

Example figure 

 

 

Summary of Contents for BTS3011TE

Page 1: ...rted 3 1 1 BTS3011TE Shield Overview 3 1 3 Key Features 4 1 4 Demoboard Package Contents 4 1 5 Typical Connection 4 1 5 1 With Arduino UNO Shield 4 1 5 2 Without Arduino UNO 4 2 Demoboard Configuration 5 2 1 STATUS Pin Connection 5 2 1 1 Overcurrent limitation Short circuit behavior 6 2 1 3 Behavior with overload current below current limitation trigger level 7 3 Software Utilisation 8 3 1 Install...

Page 2: ...User guide 2 of 19 Revision 1 0 2019 05 07 Demoboard BTS3011TE User Manual Getting Started 6 B O M 15 7 Board Layout 16 7 1 TOP 16 7 2 BOTTOM 16 7 3 MECHANICAL VIEW 17 Revision history 18 ...

Page 3: ...ntrol the BTS3011TE This shield offers a quick evaluation of the product functions like the Status latch feedback dedicated logic supply logic is independent of Input and all protections e g Current protection Over temperature protection WARNING Please refer to BTS3011TE datasheet for details on functionalities and parameters values This user manual does not replace the datasheet and user must be ...

Page 4: ... and ON Output voltage Input logic Status and VDD can be measured externaly with test points Input logic Status and VDD can be monitored with Arduino interface 1 4 Demoboard Package Contents In the zip package must be the following files Demoboard_BTS3011TE_User_Manual_V1 0 pdf Demoboard_AIKO_Universal exe Demoboard_AIKO_Universal ino 1 5 Typical Connection 1 5 1 With Arduino UNO Shield Figure 2 E...

Page 5: ... VDD via a Resistor of 10kΩ when jumper connects therminal 1 2 together This pin configuration allows to monitor the STATUS pin reading STATUS voltage and to reset the STATUS signal when latched due to overtemperature event STATUS and reset mechanism are described in detail in the product datasheet BTS3011TE Jumper position b STATUS pin is not needed and is directly connected to GND This pin confi...

Page 6: ...eration low Overtemperature condition 2 1 1 Overcurrent limitation Short circuit behavior If the load current IL reaches the current limitation trigger level IL LIM TRIGGER the device will self limit the current to IL LIM the device will start heating up and will self turn off when junction temperature reaches TJ SD Figure 5 Short circuit protection via current limitation and thermal switch off wi...

Page 7: ...rload current below current limitation trigger level The lower current limitation level IL LIM will be also triggered by a thermal shutdow This could be the case in terms of overload with a current still beliw the current limitation trigger lever IL IL LIM TRIGGER Figure 6 Example of overload behavior with thermal shutdown ...

Page 8: ...niversal ino Arduino code and upload it When the code is correctly uploaded installed the user can plug the demoboard on the Arduino shield The green LED must turn on meaning that BTS3011TE logic is supplied Then launch the Demoboard_Aiko_Universal exe Click on Ports to select the right communication port on your Arduino board Click on Start to start the system If it s not working check your port ...

Page 9: ...tatus should appear in green If BTS3011TE is latched status appears in red 3 2 2 Control Panel Button ON OFF allows the user to switch ON and OFF the BTS3011TE in continuous mode Button Pulse creates a manageable pulse for the BTS3011TE User can set upto 30 pulses with period control adjustable in the PWM Mode User can set an Ending action afer the end of the sequence Button PWM allows user to man...

Page 10: ...S3011TE User Manual Software Utilisation 3 2 4 Alternative Command Panel STATUS pin can be reseted Low to High when Reset Status button is pressed Current limitation threshold can be reset when Reset Trig buttion is pressed Figure 9 Alternative command panel ...

Page 11: ...Table 2 Table A 4 2 Arduino XMC1100 Connectors 4 2 1 Connector SV1 Table 3 Table A Name Connector Type Description OUT J1 Power supply OUT Connector GND J2 Ground power GND Connector Name Connector Type Description 1 Not connected ST 2 I O STATUS pin Low active 3 Not connected IN 4 Digital input To turn the device ON OFF 5 6 Not connected GND 7 Digital Ground Ground 8 to 10 Not connected ...

Page 12: ... Table A 4 2 3 Connector SV3 Table 5 Table A 4 2 4 Connector SV4 Table 6 Table A Name Connector Type Description 1 to 4 Not connected 5V 5 VDD Logic supply GND 6 Digital Ground Ground GND 7 Digital Ground Ground 8 Not connected Name Connector Type Description 1 to 8 Not connected Name Connector Type Description 1 to 6 Not connected ...

Page 13: ...TUS pin SW2 2 Digital input Reset IL LIM _TRIGGER when both SW1 and SW2 are pressed together Name Connector Type Description JP8 1 Therminal connected to VDD 2 Therminal connected to STATUS pin 3 Therminal connected to GND Name Connector Type Description IN 1 Digital input Pin Activation for BTS3011TE STATUS 2 Digital I O Pin to monitor the part status VDD 3 Logic supply Pin to provide supply to B...

Page 14: ...User guide 14 of 19 Revision 1 0 2019 05 07 Demoboard BTS3011TE User Manual Schematic 5 Schematic Figure 11 Example figure ...

Page 15: ...erence Part 1 2 C1 C3 100n 2 1 C2 1n 3 1 D1 RED LED 4 1 D2 GREEN LED 5 1 JP8 HEADER 3 6 2 TP1 J1 OUT 7 2 TP2 J2 GND 8 1 M1 BTS3011TE 9 1 Q1 PMOS1 10 1 Q2 PMOS2 11 2 R1 R2 560 12 1 R3 330 13 1 R4 10k 14 1 R5 100 15 1 R6 1k 16 4 SV1 SV2 SV3 SV4 CONNECTOR EDGE 10 17 2 SW1 SW2 SW_TC_SPST 18 1 TP3 VDD 19 1 TP4 IN 20 1 TP5 STATUS ...

Page 16: ...User guide 16 of 19 Revision 1 0 2019 05 07 Demoboard BTS3011TE User Manual Board Layout 7 Board Layout 7 1 TOP Figure 12 Example figure Body text 7 2 BOTTOM ...

Page 17: ...User guide 17 of 19 Revision 1 0 2019 05 07 Demoboard BTS3011TE User Manual Board Layout Figure 13 xample figure 7 3 MECHANICAL VIEW Figure 14 Example figure 1 ...

Page 18: ...User guide 18 of 19 Revision 1 0 2019 05 07 Demoboard BTS3011TE User Manual Revision history Revision history Document version Date of release Description of changes 1 0 May 7 2019 First release ...

Page 19: ...llectual property rights of any third party with respect to any and all information given in this application note The data contained in this document is exclusively intended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product for the intended application and the completeness of the product information given in this ...

Reviews: