Powersmart 2480 Switch Definitions for Matchbox Wavestream supported
BUCs
The front panel switch control of the iNetVu PowerSmart 2480 fully supports the Matchbox Wavestream
BUC’s.
BUC Status LED’s
Transmit LED
ON indicates BUC is transmitting
OFF indicates BUC is not transmitting
Lock Loss LED
This LED is lit when the up converter losses lock indicating the 10 MHz
reference on the IFL is not present, the signal level is too low or is frequency
unstable.
Over Temp LED
Unit temperature has exceeded its internal cutoff. Power to the internal amplifier
module is cut off automatically if the internal temperature reaches a point
where the amplifier might be damaged
.
Sum Fault LED
This LED is lit when there is a critical fault with the internal amplifier
BUC CONTROL SWITCHES
TRANSMIT
Enables/Disables the Transmit
BUC LED
Activates/Deactivates the LED’s on the BUC
POWER SWITCH
The power switch supplies DC power to the BUC.
JUMPER CONFIGURATION
Jumpers Added
enables RS485
Interface
These jumpers
are used to set
LED Hi/Low
status on front
panel.