![Inepro Multi Connectivity Box Manual Download Page 7](http://html1.mh-extra.com/html/inepro/multi-connectivity-box/multi-connectivity-box_manual_2054650007.webp)
Installation
Hardware
Page 3 of 20
Multi Connectivity Box | EN
On the left the 4 glands, depicted blue here. These feature the 4 inputs and outputs, each gland has 1
relay and 1 feedback wire.
The gland depicted here with a big grey cable supplies the 220V Main power. Finally the gland depicted
here with a black cable has the network cable.
In use function
The
input (green & yellow wire)
can be used
(you must short the two wires
) to indicate to the
SmartConnector
that the device (for example the washing machine) is in use
.
In that case usage is prevented and no pulse will be send.
The
output (Brown and white wire)
are connected in the lower-left corner. These signal the device with
a pulse to start running.
Read more about 'Connection to I/O modules' here:
Appendix I: Connection to I/O modules