![Inepro Multi Connectivity Box Manual Download Page 6](http://html1.mh-extra.com/html/inepro/multi-connectivity-box/multi-connectivity-box_manual_2054650006.webp)
Installation
Hardware
Page 2 of 20
Multi Connectivity Box | EN
Hardware
You can connect 1 through 4 devices, each will have two
Output wires (brown and white)
, those will
output a signal, when the device should start (is reserved, and / or paid for). In these examples the white
and brown wires are used for the Output signal. Each device will also have the possibility to connect an
(optional) input wire, that is used as a signal that the device is busy.
In these examples the yellow and
green wires are used for this input (aka busy signal)
.
Communication
The communication with the I/O Module uses 38400 BAUD 8n1, no parity. The address = 0x82.
In the I/O module DIP switch 1 is (and must be) set to ON.
In this example Output 1 & 2 and Input 1 & 2 are connected.
Note: This application can only use a single I/O module, it can not be used in a chain with
multiple I/O modules!