background image

02-217/2016 Rev.0

RFSAI-161B

Automatic light control

EN

Made in Czech Republic

U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected] 

U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected] 

 

EN

 Support: +381 63 479 880 | 

RS

Tehnička podrška +381 63 479 880

 www.elkoep.rs

Technical parameters  /

* Control button input is at the supply voltage potential.

Attention:

When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.

Between the individual commands must be an interval of at least 1s.

4 / 4

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-

lation and connection can be carried out only by a person with adequate professional qualification upon under-

standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free 

function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, 

deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat 

this product and its parts as electronic waste after its lifetime is terminated.  Before starting installation, make sure 

that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-

tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch 

parts of the device that are energized – life threat.  Due to transmissivity of RF signal, observe correct location of 

RF components in a building where the installation is taking place. RF Control is designated only for mounting in 

interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into 

metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.  

RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-

fered, battery of can get flat etc. and thus disable remote control. 

Warning

Supply voltage:
Apparent power:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. switching power DC:
Insulation voltage between
relay outputs and internal circuits:
Isolates. voltage open relay
contact:
Mechanical service life:
Electrical service life (AC1):
Indication of relay switch:
Controlling
RF command from the detector:
Manual control:
External button:
Range in open space:
Other data
Open contact voltage external 
switch:
Resistor for the management of 
external switch:
Resist. of connection for open 
contact:
Galvanic isolation of input:
Operating temperature:
Storage temperature:
Working position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Terminals:
Terminals (CY wire, Cross-section):
Terminal length:
Dimensions:
Weight:

Prekidačka jedinica sa ulazom za postojeći prekidač

RS

Napon napajanja:
Prividna snaga:
Maksimalna potrošnja:
Tolerancija napajanja:
Izlaz
Broj kontakata:
Nominalna struja:
Prekidačka snaga:
Maksimalna snaga:
Prekidački napon:
Min. preklopna snaga

Napon izolacije između relejnih 
izlaza i integrisanih kola:

Izolacija kontakta za napon
otvorenog releja:
Mehanički radni vek:
Električni radni vek (AC1):
Indikacija relejnog prekidača:
Kontorla
Frekvencija:
Ručna kontrola:
Spoljni taster:
Domet:
Osatli podaci
Spoljni prekidač napona 
otvorenog kontakta:
Odpor na vedení pro externí
spínač:
Otpor za upravljanje spoljnim 
prekidačem:
Galvanska izolacija ulaza:
Radna temperatura:
Temperatura skladištenja:
Pozicija rada:
Montaža:
Stepen zaštite:
Kategorija prenapona:
Stepen zagađenja:
Terminali:

Terminali (CY žice, poprečni presek):

Dužina terminala:
Dimenzije:
Težina:

     

230 V AC / 50-60 Hz                120 V AC / 60 Hz                     12-24 V DC / AC 50-60 Hz

                     9 VA                                              9 VA                                                  -

0.7 W

+10 %; -15 %

1x switching / prelaz (AgSnO

2

)

12 A / AC1

3000 VA / AC1, 288 W / DC

30 A, max. 4 s at /na 10% 

250 V AC1 / 24 V DC

100 mA / 10 V

basic Insulation (Cat. III surges by EN 60664-1) /

osnovna izolacija (III kategorija prenapona prema EN 60664-1)

1 kV

3x10

7

5x10

4

red / crvena LED

866 MHz, 868 MHz, 916 MHz

button / taster PROG (ON/OFF)

cable lenght / dužina kabla maks. 12 m *

up to / do 160 m

3 V

<1 kΩ

>10 kΩ

no / ne

-15 ... + 50 °C
-30 ... + 70 °C

any / bilo gde

free at lead-in wires / labav na dovodnim žicama

IP30

III.

2

0.5 - 1 mm

2

2x 0.75, 2x 2.5 mm

2

90 mm

49 x 49 x 21 mm

50 g

* Ulaz kontrolnog tastera je na potencijalu mrežnog napona. 

Upozorenje:

Kada instalirate iNELS RF Control sistem,  mora se poštovati minimalno rastojanje od 1cm između 

pojedinih elemenata.

Između pojedinačnih komandi potrebno je da prođe interval od 1s.

Uputstva za upotrebu su namenjena za ugradnju kao i za korisnike proizvoda. Uputstva se uvek dobijaju uz 

proizvod. Instalaciju i povezivanje smeju da obavljaju samo kvalifikovane osobe, u skladu sa svim važećim 

propisima, koja je detaljno upoznata sa ovim uputstvom i funkcijama komponenti. Funkcija elemenata takođe 

zavisi od prethodnog načina transporta, skladištenja i rukovanja. Ako u bilo kom slučaju primetite nekakve 

znakove oštećenja, deformacije, kvara ili ako neki deo nedostaje, nemojte ugrađivati uređaj, prijavite to pro-

davcu. Nakon što kopmonenti istekle životni vek, potrebno je tretirati je kao elektronski otpad. Pre započinja-

nja instalacije potrebno je prvo se uveriti da su žice, povezani delovi ili terminali bez napona. Tokom instalacije 

i održavanja  moraju se poštovati sigurnosni propisi, standardi, direktive i profesionalne odredbe za rad sa 

električnom opremom. Ne dodirujte elemente pod naponom golim rukama, zbog mogućnosti stujnog udara i 

rizika od smrti.  Zbog propustljivosti RF signala, obratiti pažnju na pravilno postavljanje RF elemenata u zgradi-

gde će se izvoditi ugradnja. RF kontrola je namenjena samo za unutrašnju ugradnju. Elementi nisu namenjeni 

za spoljašnju ugradnju kao i za ugradnju u vlažne prostorije, ne smeju se ugraditi u metalne ormane kao ni 

u plastične ormane sa metalnim vratima iz razloga što će to sprečiti prenos radio frekvencijskog signala. RF 

konrola se ne prepuručuje za kontrolu uređaja koji pružaju životne funkcije kao i za kontrolu opasne opreme 

kao što su  pumpe, električni grejači bez termostata, liftova, dizalica itd. iz razloga što prenos radio frekvencije 

može biti preklopnjen, ometen, baterija predajnika se može isprazniti i na taj način daljinski upravljač može 

biti onemogućen.

Upozorenje

Tehnički parametri

Summary of Contents for RFSAI-161B

Page 1: ...rious construction materials 60 90 80 95 20 60 0 10 80 90 brickwalls wooden structures with plaster boards reinforced concrete metalpartitions commonglass RFRP 20 For more information see Installation manual iNELS RF Control http www elkoep com catalogs and brochures Prekidačka jedinica sa ulazom za postojeći prekidač RS plafonska montaža instalacija u instalacioni okvir čak i pod postojećim dugme...

Page 2: ...ay the PIR detector and external input are disabled Permanently if the RFMD 100 PIR detector detects movement closing the external input RelayclosingisblockedbypreviouspressingofMASTER OFFbutton Tounlock pressbuttons 1 2 or 3 on the assigned remote control Prekidačka jedinica sa ulazom za postojeći prekidač RS TIME fino podešavanje vremena podešavanje vremena unutar izabranog bruto vremenskog inte...

Page 3: ...econds deletionoc curs of the actuator s entire memory LED flashs 4x in each 1s interval Theactuatorgoesintotheprogrammingmode theLEDflashesin0 5sintervals max 4min YoucanreturntotheoperatingmodebypressingtheProgbutton for less than 1s PROG 8s 1 x Prekidačka jedinica sa ulazom za postojeći prekidač RS Izvadite bateriju iz detektora Pritiskom na taster za progra miranje na aktuatoru tokom 5 sekundi...

Page 4: ...čki napon Min preklopna snaga Napon izolacije između relejnih izlaza i integrisanih kola Izolacija kontakta za napon otvorenog releja Mehanički radni vek Električni radni vek AC1 Indikacija relejnog prekidača Kontorla Frekvencija Ručna kontrola Spoljni taster Domet Osatli podaci Spoljni prekidač napona otvorenog kontakta Odpor na vedení pro externí spínač Otpor za upravljanje spoljnim prekidačem G...

Reviews: