background image

3 / 4

UPLINK

DOWNLINK

UPLINK / DOWNLINK

Note

Graf

Byte

0-14

15

16

17

18

19

20

21

Bit

7

6

5

4

3

2

1

0

S0

IMEI

0x01 - 

notifi cation

0x02 - 

heartbeat

0x01

Reserved for future use

Tamper: 

1 - opened

0 - closed

Battery: 

1 - low level

0 - OK

Counter[0]

Counter[1]

Counter[2]

Counter[3]

ENERGY_METERING

0x02

Counter[0]

Counter[1]

Counter[2]

Counter[3]

Function

Function

0

1

2

3

4

5

6

7

S0

0x01

Heartbeat period

0x00

0x00

Threshold 1H

Threshold 1L

Threshold 2H

Threshold 2L

ENERGY_METERING

0x02

Heartbeat period

0x00

0x00

Threshold 1H

Threshold 1L

0x00

0x00

Heartbeat period

0 - 127 [x min]

heartbeat message period

128 - 255 [(x - 127) h]

Threshold 1H 1L

0 - 65535

Input 1 - pulses threshold

Threshold 2H 2L

0 - 65535

Input 2 - pulses threshold

Name

Unit

Example

Counter [0 – 3]

pulse

Counter[0] = 0x01
Counter[1] = 0x02
Counter[2] = 0x03
Counter[3] = 0x04

Counter = 0x01020304

= 16909060 pulses

Summary of Contents for Elko AirTM-100NB

Page 1: ... operation of individual devices The NarrowBand network is available to use this standard Information about the NarrowBand network The network provides two way communication and the only one to use the licensed LTE band Our devices allow band 1 2100MHz Band 3 1800MHz Band 8 900MHz Band 5 850MHz Band 20 800MHz and Band 28 700MHz It uses this SIM card technology for each device The advantage of Narr...

Page 2: ...ries in water or fire Do not dismantle batteries do not try to charge them and protect them from extreme heating danger of leakage Upon contact with acid immediately rinse the affected area with a stream of water and seek medical attention Keep batteries out of the reach of children If it is suspected that the battery has been swallowed or somehow placed inside the body consult a doctor immediatel...

Page 3: ...unter 3 Function Function 0 1 2 3 4 5 6 7 S0 0x01 Heartbeat period 0x00 0x00 Threshold 1H Threshold 1L Threshold 2H Threshold 2L ENERGY_METERING 0x02 Heartbeat period 0x00 0x00 Threshold 1H Threshold 1L 0x00 0x00 Heartbeat period 0 127 x min heartbeat message period 128 255 x 127 h Threshold 1H 1L 0 65535 Input 1 pulses threshold Threshold 2H 2L 0 65535 Input 2 pulses threshold Name Unit Example C...

Page 4: ...plastic cabinets with metal doors this prevents transmission of the radio frequency signal iNELS Air is not recommended for control ling life saving instruments or for controlling hazardous devices such as pumps heaters without thermostat lifts hoists etc radio frequency transmission may be overshad owed by obstruction interference transmitter battery may be discharged etc thereby disabling the re...

Reviews: